HOME
ESR
EXPERIMENTS
LABS etc
E121
E127
E132
E125
E143
laser_cooling_2021
E142
Ê128
E146
E0052
E0018
E0028
E0038
proton-capture on 118Te, Page 17 of 29
Not logged in
Find
|
Login
|
Help
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Category --
Analysis
Calibration
DAQ
General
Collaboration
Runs
Detectors
Simulations
Accelerator
572 Entries
Goto page
Previous
1
,
2
,
3
...
16
, 17,
18
...
27
,
28
,
29
Next
ID
Date
Author
Category
Subject
Year
Text
106
Sat Mar 21 06:02:22 2020
Tino, Oliver
General
Detector filling
Run stopped for detector fillings
115
Sat Mar 21 10:20:27 2020
Ragan, Alex
General
Target LN2
The LN2 Dewar on the ESR roof has been refilled.
119
Sat Mar 21 11:30:04 2020
Laszlo
General
MWPC movement
now we try to move the capture detector (MWPC
in the 1. dipol before our Si setup) inside
the ring while the DAQ was ON
122
Sat Mar 21 12:02:57 2020
Ragan, Laszlo
General
run entry - run061
12:02 pm - scapper is taken out completely
open file : runstart061
123
Sat Mar 21 12:06:50 2020
Laszlo
General
run61 - SCRAPER moved out
we want to see any change on the Silicon count
rate, because we will have now also Rutherford
scattering.
125
Sat Mar 21 12:32:00 2020
Laszlo
General
Estimated target thickness
Target thickness must be like 5mm (was measured
with a moving thin wire)
The beam thickness is small because of the
126
Sat Mar 21 12:42:21 2020
Ragan
General
Entry to ESR for MCP detector
Pierre Michel and Laszlo go inside the ESR
for switching on the MCP detector so that
the photons from the gas jet and secondary
130
Sat Mar 21 14:52:05 2020
Laszlo
General
target optimization
previous position of the beam at target was
-3mm (for the night position)
max. intensity position of the beam at target
133
Sat Mar 21 15:26:49 2020
Laszlo
General
SCRAPER is ON use again
Yuri puts back the scraper (Egelhof 1 - GE01DD1IG)
into position = +19. (where it was in the
evening)
134
Sat Mar 21 15:30:34 2020
Sergiy
General
go into the ESR
We are going into the ESR to check the electronics.
Use calibration sources (133Ba etc).
135
Sat Mar 21 17:21:57 2020
Laszlo
General
new Target density
Ulli and Nikos managed to set the target density
to ~7E13 at 51K temperature
138
Sat Mar 21 17:34:10 2020
Sergiy
General
Recoils
We started recording the data from the recoils
using the MCP from Pierre-Michael's experiment.
140
Sat Mar 21 18:13:22 2020
Shahab
General
rough comparison gas target off and on
rough comparison of life time at 10 MeV/u
when target off with on. more noise in background
means weaker signal.
151
Sat Mar 21 23:07:00 2020
Laszlo
General
1672. MCP file was (recoils) was not closed
1672. MCP file was (recoils) was not closed
when we refilled the Xrays and did the cable
change of 90 and 145 xrays
177
Sun Mar 22 10:05:37 2020
Esther, Ragan
General
run entry - run079
The intensity of beam from SIS is less due
to some issues with UNILAc.
179
Sun Mar 22 10:28:27 2020
Esther, Ragan
General
run entry - run079
The problem at UNILAC seems to have solved
itself. Intensity is returning to normal.
183
Sun Mar 22 12:01:44 2020
Esther, Ragan
General
Vacuum problem with SIS
There is some problem with the vacuum in SIS
and thus data recording is stopped.
186
Sun Mar 22 12:53:43 2020
Laszlo
General
quick summary for the 118Te overnight measurement
Quoting Yury:
"The count rate is very low. We estimate
that we store about 10^4 118Te particles
188
Sun Mar 22 13:33:19 2020
Laszlo
General
2nd storage of MCP data
I made a backup for the MCP data on my own
GSI laptop. Looking for better solution...
the original "fresh" files stored at litv-exp@lxg1299:/data.local2/hillenbrand/Laszlo/
191
Sun Mar 22 14:58:59 2020
Laszlo
General
dropping density of Gasjet
after like 20min run, the density of the gasjet
already dropped from 10^14 to 8.7*10^13.
Now it seems to remain in that value
Goto page
Previous
1
,
2
,
3
...
16
, 17,
18
...
27
,
28
,
29
Next
ELOG V3.1.5-fc6679b