Mon Mar 23 12:30:39 2020, laszlo, Analysis, with and without scraper,
|
|
Thu May 27 12:41:25 2021, Yuri, Jan, Runs, Run 0152, 2021
|
No. of stacks: 10
length SC10: 2x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -12.8 mm
open file : e127b_run0152.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +2.0 mm
run start: 12:39:21 27.05.2021
run stop: 13:23:57 27.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 3 Hz
Xray_ON_bdt: 90 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.5e9 (one shoot)
ESR current at injection: 2.0e6 (stacked)
ESR particles after decel.: Unreadable
Target ON density: 1.0e14 |
Thu May 27 13:24:29 2021, Yuri, Jan, Runs, Run 0153, 2021
|
All runs before (since 13:40 26/05/21) were taken without the degrader in FRS!
No. of stacks: 10
length SC10: 2x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -12.8 mm
open file : e127b_run0153.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +2.0 mm
run start: 13:23:57 27.05.2021
run stop: 13:31:44 27.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 3 Hz
Xray_ON_bdt: 90 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.5e9 (one shoot)
ESR current at injection: 2.0e6 (stacked)
ESR particles after decel.: Unreadable
Target ON density: 1.0e14 |
Thu May 27 14:38:14 2021, Yuri, Jan, Runs, Run 0155, 2021
|
No. of stacks: 10
length SC10: 2x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -12.8 mm
open file : e127b_run0155.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +2.0 mm
run start: 14:38:00 27.05.2021
run stop: 15:11:15 27.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 3 Hz
Xray_ON_bdt: 90 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.5e9 (one shoot)
ESR current at injection: 2.0e6 (stacked)
ESR particles after decel.: Unreadable
Target ON density: 1.0e14 |
Thu May 27 11:36:23 2021, Yuri, Beatriz, Jan, Runs, Run 0151, 2021
|
Power supplies for correction coils were in failure.
No effect seen in schottky after reset and repower, however.
No. of stacks: 10 (switched to 20 shortly)
length SC10: 2x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -12.8 mm
open file : e127b_run0151.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +2.0 mm
run start: 11:36:01 27.05.2021
run stop: 12:39:18 27.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 3 Hz
Xray_ON_bdt: 90 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.5e9 (one shoot)
ESR current at injection: 2.0e6 (stacked)
ESR particles after decel.: Unreadable
Target ON density: 1.0e14 |
Thu May 27 08:23:05 2021, Yuri, Beatriz, Runs, Run 0148, 2021
|
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -11.5 mm
open file : e127b_run0148.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +2.0 mm
run start: 08:22:28 27.05.2021
run stop: 09:38:31 27.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 3 Hz
Xray_ON_bdt: 100 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.6e9 (one shoot)
ESR current at injection: 4.6e6 (stacked)
ESR particles after decel.: Unreadable
Target ON density: 1.0e14
Beam was off for a few minutes, after coming back the number of particles was reduced for a few minutes and then increased to the values at the beginning of the run. |
Thu May 27 08:26:15 2021, Yuri, Beatriz, General, Optimisation beam position on target and scraper position, 2021
|
Optimised overlap with the target by shifting the beam from -11.5 to 12.8 mm. This lead to an increase of the DSSSD rate of a factor between 2.5 or 3.
Adjusted scraper position by looking at x-ray rate and move it from +1 to +2. |
Thu May 27 09:39:15 2021, Yuri, Beatriz, Runs, Run 0149, 2021
|
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -12.8 mm
open file : e127b_run0149.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +2.0 mm
run start: 09:38:49 27.05.2021
run stop: 10:09:21 27.05.2021 (stopped for filling det.)
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 3 Hz
Xray_ON_bdt: 100 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.6e9 (one shoot)
ESR current at injection: 2.0e6 (stacked)
ESR particles after decel.: Unreadable
Target ON density: 1.0e14 |
Thu May 27 10:21:41 2021, Yuri, Beatriz, Runs, Run 0150, 2021
|
No. of stacks: 10
length SC10: 2x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -12.8 mm
open file : e127b_run0150.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +2.0 mm
run start: 10:21:17 27.05.2021
run stop: 11:35:36 27.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 5 Hz
Xray_ON_bdt: 80 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.6e9 (one shoot)
ESR current at injection: 2.0e6 (stacked)
ESR particles after decel.: Unreadable
Target ON density: 1.0e14 |
Wed May 19 19:47:14 2021, Yuri, General, Beam Halflife at 30 AMeV, 2021
|
|
Mon Jul 8 14:57:07 2019, Yuanming Xing, Detectors, The measurement of the tilting angle,
|
As shown in the figure, the detector is tilted by a certain angle which is about 45 degree.
The tilted angle is defined as angle B.
We measured angle A using the vertical laser line (red) and papers with a straight line edge. So we can marked
the line denoted by the laser line when the paper is put on the holder.
