Text
339
Fri May 14 10:28:49 2021
Jan Glorius
Calibration
run0042 - Xray145 calib 241Am_hi d=305mm
2021
Efficiency calibration in the lab
************************************
340
Fri May 14 11:17:48 2021
Jan Glorius
Calibration
run0043 - Xray145 calib 210Pb d=305mm
2021
Efficiency calibration in the lab
************************************
341
Fri May 14 13:58:52 2021
Jan Glorius
Calibration
run0044 - Xray145 calib 210Pb d=305mm
2021
Efficiency calibration in the lab
************************************
342
Sat May 15 20:21:59 2021
Jan Glorius
Calibration
run0045 - Si pulser run
2021
Detector: DSSD
Source: CAEN Detector Emulator
343
Sun May 16 11:25:25 2021
Jan Glorius
Calibration
run0046 - Xray E-calib 241Am all dets
2021
Detectors: Xray1 (GEM1800), Xray2 (GLP), Xray3
(GEM3000)
Sources: different Am241 at each detector
344
Sun May 16 11:54:12 2021
Jan Glorius
Calibration
Xray performance in lab
2021
These are the current Xray detector performances
in the lab using data from run0046
347
Tue May 18 01:03:59 2021
Jan Glorius
Calibration
run0048 - calib all Xray det.
2021
Efficiency calibration in ESR
************************************
348
Tue May 18 01:21:27 2021
Jan Glorius
Calibration
run0047 - crap
2021
349
Tue May 18 11:22:57 2021
Jan Glorius
Calibration
run0049 - calib all Xray det.
2021
Efficiency calibration in ESR
************************************
355
Thu May 20 15:15:54 2021
Beatriz, Laszlo
Calibration
run0050
2021
crap
356
Thu May 20 17:31:28 2021
Beatriz, Laszlo
Calibration
run0051
2021
crap
462
Wed May 26 07:08:07 2021
Laszlo
Calibration
quick and dirty calibration coefficients for the Si channels
2021
The coefficients are produced only quick and
dirty, S_x=1 was fixed to 1.
E = E_x = E_y = S_x*A_x = S_y*A_y
563
Sun May 30 10:24:20 2021
Jan Glorius
Calibration
run0212 - X-calib. 90-pb 145-am
2021
Efficiency calibration in ESR after experiment
************************************
564
Sun May 30 11:32:06 2021
Jan Glorius
Calibration
run0213 - X-calib. 90-am 145-pb 35-ba
2021
Efficiency calibration in ESR after experiment
************************************
565
Sun May 30 13:23:26 2021
Jan Glorius
Calibration
run0214 - X-calib. 90-ba 145-ba 35-am
2021
Efficiency calibration in ESR after experiment
************************************
566
Sun May 30 14:38:09 2021
Jan Glorius
Calibration
run0216 - X-calib. 90-ba 35-pb
2021
Efficiency calibration in ESR after experiment
************************************
568
Sun May 30 14:48:09 2021
Jan, Sophia
Calibration
run0215 - crap
2021
570
Mon May 31 14:38:33 2021
Sophia
Calibration
Runlist for X-ray detector calibrations after the experiment
2021
The by Jacobus Swartz created table in entry
335 extended by the calibration after the
experiment.
573
Wed Jun 23 12:29:35 2021
Jan, Sophia
Calibration
Efficiency of the x-ray Detectors
2021
For the x-ray detectors, efficiencies have
been measured, before and after the experiment
was performed.
575
Thu Jul 8 13:39:34 2021
Jan
Calibration
Electron cooler parameters
2021
Below are the results from the e-cooler voltage
offset measurments done by Regina Hess et
al. using the voltage divider (VD).