HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038
  proton-capture on 118Te, Page 25 of 29  Not logged in ELOG logo
ID Date Author Categorydown Subject Year Text Attachments
  296   Fri Apr 30 09:57:57 2021 Jan GloriusCalibrationrun0005 - Xray90 calib Pb210 d=167.5mm 2021Efficiency calibration in the lab

Detector: GEM1800 - 90 deg
  
  298   Fri Apr 30 11:04:31 2021 Jan GloriusCalibrationrun0006 - Xray90 calib Pb210 d=167.5mm 2021Efficiency calibration in the lab

Detector: GEM1800 - 90 deg
  
  299   Fri Apr 30 13:07:23 2021 Jan GloriusCalibrationrun0008 - Xray90 calib Pb210 d=167.5mm 2021Efficiency calibration in the lab

Detector: GEM1800 - 90 deg
  
  300   Fri Apr 30 13:10:44 2021 Jan GloriusCalibrationrun0007 - crap2021crap run   
  301   Fri Apr 30 13:56:59 2021 Jan GloriusCalibrationrun0009 - Xray90 calib Am241 d=167.5mm 2021Efficiency calibration in the lab

Detector: GEM1800 - 90 deg
  
  302   Fri Apr 30 14:35:11 2021 Jan GloriusCalibrationrun0010 - Xray90 calib Ba133 d=167.5mm 2021Efficiency calibration in the lab

Detector: GEM1800 - 90 deg
  
  303   Fri Apr 30 14:48:01 2021 Jan GloriusCalibrationrun0011 - Xray90 calib Ba133_low d=167.5mm 2021Efficiency calibration in the lab

Detector: GEM1800 - 90 deg
  
  304   Sat May 1 22:34:16 2021 Jan GloriusCalibrationefficiency xray 90deg2021the attached efficiency curve for the 90 deg.
xray detector is made with the runs
e127b_run0008.lmd
 90deg_eff.png90deg_eff.dat 
  305   Mon May 3 14:55:44 2021 Jan GloriusCalibrationXray energy calib. table2021Here is the table of energy calibration lines
from Am241 for all Xray detectors for several
measurements.
  
  306   Tue May 4 14:31:51 2021 Jan GloriusCalibrationrun0012 - Xray35 calib Am241_hi d=334mm2021Efficiency calibration in the lab

Detector: GLP2000 - 35 deg
  
  308   Tue May 4 14:46:15 2021 Jan GloriusCalibrationrun0013 - Xray35 calib Am241_hi d=334mm2021Efficiency calibration in the lab

Detector: GLP2000 - 35 deg
  
  309   Tue May 4 16:04:42 2021 Jan GloriusCalibrationrun0014 - Xray35 calib Am241_hi d=334mm2021Efficiency calibration in the lab

Detector: GLP2000 - 35 deg
  
  310   Tue May 4 21:18:15 2021 Jan GloriusCalibrationrun0015 - Xray35 calib Am241_hi d=334mm2021Efficiency calibration in the lab

Detector: GLP2000 - 35 deg
  
  311   Wed May 5 10:02:27 2021 Jan GloriusCalibrationrun0016 - Xray35 calib Ba133_hi d=334mm2021Efficiency calibration in the lab

Detector: GLP2000 - 35 deg
  
  312   Wed May 5 14:24:57 2021 Jan GloriusCalibrationrun0018 - Xray35 calib Pb210 d=334mm2021Efficiency calibration in the lab

Detector: GLP2000 - 35 deg
  
  313   Wed May 5 14:29:02 2021 Jan GloriusCalibrationrun0017 crap run2021    
  314   Wed May 5 21:22:27 2021 Jan GloriusCalibrationrun0019 - Xray35 calib Pb210 d=334mm2021Efficiency calibration in the lab

Detector: GLP2000 - 35 deg
  
  315   Thu May 6 09:40:37 2021 Jan GloriusCalibrationrun0020 - Xray35 calib Ba133_hi d=334mm2021Efficiency calibration in the lab

Detector: GLP2000 - 35 deg
  
  317   Thu May 6 13:39:02 2021 Jan GloriusCalibrationefficiency xray 35deg2021the attached efficiency curve for the 35 deg.
xray detector is made with the runs
e127b_run0015.lmd
 35deg_eff.png35deg_eff.dat 
  318   Thu May 6 14:30:35 2021 Jan GloriusCalibrationrun0021 - Xray35 calib Pb210 d=334mm2021Efficiency calibration in the lab

Detector: GLP2000 - 35 deg
  
ELOG V3.1.5-fc6679b