Fri Aug 9 13:14:09 2019 |
Laszlo | | pn channel simulations for 111Sn(p,g)112Sb experiment | | The p,n channel opening for the 111Sn+p reaction
is at 5.8895 MeV/u beam energy. Therefore,
when choosing as 6MeV/u, 7MeV/u, 8MeV/u beam |
|
118
|
Sat Mar 21 11:25:47 2020 |
Laszlo | | possible misalignement between target and fragment beam | | after 9hours of measurement we see only 19
counts on our targetON silicon detector histo.
this low count rate can indicate two scenarios:
|
|
128
|
Sat Mar 21 13:37:53 2020 |
Laszlo | | MCP can monitor target | | now with the MCP we can see clearly the effect
of the target :) (scintillation?)
so we want to scan through the target thickness |
|
199
|
Sun Mar 22 17:47:27 2020 |
Laszlo | | Si, Xrays target density spectra during 118Te afternoon measurement | | We got 30 counts out of this afternoon 118Te
run on our Si TargetON histo.
That 1 count at bin (6,10) I dont understand.
|
|
201
|
Sun Mar 22 18:35:43 2020 |
Laszlo | | target dropped aagain | | there was a drop again from 8.6e13 to 7e13
in the target density |
|
203
|
Sun Mar 22 19:15:03 2020 |
Laszlo | | Si moved out of the ring, high voltage is switched off | | |
|
204
|
Sun Mar 22 19:49:12 2020 |
Michael, Laszlo, Yuri | | Yuri is still tuning FRS | | We filled the Xray detectors.
Yuri is sill tuning FRS for primary beam. |
|
361
|
Fri May 21 10:00:51 2021 |
Jan | Accelerator | target bump | 2021 | The target overlap was optimized on xray and
si rates.
The setting now is -10mm in SC9 |
|
413
|
Mon May 24 05:20:36 2021 |
Helmut, Yuri, Faraz, Sergey | Accelerator | FRS setup | 2021 | Logbook from start of FRS until 118Te injection |
14x |
438
|
Tue May 25 07:51:48 2021 |
Jan | Accelerator | ESR stacking cycle length | 2021 | The full cycle length of ESR with 30 stacks
is about 7:45 minutes, out of which 15.5
sec are with target switched ON.
|
|
448
|
Tue May 25 15:56:48 2021 |
Robert/Shahab | Accelerator | Trafo | 2021 | Trafo was set to 0 |
|
449
|
Tue May 25 17:12:59 2021 |
Robert/Shahab | Accelerator | Beam | 2021 | Beam is back; It is now being optimized |
|
450
|
Tue May 25 18:46:04 2021 |
Robert/Shahab | Accelerator | Quadrupoles down | 2021 | All quadrupoles went off, waiting for the
on-call service |
|
496
|
Thu May 27 13:26:35 2021 |
Jan | Accelerator | FRS degrader failure | 2021 | Maybe, our degrader in FRS was removed by
hand at (~13:40 26/05/21)
It is put back now (~13:10 27/05/21)
|
|
497
|
Thu May 27 13:48:18 2021 |
Helmut Weick | Accelerator | FRS wrong status display for one day | 2021 | By checking the log files we realized that
from yesterday 26.05. 13:44 - today 13:05
the FRS degrader was shown as out.
|
|
18
|
Tue Jul 23 10:46:29 2019 |
Laszlo | Analysis | 124Xe pg peak fit using mixed cascade simulation | | This entry is the continuation of the cascade
effects on the pg peak shape entry:
|
7x |
22
|
Wed Sep 25 13:03:46 2019 |
Laszlo | Analysis | simulations on 118Te+p | | I have made some simulations at 8AMeV, 7AMeV
and 4AMeV energies for the main 118Te + p
reaction channels. For the
|
11x |
83
|
Fri Mar 20 13:21:33 2020 |
Jan, Laszlo | Analysis | 124Xe data of first night | | The unpacked data of all runs from the first
night (46-50) is located at
litv-exp@lxg0188:/data.local2/E127_lmd/124Xe_1st_night.root
|
|
153
|
Sat Mar 21 23:19:14 2020 |
Jan | Analysis | 118Te52+ on H2-target - Xray spectrum 90 degree | | The attached spectrum is for the 90 degree
X-ray detector taken for about 3 hours with
118Te52+.
|
|
159
|
Sun Mar 22 01:36:14 2020 |
Pierre-Michel | Analysis | Target overlap | | Here are the data file for the rates of the
recoil detector for different values of the
target bump. The average rate over background |
10x |