HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038
  Nuclear hyperfine mixing in 229Th89+, Page 12 of 12  Not logged in ELOG logo
ID Date Author Categorydown Subject
  Draft   Sat Apr 2 01:02:39 2022 Carsten Test measurements with two DAQs
We do two measurements:

One measurement using the 
  67   Sat Apr 2 17:47:16 2022 Ken Ueberholz  Telefon, Gästehaus
My guesthouse phone number: 06159-71-2957
  71   Sat Apr 2 22:43:36 2022 Carsten Ring set-up for 229/89+, scraped and bunched, Iel=500mA at injection and 100mA during measurment
The ring SIS/ESR were set up for 229/89+. Pölease note that this not only 1e- Th but ponteially also the isobars of Ac (0e-1)/Pa(2e-, strongest) and U(3e-).
SIS eenrgy plus 3.5 MeV/u w.r.t. to the 238U92+ settings. We nearly don't see any of the primary beam in the ring
Cooling energy is 208998 KeV (read from the ESR multimeter).
The positioning of the scrapers is automatized but needs to be checked again tomorrow.
In order to allow for a longer measurment time, the electron curent is 500mA only during injection but is decreased to 100mA during measurement (=> longer beam lifetime).

 
 
  72   Sat Apr 2 23:16:55 2022 Carsten Cu mirror and CsI moved in and out of the ring
Ken tested the Cu-mirror and CsI disk Detector. They move without a problem and don't scrape the ion beam.
  73   Sun Apr 3 00:41:45 2022 Ken Ueberholz  Xuv-Detektor Signale
The Xuv-detector cabel channels seem to be 
wrongly labeled in the Messhütte (see 
picture) and are propably also wrongly 
connected. Need to be relabeled and reconnected either in the 
messhütte or in the laserlab. I will look for the best 
solution tomorrow morning. 
  81   Sun Apr 3 15:34:34 2022 Ken Ueberholz  Xuv-Detektor CFD-treshhold
I co controlled all detector signals and 
adjusted the threshold to be just above 
the noise. I will double check this when 
the detector can be moved in and we have a 
beam. 
  126   Thu Apr 7 04:48:58 2022   ToDo's for 07.04.
Some ToDo's for the next shift:
- Work on  Laser stabilisation 2nd stage in the ESR
- Mesytec power supply of the xuv-detector crashed and needs to be restarted in the ESR. Simply turning it the crate off and on again)!!
- Fix wavemeter fluctuates
- Compare MBS event size of DAQ 1 ("by laser group") and DAQ 2 ("by Carsten"), DAQ 1 data size was ~2 times larger than DAQ 2 data size.
- Use lmd-files measured last night to test Go4-Analysis.
- Practice measurement procedure with beam, see Message ID: 124.
  144   Thu Apr 7 22:18:06 2022 Night shift 7.4-8.4 Next scans
DAQ1: lxg1927:/data.local2/BeamTimeTh22/
DAQ2: lxg0155:/data.local2/E142/
LMD file name DAQ1:229Thor
LMD file name DAQ2:229Th

Shottky and NTCAP started at 23:53, center freq. 242.2M, 10MIQs, -30dBm
Shottky marker pos: 243.973MHz

TimeSIS-intensitycooler-HVLMD-DAQ1LMD-DAQ2scan range(nm)step width(nm)dwell time(s)comments
00:201.4e92096170065-00677810323.2-321.20.014buggy DAQ? see Elog, file 0068 empty
01:271.6e92096060069-00707811323.2-321.20.014buggy DAQ? see Elog, file 0071 empty
02:151.6e92096110072-00737812323.2-321.20.014buggy DAQ? see Elog, file 0074-0075, 7813-7814 empty
03:001.1e9?0076-00777815323.2-321.20.014buggy DAQ? see Elog and below, file 0078, 7816 empty




We were searching for a difference of a factor of twoin both DAQs. It turns out that the default value for the MBSstream server task is scale=2. In the main task this value is explicately set to scale=1. we will now (starting with filenumber: 0078) restart the 2nd DAQ with set stream_serv scale=1.

Also TDC is disabled.
From file number 0076 in DAQ2 : ADC thresholds:
unsigned short caen_V785AH_threshold_mod0 [32] =
{0x0100 , 0x0005 , 0x0004 , 0x0003 , 0x0004 , 0x0003 , 0x0005 , 0x0003 ,
0x0005 , 0x0004 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 ,
0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 ,
0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 };


Before the next scan, we realized, that the laser destabilized. For the rest of the shift we tried to get laser back online (see ID:149).
  156   Fri Apr 8 09:33:52 2022 Dayshift 1 8.4.2022 Reference Measurements
DAQ1: lxg1297:/data.local2/BeamTimeTh22/
DAQ2: lxg0155:/data.local2/E142/
LMD file name DAQ1:229Thor
LMD file name DAQ2:229Th

center freq. 242.2M, 10MIQs, -30dBm
Shottky marker pos: 243.973MHz

TimeSIS-intensitycooler-HVLMD-DAQ1LMD-DAQ2scan range(nm)step width(nm)dwell time(s)comments
09:30??20961400797817323.2-321.20.0142 loops
10:152.3e920961100817820321.0-320.00.018just 1 loop, aborted 2nd loop and started from 320.5-320.4 in 0.005 steps and 10s dwell time (300), started again from 320.5-320.4 in 0.005 steps and 10s dwell time (300)


We crosschecked the last measurements from the nightshift for reference measurements.
Now the ESR group start switching to 1 bunch.
  159   Fri Apr 8 11:02:04 2022 DW, YL, RSS, SL Change h=2 to h=1
After changing to h=1
The frequency manipulation #5: f=242.021487MHz (124th harmonic) [no bunching]
Manipulation #7: f=242.021812 MHz [with bunching]
  168   Fri Apr 8 15:45:24 2022 YL Spectrum manipulation 5
See attached
  177   Sat Apr 9 04:01:35 2022 Carsten 2nd DAQ
Switched the CAEN TDC back on and changed the threshoolds for the ADC to:

unsigned short caen_V785AH_threshold_mod0 [32] =
{0x0100 , 0x0004 , 0x0003 , 0x0002 , 0x0003 , 0x0002 , 0x0004 , 0x0002 ,
0x0004 , 0x0003 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 ,
0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 ,
0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 };
  189   Sat Apr 9 19:50:40 2022 Carsten New thresholds for ADC of DAQ2 (starting with file0117)
unsigned short caen_V785AH_threshold_mod0 [32] = 
                {0x0100 , 0x0004 , 0x0003 , 0x0004 , 0x0005 , 0x0004 , 0x0006 , 0x0005 ,
                 0x0006 , 0x0005 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 ,
                 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 ,
                 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 };
ELOG V3.1.5-fc6679b