| ID | Date | Author | Category | Subject | Text |  | 
| 117 | Wed Apr  6 22:29:55 2022 | Patrick | Accelerator | ECooler voltages | ECooler voltages: 
 [B]06.04:[/B]
 |  | 
| 116 | Wed Apr  6 21:03:25 2022 | Ken Ueberholz | Detectors | Xuv-Detektor, further information | Some further information regarding the xuv-detector and its components.
 |   | 
| 115 | Wed Apr  6 19:39:08 2022 | Ken Ueberholz | Detectors | LED installed | The UV-LED of Münster was connected over channel 8 to the Messhütte. 6V are
 supplied by the power supply (picture 2).
 |    | 
| 113 | Wed Apr  6 18:51:33 2022 | Danyal & Carsten | Accelerator | target bump | This afternoon, we found out that Sergey has also implemented a "target bump".
 Although we do not use a target, this bump
 |  | 
| 112 | Wed Apr  6 16:01:07 2022 | BL | Accelerator | ESR settings before adjusting laser: 2022-04-06_14-37-30_ESR_EXP22_02_238U92_Brandau_30March22.C1.txt | # Version: 1.2 # Comment: ParamModi Export at 2022-04-06T14:37:35.957978+02:00[Europe/Berlin]
 # Context: ESR_EXP22_02_238U92_Brandau_30March22.C1
 |  | 
| 111 | Wed Apr  6 15:19:29 2022 | Svea, Shahab | Accelerator | 5s delay implemented before injection | Operators have informed us that for better stability and operation (and cooperation
 with HHT), and after discussing with Sergey,
 |  | 
| 110 | Wed Apr  6 14:52:29 2022 | Rodolfo | Runs | Scraping the ion beam | We are T-scraping the ion beam. |  | 
| 108 | Wed Apr  6 13:32:57 2022 | Max, Sebastian | DAQ | LabView Cobra Channel List | channel 0: linux time (epoch time) channel 1: ms timer
 channel 2: E-Cooler Voltage(Ohmlabs)
 |  | 
| 107 | Wed Apr  6 09:30:53 2022 | Danyal | Accelerator | ESR is blue again - errors are fixed | The ESR is "blue" again. 
 The errors (scu related) have been fixed.
 |  | 
| 106 | Wed Apr  6 08:31:54 2022 | Danyal & Regina | General | ESR had some errors | Regina noticed that the ESR was "red" 
 This means that there are some errors.
 |  | 
| 105 | Wed Apr  6 08:06:02 2022 | Danyal | DAQ | stopped NTCAP data acquisition | I stopped the NTCAP data acquisition at 8 AM.
 
 |  | 
| 104 | Tue Apr  5 23:55:11 2022 | Carsten | Runs | Long time measurment with NTCAP | Settings: Center: 2242.5MHz
 RefLevel: -25dB
 |  | 
| 103 | Tue Apr  5 23:07:34 2022 | Carsten | Accelerator | 229Th89+ identification after re-tuning of the ESR | The ESR was retuned this aftenoon since the it was unclear if we still sit the 229Th89+
 line.
 |  | 
| 102 | Tue Apr  5 20:58:53 2022 | Wilfried | Laser | Trigger for Laser | Electronic for the timing of the laser puls optimized. The problem with the broad photodiode
 histograms is solved.
 |    | 
| 101 | Tue Apr  5 20:16:13 2022 | Rodolfo | Laser | Discriminator for HF reference signal | For the laser trigger we need to generate a few ns NIM-puls from the HF reference signal.
 Therefore we (Wilfried, Konstantin and me)
 |    | 
| 100 | Tue Apr  5 15:25:47 2022 | Sebastian, Kristian, Pierre-Michel | DAQ | Go4 Conditions for "TDC_stacked_Sig/Ref" histogram | First version of TDC_stacked histograms implemented. 
 Under folder "Conditions" you can now integrate
 |  | 
| 99 | Tue Apr  5 14:51:51 2022 | Kristian | DAQ | dark counts | We shielded the PMTs, i.e., the N2 tube, which improved the Cu PMT background rate.
 
 |  | 
| 98 | Tue Apr  5 13:28:06 2022 | Kristian | DAQ | Spikes in PMT signal | Occasionally, we noticed a spike in the PMT signal. No ions in the ring and at PMT Cu
 was not even supplied with HV. Has to be
 |   | 
| 97 | Tue Apr  5 13:24:40 2022 | Kristian | Detectors | PMT Cu | HV cable was in wrong channel in power supply. Now it is back to the correct position. Checked
 connection at the PMT.
 |  | 
| 96 | Tue Apr  5 12:17:12 2022 | Ragan, Rui-Jiu | DAQ | Instructions to start and stop NTCAP | Attached are the instructions to start and stop data taking using the NTCAP.
 |      |