  32   Tue Feb 11 13:20:01 2020 JanDetectorsBaF2 - HV settings with these HV values the 6 channels are roughly
gain matched, such that the 7.83 MeV Po-decay
is around channel 5000.
 BaF2_HV_settings.pngbaf_bg_ch1.png 
  88   Fri Mar 20 22:26:42 2020 JanDetectorsBaF2 deactivated BaF2 detectors are deactivated nor for the
following runs.
  
  3   Wed Feb 6 10:04:23 2019 Laszlo VargaSimulationsBackground subtraction for 124Xe, 109In, 73As made by MOCADI General remarks to the MOCADI simulations:


scraper size vertically > (p,g) spot at the
scraping position --> (p,g) can be separated
 template.pdf 
  250   Mon Mar 23 14:23:01 2020 Pierre-MichelDAQBackup recoil files Recoil detector files backup to lxg1260:/data.local2/hillenbrand/Laszlo   
  449   Tue May 25 17:12:59 2021 Robert/ShahabAcceleratorBeam2021Beam is back; It is now being optimized   
  353   Wed May 19 19:47:14 2021 YuriGeneralBeam Halflife at 30 AMeV2021   2021-05-19_17-35-00_tcl1032_lassie-monitor.png 
  572   Tue Jun 8 15:06:17 2021 ShahabAnalysisBeam lifetime2021measured beam lifetime after the second deceleration
using parallel plate Schottky detector and
the RSA5103 spectrum analyser. Analysis code
 pgamma_lifetime.001.pngpgamma_lifetime.002.png 
  350   Tue May 18 21:08:16 2021 ESR teamGeneralBeam stacking2021Beam stacking. 3 pulses, stochastically cooled
and stacked on an inner orbit
 5B6943AF-DF56-4B0F-A77E-1E3C65B3B0C0.jpegB590F232-450A-4ACF-BBA4-DB31B7B35FDA.jpeg 
  Draft   Fri Jun 28 14:06:28 2019 JanGeneralCAD of (p,g) setup     
  316   Thu May 6 11:03:46 2021 Jan GloriusDAQCabling Documentation2021   e127b_cabling_docu_06_05_2021_.pdfe127b_2021_cabling_documentation.xlsx 
  346   Sun May 16 13:31:49 2021 LaszloDAQCabling Documentation2021Si HV and current was switched in the last
documentation.
 e127b_2021_cabling_documentation.xlsx 
  471   Wed May 26 15:30:03 2021 Ragan, ThanassisGeneralChanging the beam energy 2021The ESR team is changing the beam energy to
6 MeV/u.
  
  475   Wed May 26 19:08:17 2021 Ragan, ThanassisGeneralCooler down2021We stopped data taking as the electron cooler
is down.
  
  273   Wed Apr 8 20:06:10 2020 LaszloCalibrationCounts in the K-REC peaks 3 datasets were investigated:
-124Xe with Scraper    (2. Xray calibration
parameters needed)
 124Xe_wScraper_full_spectra_labels_thick.png124Xe_wScraper_90_backgnd.pngKREC-pics.zip 
  39   Wed Mar 11 09:08:21 2020 JanDAQDAQ & controls - OVERVIEW For all DAQ & slow control buissines the user

[COLOR=red][SIZE=3]litv-exp[/SIZE][/COLOR]
  
  71   Fri Mar 20 04:29:45 2020 JanDAQDAQ settings for the first night    e127.trlomain.cfgr3bfuser.cfgsetting.1584673412 
  12   Fri Jun 7 15:57:41 2019 JanDAQDAQ with & without MDPP-16 The DAQ located in 

../esrdaq_2018/r4l-58/ 
  
  26   Wed Oct 23 15:35:29 2019 JanDAQDAQ with & without MDPP-16 the DAQ located in
../esrdaq_2018/r4l-58_dev/
  
  386   Sat May 22 14:53:34 2021 Beatriz et al.GeneralDSSD Movement2021DSSSD moved to the most in position in order
to try to scrape the beam with the scraper.
  
  286   Tue Nov 24 15:35:49 2020 JanCalibrationDSSD X/Y channel mapping2021During the detector test [URL=https://elog.gsi.de/esr/E127/284]test
measurements[/URL] with alpha source the
allocation of the 16 X- and 16 Y-channels
  
ELOG V3.1.5-fc6679b