HOME
ESR
EXPERIMENTS
LABS etc
E121
E127
E132
E125
E143
laser_cooling_2021
E142
Ê128
E146
E0052
E0018
E0028
E0038
Nuclear hyperfine mixing in 229Th89+, Page 7 of 12
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Category --
Analysis
Calibration
DAQ
Laser
General
Runs
Detectors
Accelerator
233 Entries
Goto page
Previous
1
,
2
,
3
...
6
, 7,
8
...
10
,
11
,
12
Next
All
ID
Date
Author
Category
Subject
Text
34
Thu Mar 24 17:10:33 2022
Carsten
DAQ
DAQ / MBS VUPROM TDC buffer errors
VUPROM TDC buffer errors potentially due to
long TDC common Stop gate (>1ms from div
200).
41
Thu Mar 31 13:28:17 2022
Jan Glorius
DAQ
DAQ-2 cabling docu
newest version V2 - valid since Mo 04.April
2022
43
Thu Mar 31 17:56:32 2022
Konstantin
DAQ
Photodiode test signal
We used a signal generator to provide a 4MHz
dummy-RF signal. This was divided by a factor
of 2 for laser-"bunch" synchronization and
44
Thu Mar 31 20:07:47 2022
Shahab
DAQ
Schottky Display in AP Messhütte (or anywhere else)
[B]UPDATE: 16.05.2022[/B]
[I]Please use ATPPC029 instead of ATPPC019
45
Thu Mar 31 22:19:14 2022
Kristian
DAQ
How To Start MBS
(MBS server should be running at the LXG1297
machine. If not you will get an error message.
Then start the server - last command in console)
49
Fri Apr 1 01:57:12 2022
Kristian
DAQ
Timing
with bunched primary beam (bunching frequency
1.94070 MHz) we have strong PMT (mid) and
particle detector signal. Time between both
51
Fri Apr 1 11:00:41 2022
Rui-Jiu Chen
DAQ
Start NTCAP
Start taking data with NTCAP.
Carrier Frequency: 245MHz
IQ rate:5 MSamples/s
52
Fri Apr 1 11:19:57 2022
Rui-Jiu Chen
DAQ
S.M.A.R.T check on NTCAP
S.M.A.R.T. check has been done on NTCAP on
March 28th. All 12 hard disk drivers are
normal.
79
Sun Apr 3 12:35:17 2022
Max
DAQ
Go 4 manual
How to start go4?:
- go to console
85
Mon Apr 4 00:19:16 2022
Ken Ueberholz
DAQ
FirstTests
New measurement:
Start: About 00:12
Stop: About 00:43
87
Mon Apr 4 15:27:31 2022
Sebastian
DAQ
PMT over wavelength histogram
Kristian and I tried to create a "PMT over
wavelength" histogram under step2Anl/LabView.
Unfortunately, the code ist still in progress
88
Mon Apr 4 15:32:38 2022
Kristiand & Sebastian
DAQ
Go4 Backup Code
Due to some code changes (PMT over wavelength
historgram) Kristian and I backuped a working
Go4 code in the current go4 folder on the
89
Mon Apr 4 16:26:04 2022
Carsten
DAQ
Backup Harddisk /External Disk
Since we cannot write on lustre, as a temproal
solution two RAID 1 (mirror) USB hard disks
with cpacity 6 TB each are installed.
90
Mon Apr 4 17:26:48 2022
Jan Glorius
DAQ
MSCF shaper settings
attached are the current shaper settings.
list of currently connected channels:
91
Mon Apr 4 19:05:57 2022
Carsten
DAQ
Cooler Frequency Signals Ion current not connected until now
Up to now the signals for
Ion Current
Cooler elctron current
92
Tue Apr 5 08:00:50 2022
Kristian & Sebastian
DAQ
MBS Channellist (so far)
MBS Channellist (time 5.4.2022)
0 Anode
95
Tue Apr 5 11:14:52 2022
Sebastian, Kristian, Pierre-Michel
DAQ
PMT over wavelength histogram v2
Today we finalized the PMT over wavelength
histogram in:
96
Tue Apr 5 12:17:12 2022
Ragan, Rui-Jiu
DAQ
Instructions to start and stop NTCAP
Attached are the instructions to start and
stop data taking using the NTCAP.
98
Tue Apr 5 13:28:06 2022
Kristian
DAQ
Spikes in PMT signal
Occasionally, we noticed a spike in the PMT
signal. No ions in the ring and at PMT Cu
was not even supplied with HV. Has to be
99
Tue Apr 5 14:51:51 2022
Kristian
DAQ
dark counts
We shielded the PMTs, i.e., the N2 tube, which
improved the Cu PMT background rate.
Goto page
Previous
1
,
2
,
3
...
6
, 7,
8
...
10
,
11
,
12
Next
All