  216   Mon Mar 23 03:04:56 2020 ShahabRunsrun entry - run093 RUN 93 is with faulty SIS kicker module. Let's
see what we can get. waiting for SIS kicker
on-call duty (rufbereitschaft) to come.
  
  217   Mon Mar 23 03:07:11 2020 ShahabRunsSIS Kicker problem After calling ESR on-call duty (M. Steck)
he confirmed that the ESR is fine and suspected
the SIS kicker modules.
 IMG_20200323_021051.jpg 
  218   Mon Mar 23 03:38:01 2020 ShahabRunsrun entry - run093 RUN 93 is with faulty SIS kicker module. Let's
see what we can get. waiting for SIS kicker
on-call duty (rufbereitschaft) to come.
  
  219   Mon Mar 23 03:53:41 2020 ShahabRunsReduced intensity inspite of faulty kicker SIS Kicker is still faulty. but we managed
to reduce again the intensity to around 2e6
particles in ring to reduce scattering on
  
  220   Mon Mar 23 03:58:25 2020 ShahabGeneralKicker guy arrived Kicker Guy (U. Blell) arrived in order to
fix modules.
  
  221   Mon Mar 23 04:08:12 2020 ShahabRunsrun 93 stopped run 93 which was during faulty kicker was
stopped so that the kicker module can be
repaired.
  
  222   Mon Mar 23 05:55:24 2020 ShahabRunsKicker problem not solved yet no solution to kicker problem.    
  223   Mon Mar 23 05:59:01 2020 ShahabRunsSIS Kicker  SIS Kicker seems to be working properly. but
we have to see how regularly it will work.
  
  224   Mon Mar 23 06:20:06 2020 ShahabRunsPosition on scintillator corrected sitll no beam in ESR position on the scintillator was corrected
by the OPs to center, but beam is still not
in ESR.
 IMG_20200323_061337.jpg 
  225   Mon Mar 23 06:40:17 2020 ShahabRunsno beam in SIS nor in ESR manic Monday morning.   
  226   Mon Mar 23 06:49:46 2020 ShahabRunsESR kicker also has some problems     
  572   Tue Jun 8 15:06:17 2021 ShahabAnalysisBeam lifetime2021measured beam lifetime after the second deceleration
using parallel plate Schottky detector and
the RSA5103 spectrum analyser. Analysis code
 pgamma_lifetime.001.pngpgamma_lifetime.002.png 
  228   Mon Mar 23 08:04:07 2020 Shahab, Laszlo,YuryRunsrun entry - run0942020open file : run094

beam: 124Xe54+
 2020-03-23_08-13-00-443.png 
  229   Mon Mar 23 08:20:31 2020 Shahab, Laszlo,YuryRunsrun entry - run095 open file : run095

beam: 124Xe54+
 2020-03-23_08-31-45-715.png 
  570   Mon May 31 14:38:33 2021 SophiaCalibrationRunlist for X-ray detector calibrations after the experiment2021The by Jacobus Swartz created table in entry
335 extended by the calibration after the
experiment.
 Kopie_von_E127_Runlist-calibrations-4-3-1.xlsx 
  415   Mon May 24 11:12:38 2021 Sophia, MarioRunsRun 00902021DAQ node 2 was not started!

  
  416   Mon May 24 11:25:46 2021 Sophia, MarioRunsRun 00912021open file : e127b_run0091.lmd

beam: 118Te52+
  
  417   Mon May 24 12:29:20 2021 Sophia, MarioRunsRun 0092202120 stacks now

open file : e127b_run0092.lmd
  
  418   Mon May 24 13:14:59 2021 Sophia, MarioRunsRun 00932021No. of stacks: 5
length SC10: 2x 5.5s 
  
  419   Mon May 24 14:12:14 2021 Sophia, MarioRunsRun 00942021No. of stacks: 5
length SC10: 2x 5.5s 
bump ge01sq2f (sc10): -10 mm (before -20
  