IDup Date Author Category Subject
  43   Fri May 7 10:46:40 2021 YuriAcceleratorGE02DS3HG
The scraper is blocked at -10 mm and -unfortunately- blocks the beam in the ESR. Uli Popp is taking care.
  44   Fri May 7 11:40:20 2021 Ragan, Andrew, YuriGeneralScraper is fixed - optimisation stage
Scraper is fixed, we start again. Scraper open to let everything through
  45   Fri May 7 12:37:35 2021 Ragan, Andrew, Yuri, AlexGeneralBack with beam
We are back with the beam in the ESR since 12:30
ALL SCRAPERS ARE IN THE ORIGINAL POSITIONS
E02DS3HG = - 35 mm
EEXDS2HA = - 25 mm
EEXDS1HA = - 25 mm
E01DS_H = - 40 mm

For E02DS3HG a reset in the control system needed to be done.
  46   Fri May 7 14:06:02 2021 YuriAcceleratorSIS kicker failure
  47   Fri May 7 14:33:23 2021 Andrew Ragan Yuri GeneralBeam is back
  48   Fri May 7 16:09:50 2021 YuriAcceleratorStop, change of sextuple settings
  49   Fri May 7 16:17:21 2021 Sergey, Yuri, Wolfram, ShahabRunsnew sextupole setting
new sextupole setting, isomer not visible yet.
  50   Fri May 7 17:02:51 2021 Kanika, Sergey, Yuri, Wolfram, Michael, ShahabRunsnew sextupole setting 2
There is new sextupole settings, but the scrapers remain like last night (Helmut setting last night.)
  51   Fri May 7 17:12:14 2021 Kanika, Sergey, Yuri, Wolfram, Michael, ShahabRunsEnergy change -6 MeV/u
changed the energy down to 435 MeV/u
  52   Fri May 7 17:12:52 2021 Kanika, Sergey, Yuri, Wolfram, Michael, ShahabRunstrigger time back to 50%
changed trigger time back to 50%

last file with 1% trigger: 

245 MHZ 2021.05.07.16.07.03.493
410 MHz 2021.05.07.17.07.21.104


p.s. remember the 245 Analyzer has a 1 hour offset in time stamp because of daylight saving time in win10 setting
  53   Fri May 7 17:35:22 2021 Kanika, Sergey, Yuri, Wolfram, Michael, ShahabRunsEnergy change +6 MeV/u
We will now go up in energy to 447 MeV (+6 MeV) from the original energy

last file name with previous energy:

245: 2021.05.07.16.33.47.178
410: 2021.07.05.17.34.04.780
  54   Fri May 7 18:08:35 2021 Kanika, Sergey, Yuri, Wolfram, Michael, ShahabRunsgoing back to the original energy
going back to the original energy 441 MeV/u

last filenames with the previous energy:

245: 2021.05.07.17.07.00.543
410: 2021.05.07.18.07.18.037
  55   Fri May 7 18:43:13 2021 Kanika, Michael, ShahabRunscave M experiment needs more spills
our pattern causes beam loss while scanning the biological probes in the Cave M bio experiment. They loose every other spill due to high request rate from ESR.

For the next 2 hours, the operators have changed the spill pattern that as long as they are scanning , we get only every 1 minute, otherwise we get our 15 seconds as usual.

after two hours this situation should be tuned back to the original spill pattern.
Attachment 1: rep.jpg
rep.jpg
  56   Fri May 7 19:56:10 2021 Kanika, Michael, ShahabRunsZOOM session restart
restart zoom session
  57   Fri May 7 20:28:32 2021 Kanika, Michael, ShahabAnalysisSome pictures from the 410 detector
some pics.
Attachment 1: E143-410MHz-2021.05.07.20.21.32.783.tiq.png
E143-410MHz-2021.05.07.20.21.32.783.tiq.png
Attachment 2: E143-410MHz-2021.05.07.20.21.44.827.tiq.png
E143-410MHz-2021.05.07.20.21.44.827.tiq.png
Attachment 3: E143-410MHz-2021.05.07.20.21.56.869.tiq.png
E143-410MHz-2021.05.07.20.21.56.869.tiq.png
Attachment 4: E143-410MHz-2021.05.07.20.22.08.911.tiq.png
E143-410MHz-2021.05.07.20.22.08.911.tiq.png
Attachment 5: E143-410MHz-2021.05.07.20.22.20.952.tiq.png
E143-410MHz-2021.05.07.20.22.20.952.tiq.png
Attachment 6: E143-410MHz-2021.05.07.20.22.32.993.tiq.png
E143-410MHz-2021.05.07.20.22.32.993.tiq.png
Attachment 7: E143-410MHz-2021.05.07.20.22.45.037.tiq.png
E143-410MHz-2021.05.07.20.22.45.037.tiq.png
Attachment 8: E143-410MHz-2021.05.07.20.22.59.920.tiq.png
E143-410MHz-2021.05.07.20.22.59.920.tiq.png
Attachment 9: E143-410MHz-2021.05.07.20.23.17.103.tiq.png
E143-410MHz-2021.05.07.20.23.17.103.tiq.png
  58   Fri May 7 20:34:27 2021 Kanika, Michael, ShahabRunsback to 15 sec recording
now we are going back to 15 sec operation. Cave M (bio) operation is over
  59   Fri May 7 22:00:36 2021 ChrisAcceleratorbrief beam loss
Brief interruption in beam, ~21:42-21:51.
  60   Fri May 7 22:48:33 2021 ChrisGeneralstill running...
In anticipation of the imminent shift change, a snapshot of how things look.
Attachment 1: E143-245MHz-2021.05.07.21.46.10.889.tiq.png
E143-245MHz-2021.05.07.21.46.10.889.tiq.png
Attachment 2: Zoom_screenshot.PNG
Zoom_screenshot.PNG
  61   Fri May 7 23:08:44 2021 Michael, KanikaAcceleratorBeam issues for short duration
The beam was lost for a few minutes from 23:01 to 23:06. It is back now.
  62   Sat May 8 00:38:55 2021 Philipp, MartaGeneralScreenshot
Attachment 1: Screenshot_2021-05-08_at_00.32.16.png
Screenshot_2021-05-08_at_00.32.16.png