Nuclear hyperfine mixing in 229Th89+, Page 3 of 12
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Category --
Analysis
Calibration
DAQ
Laser
General
Runs
Detectors
Accelerator
233 Entries
Goto page
Previous
1
,
2
, 3,
4
...
10
,
11
,
12
Next
All
ID
Date
Author
Category
Subject
Text
41
Thu Mar 31 13:28:17 2022
Jan Glorius
DAQ
DAQ-2 cabling docu
newest version V2 - valid since Mo 04.April
2022
42
Thu Mar 31 15:53:50 2022
Konstantin
Detectors
Control software for XUV and copper mirror detector
> Attached you find a manual for the software
used to control the movement of the XUV detector
and the copper mirror detector.
43
Thu Mar 31 17:56:32 2022
Konstantin
DAQ
Photodiode test signal
We used a signal generator to provide a 4MHz
dummy-RF signal. This was divided by a factor
of 2 for laser-"bunch" synchronization and
44
Thu Mar 31 20:07:47 2022
Shahab
DAQ
Schottky Display in AP Messhütte (or anywhere else)
[B]UPDATE: 16.05.2022[/B]
[I]Please use ATPPC029 instead of ATPPC019
45
Thu Mar 31 22:19:14 2022
Kristian
DAQ
How To Start MBS
(MBS server should be running at the LXG1297
machine. If not you will get an error message.
Then start the server - last command in console)
46
Thu Mar 31 22:41:35 2022
Kristian
Calibration
HV divider
We noticed a difference in the electron cooler
high voltage:
47
Fri Apr 1 00:27:27 2022
Carsten
Settings Particle Detectors /Tests with primary beam
All the beam settings will be given in a separate
post.
49
Fri Apr 1 01:57:12 2022
Kristian
DAQ
Timing
with bunched primary beam (bunching frequency
1.94070 MHz) we have strong PMT (mid) and
particle detector signal. Time between both
50
Fri Apr 1 02:29:40 2022
Carsten
ESR Cooler crashed
ESR cooler crashed. We could not restart the
cooler. Since we had several other problems,
we stop now.
51
Fri Apr 1 11:00:41 2022
Rui-Jiu Chen
DAQ
Start NTCAP
Start taking data with NTCAP.
Carrier Frequency: 245MHz
IQ rate:5 MSamples/s
52
Fri Apr 1 11:19:57 2022
Rui-Jiu Chen
DAQ
S.M.A.R.T check on NTCAP
S.M.A.R.T. check has been done on NTCAP on
March 28th. All 12 hard disk drivers are
normal.
53
Fri Apr 1 15:27:00 2022
Rodolfo
Detectors
Nitrogen for UV-PMTs
There was a question concerning the nitrogen
we use to rinse the "Solar Blind PMTs".
54
Fri Apr 1 15:52:23 2022
Rodolfo
Detectors
UV PMT South
The "Solar Blind PMT" labeled as "PMT South"
has been installed by Simon and Max in the
gas target chamber on a CaF Viewport. The
55
Fri Apr 1 16:46:33 2022
Carsten
Detectors
All pressuzied air drives are tested now and are working properly
All pressuzied air drives are tested now and
are working properly
56
Fri Apr 1 18:19:58 2022
Kristian
Calibration
HV divider
We checked the strange behavior of the HV
dividers again. The Ohmlabs and the PTB divider
are in good agreement at 120 kV and 150 kV.
57
Fri Apr 1 18:30:38 2022
Carsten
Detectors
Positions / Voltages threshlds for particle detectors
[B]DC beam 238U92+ (205kV, e-beam)[/B]
We used the detector NA_SZ to determine the
central primary-beam (238U92+) position by
58
Fri Apr 1 22:01:14 2022
Konstantin
Detectors
PMT operating voltages
> During the testing of the PMTs the following
operating voltages were applied:
>
59
Fri Apr 1 23:12:37 2022
Patrick
Detectors
Scraper positions "only primary beam"
Scraper positions where there is only primary
beam for detector tests. Use only one outer
60
Fri Apr 1 23:47:45 2022
Carsten
Detectors
PMT thresholds / PMT north does not allow voltage abow ~ -1kV
Checked thresholds of PMT with beam and without
beam.
Draft
Sat Apr 2 01:02:39 2022
Carsten
Test measurements with two DAQs
We do two measurements:
One measurement using the