HOME
ESR
EXPERIMENTS
LABS etc
E121
E127
E132
E125
E143
laser_cooling_2021
E142
Ê128
E146
E0052
E0018
E0028
E0038
Nuclear hyperfine mixing in 229Th89+, Page 8 of 12
Not logged in
Find
|
Login
|
Help
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Category --
Analysis
Calibration
DAQ
Laser
General
Runs
Detectors
Accelerator
233 Entries
Goto page
Previous
1
,
2
,
3
...
7
, 8,
9
,
10
,
11
,
12
Next
All
ID
Date
Author
Category
Subject
Text
100
Tue Apr 5 15:25:47 2022
Sebastian, Kristian, Pierre-Michel
DAQ
Go4 Conditions for "TDC_stacked_Sig/Ref" histogram
First version of TDC_stacked histograms implemented.
Under folder "Conditions" you can now integrate
105
Wed Apr 6 08:06:02 2022
Danyal
DAQ
stopped NTCAP data acquisition
I stopped the NTCAP data acquisition at 8
AM.
108
Wed Apr 6 13:32:57 2022
Max, Sebastian
DAQ
LabView Cobra Channel List
channel 0: linux time (epoch time)
channel 1: ms timer
channel 2: E-Cooler Voltage(Ohmlabs)
119
Thu Apr 7 00:36:36 2022
Uwe
DAQ
Threshholds and shaping Mesytec for ADC
122
Thu Apr 7 03:06:15 2022
Patrick
DAQ
DAQ file sizes
The file sizes of DAQ1 (229Thor) and DAQ2
(229Th, "Carstens DAQ") are different.
During 20min of laser scanning DAQ1 saves
123
Thu Apr 7 03:09:36 2022
Carsten
DAQ
NTCAP running since 02:40
124
Thu Apr 7 03:44:21 2022
Patrick
DAQ
Measurement procedure
[U][B]Measurement procedure[/B][/U]
125
Thu Apr 7 04:10:18 2022
Ken Ueberholz
DAQ
Corrected cabling DAQ 2
A lot of cables were wrongly or not
connected to the DAQ 2.
127
Thu Apr 7 05:23:50 2022
Patrick
DAQ
How To Start MBS for DAQ2 (Carstens DAQ)
(MBS server should be running at the LXG0155
machine. If not you will get an error message.
Then start the server - last command in console)
128
Thu Apr 7 05:44:40 2022
Pierre-Michel, Ragan
DAQ
NTCAP settings
Carrier Frequency: 244M
IQ Rate: 10M
reference Level: -30
130
Thu Apr 7 07:40:09 2022
Danyal, Max, Sebastian
DAQ
No beam and DAQs crashed
since shortly after 7 AM we have no beam in
the ESR
(reason unclear)
133
Thu Apr 7 09:23:18 2022
Sebastian
DAQ
DAQ1 & DAQ2 - 1kHz and delayed cs removed
Questionable 1kHz and delayed common stop
signals has been removed.
140
Thu Apr 7 15:18:25 2022
Danyal & Sebastian
DAQ
DAQ channels
We checked again the cables for both DAQs
(on Carsten's kind request)
146
Fri Apr 8 01:18:51 2022
Ken Ueberholz
DAQ
TODO: DAQ improvements
For somebody who knows the DAQ1 code: Go4
resets the histograms with each laser step.
Can there be additional histograms where
147
Fri Apr 8 01:48:57 2022
Patrick
DAQ
Bugged Trending plots?
The wavelengths/frequencies shown in the graph
in the labview window do not match the wavelengths/frequencies
in go4.
153
Fri Apr 8 08:40:06 2022
Sebastian
DAQ
DAQ improvement
Concerning ID 146 a new histogram for accumulating
data (no cleaning histograms) can be found
under
162
Fri Apr 8 14:12:57 2022
morning shift
DAQ
timing for h=1
The timing for h=1 has been set up
The time window is now twice as large as
163
Fri Apr 8 14:14:28 2022
Kristian
DAQ
Delay of bunch RF
The bunch HF is now fed through a delay to
shift the stop trigger relative to the PMT
signal. The delay generator is placed directly
164
Fri Apr 8 14:43:50 2022
Wilfried
DAQ
laser timing - Q-switch start
below are my notes concerning laser timing
/ Q-switch start
170
Fri Apr 8 17:57:45 2022
Konstantin
DAQ
Laser scanning
[TABLE border="1"]
Goto page
Previous
1
,
2
,
3
...
7
, 8,
9
,
10
,
11
,
12
Next
All
ELOG V3.1.5-fc6679b