ID |
Date |
Author |
Category |
Subject |
Text |
|
117
|
Wed Apr 6 22:29:55 2022 |
Patrick | Accelerator | ECooler voltages | ECooler voltages:
[B]06.04:[/B]
|
|
116
|
Wed Apr 6 21:03:25 2022 |
Ken Ueberholz | Detectors | Xuv-Detektor, further information | Some further information regarding the
xuv-detector and its components. |
|
115
|
Wed Apr 6 19:39:08 2022 |
Ken Ueberholz | Detectors | LED installed | The UV-LED of Münster was connected over
channel 8 to the Messhütte. 6V are
supplied by the power supply (picture 2). |
|
113
|
Wed Apr 6 18:51:33 2022 |
Danyal & Carsten | Accelerator | target bump | This afternoon, we found out that Sergey has
also implemented a "target bump".
Although we do not use a target, this bump |
|
112
|
Wed Apr 6 16:01:07 2022 |
BL | Accelerator | ESR settings before adjusting laser: 2022-04-06_14-37-30_ESR_EXP22_02_238U92_Brandau_30March22.C1.txt | # Version: 1.2
# Comment: ParamModi Export at 2022-04-06T14:37:35.957978+02:00[Europe/Berlin]
# Context: ESR_EXP22_02_238U92_Brandau_30March22.C1
|
|
111
|
Wed Apr 6 15:19:29 2022 |
Svea, Shahab | Accelerator | 5s delay implemented before injection | Operators have informed us that for better
stability and operation (and cooperation
with HHT), and after discussing with Sergey, |
|
110
|
Wed Apr 6 14:52:29 2022 |
Rodolfo | Runs | Scraping the ion beam | We are T-scraping the ion beam. |
|
108
|
Wed Apr 6 13:32:57 2022 |
Max, Sebastian | DAQ | LabView Cobra Channel List | channel 0: linux time (epoch time)
channel 1: ms timer
channel 2: E-Cooler Voltage(Ohmlabs)
|
|
107
|
Wed Apr 6 09:30:53 2022 |
Danyal | Accelerator | ESR is blue again - errors are fixed | The ESR is "blue" again.
The errors (scu related) have been fixed. |
|
106
|
Wed Apr 6 08:31:54 2022 |
Danyal & Regina | General | ESR had some errors | Regina noticed that the ESR was "red"
This means that there are some errors.
|
|
105
|
Wed Apr 6 08:06:02 2022 |
Danyal | DAQ | stopped NTCAP data acquisition | I stopped the NTCAP data acquisition at 8
AM.
|
|
104
|
Tue Apr 5 23:55:11 2022 |
Carsten | Runs | Long time measurment with NTCAP | Settings:
Center: 2242.5MHz
RefLevel: -25dB
|
|
103
|
Tue Apr 5 23:07:34 2022 |
Carsten | Accelerator | 229Th89+ identification after re-tuning of the ESR | The ESR was retuned this aftenoon since the
it was unclear if we still sit the 229Th89+
line.
|
|
102
|
Tue Apr 5 20:58:53 2022 |
Wilfried | Laser | Trigger for Laser | Electronic for the timing of the laser puls
optimized. The problem with the broad photodiode
histograms is solved.
|
|
101
|
Tue Apr 5 20:16:13 2022 |
Rodolfo | Laser | Discriminator for HF reference signal | For the laser trigger we need to generate
a few ns NIM-puls from the HF reference signal.
Therefore we (Wilfried, Konstantin and me) |
|
100
|
Tue Apr 5 15:25:47 2022 |
Sebastian, Kristian, Pierre-Michel | DAQ | Go4 Conditions for "TDC_stacked_Sig/Ref" histogram | First version of TDC_stacked histograms implemented.
Under folder "Conditions" you can now integrate |
|
99
|
Tue Apr 5 14:51:51 2022 |
Kristian | DAQ | dark counts | We shielded the PMTs, i.e., the N2 tube, which
improved the Cu PMT background rate.
|
|
98
|
Tue Apr 5 13:28:06 2022 |
Kristian | DAQ | Spikes in PMT signal | Occasionally, we noticed a spike in the PMT
signal. No ions in the ring and at PMT Cu
was not even supplied with HV. Has to be |
|
97
|
Tue Apr 5 13:24:40 2022 |
Kristian | Detectors | PMT Cu | HV cable was in wrong channel in power supply.
Now it is back to the correct position. Checked
connection at the PMT. |
|
96
|
Tue Apr 5 12:17:12 2022 |
Ragan, Rui-Jiu | DAQ | Instructions to start and stop NTCAP | Attached are the instructions to start and
stop data taking using the NTCAP. |
|