235
|
Fri Apr 15 20:43:18 2022 |
Konstantin | Laser | Dye changed | Dye of the laser system has been changed.
UV laser power increased from ~8 mJ to 11
mJ pulse energy. |
|
67
|
Sat Apr 2 17:47:16 2022 |
Ken Ueberholz | | Telefon, Gästehaus | My guesthouse phone number: 06159-71-2957 |
|
73
|
Sun Apr 3 00:41:45 2022 |
Ken Ueberholz | | Xuv-Detektor Signale | The Xuv-detector cabel channels seem to be
wrongly labeled in the Messhütte (see
|
|
81
|
Sun Apr 3 15:34:34 2022 |
Ken Ueberholz | | Xuv-Detektor CFD-treshhold | I co controlled all detector signals and
adjusted the threshold to be just above
the noise. I will double check this when |
|
115
|
Wed Apr 6 19:39:08 2022 |
Ken Ueberholz | Detectors | LED installed | The UV-LED of Münster was connected over
channel 8 to the Messhütte. 6V are
supplied by the power supply (picture 2). |
|
116
|
Wed Apr 6 21:03:25 2022 |
Ken Ueberholz | Detectors | Xuv-Detektor, further information | Some further information regarding the
xuv-detector and its components. |
|
84
|
Mon Mar 24 06:22:21 104 |
Ken Ueberholz | Detectors | XUV-Detector Rates | Count rates were measured for the XUV-
detector for a full circle:
Cathode: -5V, shields: 0V, main coil 8A, |
|
37
|
Tue Mar 29 12:47:26 2022 |
Ken Ueberholz | | Parameter setting for XUV and copper mirror detector | Some Default Settings for the XUV
Detector. The copper
mirror should always move fully in.
|
|
85
|
Mon Apr 4 00:19:16 2022 |
Ken Ueberholz | DAQ | FirstTests | New measurement:
Start: About 00:12
Stop: About 00:43
|
|
125
|
Thu Apr 7 04:10:18 2022 |
Ken Ueberholz | DAQ | Corrected cabling DAQ 2 | A lot of cables were wrongly or not
connected to the DAQ 2.
|
|
129
|
Thu Apr 7 05:55:17 2022 |
Ken Ueberholz | Detectors | XUV-Detector Mesytec crash | When the XUV-detector has to shut down unexpectedly,
it can happen that the Mesytek power supply
crashes and can't be
|
|
146
|
Fri Apr 8 01:18:51 2022 |
Ken Ueberholz | DAQ | TODO: DAQ improvements | For somebody who knows the DAQ1 code: Go4
resets the histograms with each laser step.
Can there be additional histograms where |
|
41
|
Thu Mar 31 13:28:17 2022 |
Jan Glorius | DAQ | DAQ-2 cabling docu | newest version V2 - valid since Mo 04.April
2022 |
|
62
|
Sat Apr 2 01:27:25 2022 |
Jan Glorius | Runs | test runs 02.04.2022 | Beam settings:
primary beam
copper stripper
|
|
90
|
Mon Apr 4 17:26:48 2022 |
Jan Glorius | DAQ | MSCF shaper settings | attached are the current shaper settings.
list of currently connected channels:
|
|
15
|
Thu Mar 10 15:20:26 2022 |
Jan | DAQ | analog branch signal patches to Messhütte | The additional signals from PMTs and XUV detector
needed for spectroscopic analysis in the
second DAQ are patched to AP Messhütte (MH) |
|
27
|
Mon Mar 21 21:48:46 2022 |
Jan | DAQ | MesyTec Shaper Control | The MesyTec Shaper & Constant Fraction (MSCF)
is used to process the PMT/det signals for
the ADC in the second DAQ.
|
|
156
|
Fri Apr 8 09:33:52 2022 |
Dayshift 1 8.4.2022 | | Reference Measurements | DAQ1: lxg1297:/data.local2/BeamTimeTh22/
DAQ2: lxg0155:/data.local2/E142/
LMD file name DAQ1:229Thor
|
|
132
|
Thu Apr 7 08:43:19 2022 |
Danyal, Yuri, Ragan | Accelerator | again no injection in ESR - ESR kicker problem | we had no injections in the ESR again
it turned out that the injection kicker of |
|
130
|
Thu Apr 7 07:40:09 2022 |
Danyal, Max, Sebastian | DAQ | No beam and DAQs crashed | since shortly after 7 AM we have no beam in
the ESR
(reason unclear)
|
|