205
|
Mon Apr 11 07:54:37 2022 |
Danyal, Alexandre, Kristian, Sebastian | Accelerator | Jump in E-cooler voltage | We saw a jump in the E-cooler voltage at about
7:50.
jump from 209619 to 209610 V
|
|
93
|
Tue Apr 5 09:39:01 2022 |
Danyal & Yuri | Accelerator | Strahl ist wieder im ESR - Schlitz war reingefahren | Der Strahl ist wieder im ESR!
Angeblich war einen Schlitz, oder sogar 2,
reingefahren worden.
|
|
94
|
Tue Apr 5 09:45:47 2022 |
Danyal & Yuri | Accelerator | beam is back in the ESR - a slit was moved in | And now also in English :)
The ion beam is back in the ESR!
|
|
165
|
Fri Apr 8 14:46:02 2022 |
Danyal & Sebastian & Volker & Ken | Detectors | high dark countrate Cu PMT solved | The problem - "discovered" by Volker and Ken
- of the high dark countrate of the Cu PMT
has been solved.
|
|
140
|
Thu Apr 7 15:18:25 2022 |
Danyal & Sebastian | DAQ | DAQ channels | We checked again the cables for both DAQs
(on Carsten's kind request)
|
|
106
|
Wed Apr 6 08:31:54 2022 |
Danyal & Regina | General | ESR had some errors | Regina noticed that the ESR was "red"
This means that there are some errors.
|
|
113
|
Wed Apr 6 18:51:33 2022 |
Danyal & Carsten | Accelerator | target bump | This afternoon, we found out that Sergey has
also implemented a "target bump".
Although we do not use a target, this bump |
|
105
|
Wed Apr 6 08:06:02 2022 |
Danyal | DAQ | stopped NTCAP data acquisition | I stopped the NTCAP data acquisition at 8
AM.
|
|
107
|
Wed Apr 6 09:30:53 2022 |
Danyal | Accelerator | ESR is blue again - errors are fixed | The ESR is "blue" again.
The errors (scu related) have been fixed. |
|
139
|
Thu Apr 7 14:13:27 2022 |
Danyal | Detectors | new PMT south | I have replaced the PMT south (looks at the
gas target).
in the hope that this will produce less dark |
|
206
|
Mon Apr 11 10:17:01 2022 |
Danyal | Accelerator | Interlock - reset | 10:17
Wie heutemorgen in der Sitzung (morning briefing)
vereinbart,
|
|
159
|
Fri Apr 8 11:02:04 2022 |
DW, YL, RSS, SL | | Change h=2 to h=1 | After changing to h=1
The frequency manipulation #5: f=242.021487MHz
(124th harmonic) [no bunching]
|
|
201
|
Sun Apr 10 15:29:37 2022 |
Carsten,Sarper | Accelerator | Ecooler failed | Ecooler failed @15:23 Carsten is fixing it
Fixed @16:00 |
|
185
|
Sat Apr 9 15:47:21 2022 |
Carsten, Rodolfo, Sarper, Patrick | Runs | Afternoon and night shift runs | After the morning shift, we got new increment
(nm) for the laser scanning. We are now scanning
2 nm of wavelength range in 5 big steps (5 |
|
223
|
Wed Apr 13 14:29:04 2022 |
Carsten, Rodolfo, Sarper, David, Pierre-Michel, Max, Sebastian | Runs | Afternoon - morning shift runs 13.+14.04. | Changed the wavelength scan range from [B]321.62
- 321.10 nm[/B] to [B][B]321.12 - 320.60[/B]
nm[/B] after one scan.
|
|
200
|
Sun Apr 10 15:16:19 2022 |
Carsten, Rodolfo, Sarper | Runs | Runs afternoon shifts 10.04 | These are the measurement runs of the afternoon
shift (10.04.).
|
|
230
|
Thu Apr 14 17:47:55 2022 |
Carsten, Rodolfo, Konstantin, Sarper | Runs | Afternoon shift runs 14.04 changing the wavelength scan range | The new scan range is changed from [B]321.12
- 320.60 nm to 320.62 - 320.10 nm[/B]
|
|
21
|
Fri Mar 18 16:51:27 2022 |
Carsten | DAQ | Main DAQ /MBS error | MBS error "TDC data ready wait" solved. Common
stop trigger (20 kHz) was missing. (according
to Sebastian) |
|
29
|
Wed Mar 23 15:38:15 2022 |
Carsten | General | Not all lights in the ESR can be switched off | Three of the lights in the ESR cannot be switched
off. It seems that these lights are now "emergency
lights" (with battery?). We will need to |
|
34
|
Thu Mar 24 17:10:33 2022 |
Carsten | DAQ | DAQ / MBS VUPROM TDC buffer errors | VUPROM TDC buffer errors potentially due to
long TDC common Stop gate (>1ms from div
200).
|
|