  219  
 | 
Mon Mar 23 03:53:41 2020 | 
Shahab | Runs | Reduced intensity inspite of faulty kicker |   | SIS Kicker is still faulty. but we managed 
to reduce again the intensity to around 2e6 
particles in ring to reduce scattering on | 
   | 
| 
  138  
 | 
Sat Mar 21 17:34:10 2020 | 
Sergiy | General | Recoils |   | 
 
We started recording the data from the recoils 
using the MCP from Pierre-Michael's experiment. | 
   | 
| 
  129  
 | 
Sat Mar 21 13:44:16 2020 | 
Pierre-Michel | Detectors | Recoil detector |   | We turn on Recoil detector, to use it as a 
monitor for target overlap.
 
 | 
    | 
| 
  212  
 | 
Mon Mar 23 00:39:52 2020 | 
Shahab | General | Ramping cycle picture and data |   | Complete ramping cycle recorded from Oscilloscope 
Tektronix MSOX2024A.
 
 Stored as XLS file. | 
     | 
| 
  450  
 | 
Tue May 25 18:46:04 2021 | 
Robert/Shahab | Accelerator | Quadrupoles down | 2021 | All quadrupoles went off, waiting for the 
on-call service | 
   | 
| 
  11  
 | 
Fri Jun  7 14:39:36 2019 | 
Jan | Detectors | Pt100 installation & readout |   | The new detector holder incorporates a Pt100 
temperature sensor, which is UHV compatible. 
The Pt-resistor is read out via 4 wires. | 
     | 
| 
  1  
 | 
Thu Sep 13 11:42:33 2018 | 
Jan Glorius | Collaboration | Proposal |   | Attached is the beam time proposal submitted 
and accepted by the G-PAC in 2017. 	   | 
     | 
| 
  224  
 | 
Mon Mar 23 06:20:06 2020 | 
Shahab | Runs | Position on scintillator corrected sitll no beam in ESR |   | position on the scintillator was corrected 
by the OPs to center, but beam is still not 
in ESR. | 
    | 
| 
  265  
 | 
Tue Mar 24 10:20:26 2020 | 
Laszlo | Calibration | Pictures of the xray calibration |   |   | 
       | 
| 
  474  
 | 
Wed May 26 18:37:34 2021 | 
Ragan, Thanassis | General | Optimization target bump/overlapp | 2021 | | bump position | X ray bdt ON | Si rate ON 
|
 
---------------------------------------------
 | 
   | 
| 
  490  
 | 
Thu May 27 08:26:15 2021 | 
Yuri, Beatriz | General | Optimisation beam position on target and scraper position | 2021 | Optimised overlap with the target by shifting 
the beam from -11.5 to 12.8 mm. This lead 
to an increase of the DSSSD rate of a factor | 
   | 
| 
  447  
 | 
Tue May 25 13:49:51 2021 | 
Oliver, Diego, Jan | General | No Beam | 2021 | No beam from 13:49:00 until  | 
   | 
| 
  552  
 | 
Sat May 29 23:05:52 2021 | 
Oliver, Diego | General | No Beam | 2021 | Due to a radioprotection issue in CaveA there 
is no beam. We wait for the radioprotection 
shift to arrive...
 | 
   | 
| 
  414  
 | 
Mon May 24 06:30:42 2021 | 
Ragan | DAQ | NTCAP | 2021 | NTCAP started for recording Schottky data
 
 
SC_2021-05-24_06-29-31
 | 
   | 
| 
  2  
 | 
Thu Jan 17 08:45:43 2019 | 
Jan | Detectors | Micron W1 DSSSD - technical information |   | Attached are the spec sheets and design drawings 
of the new DSSSDs from Micron.
 
Additionally, the 3D model made by Laszlo | 
 6x   | 
| 
  119  
 | 
Sat Mar 21 11:30:04 2020 | 
Laszlo | General | MWPC movement |   | now we try to move the capture detector (MWPC 
in the 1. dipol before our Si setup) inside 
the ring while the DAQ was ON
 | 
    | 
| 
  14  
 | 
Tue Jun 25 21:19:50 2019 | 
Laszlo | Simulations | MOCADI input parameters |   | initial BEAM input parameters for MOCADI are 
based on:
 
- https://web-docs.gsi.de/~weick/mocadi/download/esr-exl-test.in | 
     | 
| 
  128  
 | 
Sat Mar 21 13:37:53 2020 | 
Laszlo |   | MCP can monitor target |   | now with the MCP we can see clearly the effect 
of the target :) (scintillation?)
 
so we want to scan through the target thickness | 
   | 
| 
  452  
 | 
Tue May 25 22:03:22 2021 | 
Robert/Shahab | Runs | Lifetime measurement | 2021 | Run 0118
 
 
Gas jet target has been turned off for lifetime | 
   | 
| 
  185  
 | 
Sun Mar 22 12:50:00 2020 | 
Shahab | Runs | Life time of 10 MeV/u Tail of 118-Te-52+ |   | The life time of 10 MeV/u Tail of cycle 118-Te-52+ 
was analyzed using Schottky peak intensity. 
Schottky signal was taken from the parallel | 
     |