In the beginning, the angle A is measured as 43.3±0.5 degree. So angle B= 46.7±0.5 degree
After the adjustment of the detector (to make it in the center of the chamber), the angle A is measured as
43.1±0.5 degree with another paper. So angle B= 46.9±0.5 degree. |
Tue Jul 9 15:26:59 2019, Yuanming Xing, Simulations, Simulated Rutherford scattering distribution on detector,
|
Simulated Rutherford scattering distribution on detector
Beam: 111Sn
Luminosity: 3.08 /mb/s
Distance between the detector and central orbit: 2.80cm
Particle Number in the simulation: 5 Million
Beam quality used in MOCADI input file:
4,
0.27386, 0.182573, 0, -4.0, 0
4,
0.131477, 0.383186, 0, 0.0, 0
1,
0.02, 0, 0, 0.0, 0
1. Beam Energy: 6MeV/u
2. Beam Energy: 7MeV/u
3. Beam Energy: 8MeV/u |
Sat May 29 13:43:39 2021, Tino, Rene, Yuri, Laszlo, Markus, Runs, change of settings, 2021
|
from now on, everal beam setting will be different. We could not get the beam back to were it was before. When the scraper was pulled back by 2 cm, the loe/energy beam was visible again via cap.
Schottky. However, no x-rays could be observerved during the target-on phase.
Hence the interpretation:
beam position has change at least a few mm, at most 2 cm.
Will now try to get a new overlap with target and need to adjust the detector position too.
All online - Si spectra are cleared. |
Sat Mar 21 03:01:22 2020, Tino, Oliver, Runs, run entry - run051,
|
Open file: runstart051
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 01:59 , first file: run051_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 03:01 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 3 Hz
Xray_90: 23 Hz
Xray_145: 18 Hz
BaF_OR: - Hz
Si voltage: 60.02 V
Si leakage current: 3.99 uA
SIS particles before: 2.3e9
ESR particles at injection: estimated ~10^5 - 10^4
ESR particles after decel.:
Target ON density: 1.24e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 03:03:53 2020, Tino, Oliver, Runs, run entry - run052,
|
Open file: runstart052
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 03:03 , first file: run052_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 03:03 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 1 Hz
Xray_90: 19 Hz
Xray_145: 26 Hz
BaF_OR: - Hz
Si voltage: 60.02 V
Si leakage current: 3.99 uA
SIS particles before: 2.3e9
ESR particles at injection: estimated ~10^5 - 10^4
ESR particles after decel.:
Target ON density: 1.22e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 03:30:21 2020, Tino, Oliver, Runs, run entry - run052,
|
Open file: runstart052
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 03:03 , first file: run052_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 03:30 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 0 Hz
Xray_90: 22 Hz
Xray_145: 14 Hz
BaF_OR: - Hz
Si voltage: 60.02 V
Si leakage current: 3.98 uA
SIS particles before: 2.5e9
ESR particles at injection: estimated ~10^5 - 10^4
ESR particles after decel.:
Target ON density: 1.23e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 03:58:56 2020, Tino, Oliver, Runs, run entry - run053,
|
Open file: runstart053
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 03:03 , first file: run053_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 03:58 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 1 Hz
Xray_90: 21 Hz
Xray_145: 21 Hz
BaF_OR: - Hz
Si voltage: 60.02 V
Si leakage current: 3.96 uA
SIS particles before: 2.5e9
ESR particles at injection: estimated ~10^5 - 10^4
ESR particles after decel.:
Target ON density: 1.16e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 04:29:59 2020, Tino, Oliver, Runs, run entry - run053,
|
Open file: runstart053
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 03:03 , first file: run053_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 04:30 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 0 Hz
Xray_90: 27 Hz
Xray_145: 17 Hz
BaF_OR: - Hz
Si voltage: 60.01 V
Si leakage current: 4.03 uA
SIS particles before: 2.4e9
ESR particles at injection: estimated ~10^5 - 10^4
ESR particles after decel.:
Target ON density: 1.40e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 05:01:09 2020, Tino, Oliver, Runs, run entry - run054,
|
Open file: runstart054
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 05:00 , first file: run054_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 05:00 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 0 Hz
Xray_90: 19 Hz
Xray_145: 23 Hz
BaF_OR: - Hz
Si voltage: 60.01 V
Si leakage current: 3.98 uA
SIS particles before: 2.4e9
ESR particles at injection: estimated ~10^5 - 10^4
ESR particles after decel.:
Target ON density: 1.34e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 05:29:17 2020, Tino, Oliver, Runs, run entry - run054,
|
Open file: runstart054
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 05:00 , first file: run054_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 05:29 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 1 Hz
Xray_90: 25 Hz
Xray_145: 15 Hz
BaF_OR: - Hz
Si voltage: 60.02 V
Si leakage current: 3.98 uA
SIS particles before: 2.4e9
ESR particles at injection: estimated ~10^5 - 10^4
ESR particles after decel.:
Target ON density: 1.31e13
copy and repeat the above (below the line) every 30 minutes |
|