Fri Jul 2 17:31:04 2021, Liliana, General, status
|
at 17:20 intensity was suddenly reduced.
Operators checked. Intensity was a bit low and fluctuating for a while (8e8 to 1e9)
Intensity (1.5e9) was recovered at 18:16 |
Fri Jul 2 19:06:18 2021, Liliana, DAQ, NTCAP status
|
The latest recorded tdms files:
p:\E143\sc\SC_2021-06-30_23-27-45\0000600
p:\E143\iq\IQ_2021-06-30_23-27-34\0002931
2. The rest space on the drive "p:\" : 23,4 TByte |
Fri Jul 2 20:01:16 2021, Liliana, Runs, Some plots from the Br setting 6x
|
|
Fri Jul 2 21:07:31 2021, Liliana, DAQ, NTCAP status
|
The latest recorded tdms files:
p:\E143\sc\SC_2021-06-30_23-27-45\0000627
p:\E143\iq\IQ_2021-06-30_23-27-34\0003062
2. The rest space on the drive "p:\" : 22,9 TByte |
Tue Jun 29 21:12:15 2021, Kanika, Shahab, Runs, Moving the resonance frequency of the 245 MHz resonator
|
moving in the plungers:
before: 400
after: 200 |
Tue Jun 29 21:15:01 2021, Kanika, Shahab, Runs, lost beam problem Unilac
|
cooling water in UNILAC is out |
Fri May 7 17:02:51 2021, Kanika, Sergey, Yuri, Wolfram, Michael, Shahab, Runs, new sextupole setting 2
|
There is new sextupole settings, but the scrapers remain like last night (Helmut setting last night.) |
Fri May 7 17:12:14 2021, Kanika, Sergey, Yuri, Wolfram, Michael, Shahab, Runs, Energy change -6 MeV/u
|
changed the energy down to 435 MeV/u |
Fri May 7 17:12:52 2021, Kanika, Sergey, Yuri, Wolfram, Michael, Shahab, Runs, trigger time back to 50%
|
changed trigger time back to 50%
last file with 1% trigger:
245 MHZ 2021.05.07.16.07.03.493
410 MHz 2021.05.07.17.07.21.104
p.s. remember the 245 Analyzer has a 1 hour offset in time stamp because of daylight saving time in win10 setting |
Fri May 7 17:35:22 2021, Kanika, Sergey, Yuri, Wolfram, Michael, Shahab, Runs, Energy change +6 MeV/u
|
We will now go up in energy to 447 MeV (+6 MeV) from the original energy
last file name with previous energy:
245: 2021.05.07.16.33.47.178
410: 2021.07.05.17.34.04.780 |
Fri May 7 18:08:35 2021, Kanika, Sergey, Yuri, Wolfram, Michael, Shahab, Runs, going back to the original energy
|
going back to the original energy 441 MeV/u
last filenames with the previous energy:
245: 2021.05.07.17.07.00.543
410: 2021.05.07.18.07.18.037 |
Fri May 7 18:43:13 2021, Kanika, Michael, Shahab, Runs, cave M experiment needs more spills
|
our pattern causes beam loss while scanning the biological probes in the Cave M bio experiment. They loose every other spill due to high request rate from ESR.
For the next 2 hours, the operators have changed the spill pattern that as long as they are scanning , we get only every 1 minute, otherwise we get our 15 seconds as usual.
after two hours this situation should be tuned back to the original spill pattern. |
Fri May 7 19:56:10 2021, Kanika, Michael, Shahab, Runs, ZOOM session restart
|
restart zoom session |
Fri May 7 20:28:32 2021, Kanika, Michael, Shahab, Analysis, Some pictures from the 410 detector 9x
|
some pics. |
Fri May 7 20:34:27 2021, Kanika, Michael, Shahab, Runs, back to 15 sec recording
|
now we are going back to 15 sec operation. Cave M (bio) operation is over |
Sun May 9 23:28:25 2021, Kanika, Alex, Wolfram, Helmut, Shahab, Runs, return with the Ge setting of the last night
|
starting filenames:
E143-410MHz-2021.05.09.23.28.24.018.tiq
E143-245MHz-2021.05.09.22.28.12.904.tiq |
Mon May 10 06:16:31 2021, Kanika, Alex, Shahab, Runs, Recording broad band spectra with 410
|
doing some broadband spectra recording with the 410 MHz detector, for the purpose of future confirmation of identification lines. |
Mon May 10 06:35:58 2021, Kanika, Alex, Shahab, Runs, going back to shot by shot recording with 410 detector
|
going back to shot by shot recording with 410 detector |
Mon May 10 00:51:38 2021, Kanika, Alex, RuiJiu, General, No beam in SIS
|
The beam was lost in SIS about 5 mins ago due to the failure of HF cavities. Operators are trying to solve the problem. |
Mon May 10 01:01:59 2021, Kanika, Alex, RuiJiu, General, Beam is back
|
The issue has been resolved and the beam is back since 00:56. |
|