241
|
Mon Mar 23 12:30:39 2020 |
laszlo | Analysis | with and without scraper | | |
|
244
|
Mon Mar 23 13:26:59 2020 |
Jan | Analysis | runs_90to99 SCRAPER RESULTS | | With scraper, we have roughly 150-200 (p,g)
counts now.
|
|
251
|
Mon Mar 23 14:32:03 2020 |
Jan | Analysis | runs_100to104 NO-SCRAPER RESULTS | | Without scraper, we have very few (p,g) counts,
hard to get numbers quickly, maybe ~50.
|
|
268
|
Wed Mar 25 15:06:09 2020 |
Laszlo | Analysis | quick summary of the run numbers | | |
|
Draft
|
Tue Apr 21 22:25:00 2020 |
Jan | Analysis | | | |
|
285
|
Fri Nov 20 15:53:37 2020 |
Jan | Analysis | Test of 2nd DSSSD (gen2) | 2021 | Here is the analysis of the test runs with
the 2nd DSSD (gen2) using the quick_si_plots.c
script attached.
|
|
360
|
Fri May 21 01:17:37 2021 |
Laszlo | Analysis | simple analysis code | 2021 | //a simple code (template) for offline analysis
//made by Laszlo, serves as a simple demonstration
for enthusiastic shifters
|
|
445
|
Tue May 25 11:58:30 2021 |
Jan | Analysis | 118(p,g) counts until run0115 | 2021 | The two attached plots show the collected
Si data up to run0115.
|
|
469
|
Wed May 26 14:28:23 2021 |
Jan | Analysis | Xrays from 118Te & 124Xe | 2021 | Attached is a plot of the uncalibrated energy
spectra taken with the 90 degree xray detector
for 118Te (red) and 124Xe (blue).
|
|
523
|
Fri May 28 15:15:06 2021 |
Jan | Analysis | 118Te(p,g) counts runs 135 to 174 | 2021 | This is the summary of all Si data collected
at 6 MeV/u until run174 before the Alvarez
problem.
|
|
572
|
Tue Jun 8 15:06:17 2021 |
Shahab | Analysis | Beam lifetime | 2021 | measured beam lifetime after the second deceleration
using parallel plate Schottky detector and
the RSA5103 spectrum analyser. Analysis code |
|
41
|
Sun Mar 15 09:42:40 2020 |
Jan | Calibration | run030 - Xray90 calib Am241 | | measurement with old tennelec specAmps, do
not use for efficiency!
|
|
42
|
Sun Mar 15 13:08:38 2020 |
Jan | Calibration | run031 - Xray90 calib Ba133 hi-rate | | measurement with old tennelec specAmps, do
not use for efficiency!
|
|
43
|
Sun Mar 15 13:40:11 2020 |
Jan | Calibration | run032 - Xray90 calib Ba133 | | measurement with old tennelec specAmps, do
not use for efficiency!
|
|
44
|
Sun Mar 15 13:52:05 2020 |
Jan | Calibration | run033 - Xray145 calib Am241 | | measurement with old tennelec specAmps, do
not use for efficiency!
|
|
45
|
Sun Mar 15 14:41:34 2020 |
Jan | Calibration | run034 - Xray145 calib B133 high rate -SOURCE MOVED! | | measurement with old tennelec specAmps, do
not use for efficiency!
|
|
46
|
Sun Mar 15 15:08:44 2020 |
Jan | Calibration | run035 - Xray145 calib B133 high rate | | measurement with old tennelec specAmps, do
not use for efficiency!
|
|
48
|
Sun Mar 15 17:13:21 2020 |
Laszlo, Jan | Calibration | the x-ray gate issue | | We found a strange behaviour of our ADC gates
for the x-ray detectors.
The setting as shown in the foto below corresponds |
|
49
|
Sun Mar 15 17:14:08 2020 |
Laszlo | Calibration | run036 - Xray90 calib Am241, distance 200! | | Detector: 90
Source: Am241
Distance: 200mm
|
|
50
|
Sun Mar 15 17:33:17 2020 |
Laszlo | Calibration | run037 - Xray90 calib Am241 | | Detector: 90
Source: Am241
Distance: 167.5mm
|
|