HOME
ESR
EXPERIMENTS
LABS etc
E121
E127
E132
E125
E143
laser_cooling_2021
E142
Ê128
E146
E0052
E0018
proton-capture on 118Te, Page 2 of 29
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Category --
Analysis
Calibration
DAQ
General
Collaboration
Runs
Detectors
Simulations
Accelerator
572 Entries
Goto page
Previous
1
, 2,
3
...
27
,
28
,
29
Next
ID
Date
Author
Category
Subject
Year
Text
32
Tue Feb 11 13:20:01 2020
Jan
Detectors
BaF2 - HV settings
with these HV values the 6 channels are roughly
gain matched, such that the 7.83 MeV Po-decay
is around channel 5000.
88
Fri Mar 20 22:26:42 2020
Jan
Detectors
BaF2 deactivated
BaF2 detectors are deactivated nor for the
following runs.
3
Wed Feb 6 10:04:23 2019
Laszlo Varga
Simulations
Background subtraction for 124Xe, 109In, 73As made by MOCADI
General remarks to the MOCADI simulations:
scraper size vertically > (p,g) spot at the
scraping position --> (p,g) can be separated
250
Mon Mar 23 14:23:01 2020
Pierre-Michel
DAQ
Backup recoil files
Recoil detector files backup to lxg1260:/data.local2/hillenbrand/Laszlo
449
Tue May 25 17:12:59 2021
Robert/Shahab
Accelerator
Beam
2021
Beam is back; It is now being optimized
353
Wed May 19 19:47:14 2021
Yuri
General
Beam Halflife at 30 AMeV
2021
572
Tue Jun 8 15:06:17 2021
Shahab
Analysis
Beam lifetime
2021
measured beam lifetime after the second deceleration
using parallel plate Schottky detector and
the RSA5103 spectrum analyser. Analysis code
350
Tue May 18 21:08:16 2021
ESR team
General
Beam stacking
2021
Beam stacking. 3 pulses, stochastically cooled
and stacked on an inner orbit
Draft
Fri Jun 28 14:06:28 2019
Jan
General
CAD of (p,g) setup
316
Thu May 6 11:03:46 2021
Jan Glorius
DAQ
Cabling Documentation
2021
346
Sun May 16 13:31:49 2021
Laszlo
DAQ
Cabling Documentation
2021
Si HV and current was switched in the last
documentation.
471
Wed May 26 15:30:03 2021
Ragan, Thanassis
General
Changing the beam energy
2021
The ESR team is changing the beam energy to
6 MeV/u.
475
Wed May 26 19:08:17 2021
Ragan, Thanassis
General
Cooler down
2021
We stopped data taking as the electron cooler
is down.
273
Wed Apr 8 20:06:10 2020
Laszlo
Calibration
Counts in the K-REC peaks
3 datasets were investigated:
-124Xe with Scraper (2. Xray calibration
parameters needed)
39
Wed Mar 11 09:08:21 2020
Jan
DAQ
DAQ & controls - OVERVIEW
For all DAQ & slow control buissines the user
[COLOR=red][SIZE=3]litv-exp[/SIZE][/COLOR]
71
Fri Mar 20 04:29:45 2020
Jan
DAQ
DAQ settings for the first night
12
Fri Jun 7 15:57:41 2019
Jan
DAQ
DAQ with & without MDPP-16
The DAQ located in
../esrdaq_2018/r4l-58/
26
Wed Oct 23 15:35:29 2019
Jan
DAQ
DAQ with & without MDPP-16
the DAQ located in
../esrdaq_2018/r4l-58_dev/
386
Sat May 22 14:53:34 2021
Beatriz et al.
General
DSSD Movement
2021
DSSSD moved to the most in position in order
to try to scrape the beam with the scraper.
286
Tue Nov 24 15:35:49 2020
Jan
Calibration
DSSD X/Y channel mapping
2021
During the detector test [URL=https://elog.gsi.de/esr/E127/284]test
measurements[/URL] with alpha source the
allocation of the 16 X- and 16 Y-channels
Goto page
Previous
1
, 2,
3
...
27
,
28
,
29
Next
ELOG V3.1.5-fc6679b