ID Date Author Category Subject Yeardown Text Attachments
  249   Mon Mar 23 14:12:54 2020 RaganRunsE127 experiment stops close file : run104 (14:12:44)
E127 experiment finishes on a successful
note )) Congratulations to the entire team
  
  250   Mon Mar 23 14:23:01 2020 Pierre-MichelDAQBackup recoil files Recoil detector files backup to lxg1260:/data.local2/hillenbrand/Laszlo   
  251   Mon Mar 23 14:32:03 2020 JanAnalysisruns_100to104 NO-SCRAPER RESULTS Without scraper, we have very few (p,g) counts,
hard to get numbers quickly, maybe ~50.
 124Xe_Si_map.png124Xe_Si_projection.png124Xe_x-ray_35.png124Xe_x-ray_90.png124Xe_x-ray_145.png 
  253   Mon Mar 23 15:48:15 2020 LaszloCalibrationrun105 - Xray90 calib Am241, distance 167.5mm, wrong? Detector: 90
Source: Am241 
Distance: 167.5mm
  
  254   Mon Mar 23 16:17:58 2020 LaszloCalibrationrun106 - garbage! run106 was clicked by accident, please delete!   
  255   Mon Mar 23 16:21:33 2020 LaszloCalibrationrun107 - Xray90 calib Am241, distance 167.5mm Detector: 90
Source: Am241 
Distance: 167.5mm
  
  256   Mon Mar 23 17:32:42 2020 LaszloCalibrationrun108 - Xray90 calib Ba133, distance 167.5mm - high rate - deadtime too high! Detector: 90
Source: Ba133 - strong source
Distance: 167.5mm
  
  257   Mon Mar 23 17:40:33 2020 LaszloCalibrationrun109 - Xray90 calib Ba133, distance 167.5mm -low rate Detector: 90
Source: Ba133 - weak source
Distance: 167.5mm
  
  258   Mon Mar 23 18:15:55 2020 LaszloGeneralnoisy 90degree Xray det Uwe found out, that there was some common
ground effect between 90 and 145 degree detectors.
after moving the grounds, we could record
  
  259   Mon Mar 23 18:17:27 2020 LaszloCalibrationrun110 - Xray90 calib Ba133, distance 167.5mm -low rate - LESS NOISE Detector: 90
Source: Ba133 - weak source
Distance: 167.5mm
  
  260   Mon Mar 23 19:32:53 2020 LaszloCalibrationrun112 - Xray90 calib Am241, distance 200mm - LESS NOISE Detector: 90
Source: 241Am
Distance: 200mm
  
  261   Mon Mar 23 20:52:37 2020 LaszloCalibrationrun113 - Xray145 calib Am241, distance 305mm - LESS NOISE Detector: 145
Source: 241Am
Distance: 305mm
  
  262   Mon Mar 23 21:47:40 2020 LaszloCalibrationrun114 - Xray145 calib Ba133, distance 305mm - LESS NOISE Detector: 145
Source: 133Ba - strong source
Distance: 305mm
  
  263   Mon Mar 23 22:25:41 2020 LaszloCalibrationrun115 - Xray35 Ba133 d=334mm, Xray90 Lead source, d=167.5mm Simultaneous measurement of Xray35 and Xray90.
The dead-time is <3%
  
  264   Tue Mar 24 00:11:35 2020 LaszloCalibrationrun116 - Xray35 calib AM241, distance 334mm Detector: 35
Source: 241Am
Distance: 334mm
  
  265   Tue Mar 24 10:20:26 2020 LaszloCalibrationPictures of the xray calibration    IMG_20200324_101357.jpgIMG_20200324_101303.jpgIMG_20200324_101334.jpgIMG_20200324_100725.jpg 
  266   Tue Mar 24 10:59:18 2020 JanCalibrationSources - Specifications We used the following sources:

[B]Am241[/B] (OM666) [GSI - Uwe]
 Pb-210-1.pdf241Am_Uwe.pdf133Ba_low.pdf133Ba_hi.pdf 
  267   Wed Mar 25 14:26:22 2020 LaszloCalibrationrun111 - Xray90 calib Am241, distance 167.5mm - LESS NOISE Detector: 90
Source: 241Am
Distance: 167.5mm
  
  268   Wed Mar 25 15:06:09 2020 LaszloAnalysisquick summary of the run numbers    SP54120032515060.pdf 
  269   Thu Mar 26 12:05:22 2020 LaszloCalibrationmeasurement of collimators The measurements were taken by using a caliper
ruler, with precision of +/-0.05mm
 SP54120032612091.pdfSP54120032612090.pdf 