Sat May 15 09:50:31 2021, Team, Runs, Laser cooling of....
|
H=2
H=7
H=10
|
Sat May 15 09:23:52 2021, Sebastian, Accelerator, Ekühler
|
Tab "Kühler Elektronenstrahl"
An Gerät schicken |
Sat May 15 09:22:41 2021, Sebastian , Accelerator, Ekühler
|
Settings für Ekühler an und aus in SC4 und
5 |
Sat May 15 06:51:16 2021, Night Shift Sebastian/Max/Noah, General, Different Laserscantypes
|
We use different scan types (manual scan) or constant laser wavelengths to check the effects of laser cooling in the Schottky diagrams (fluorescence can
not be seen in the detector), for different bunching amplitudes and frequencies:
- Scan from 1028.950 -> 1028.940, stepsize 0.001 every 10 sec
|
Sat May 15 03:39:16 2021, Team, General, actual revolution frequency
|
frev = 1,2912735 MHz |
Fri May 14 22:20:37 2021, Team, Accelerator, ESR Closed - BEAM #ON!
|
|
Fri May 14 22:04:25 2021, Team, Accelerator, ESR OPEN ; NO BEAM -> Reset cooling device
|
we had to open the ESR to reset a cooling device |
Fri May 14 21:43:40 2021, Sebastian, General, "problems accelerator"
|
There are cooling problems of some accelerator devices
short break, hopefully :)
Laser is switched of for some rest |
Fri May 14 16:37:01 2021, Benedikt, General, Status update
|
Right now, we have to adjust the ion beam a bit to overlap better with the laser beam.
We keep the laser wavelength at resonance with the ions and try to optimize the fluorescence signal on the XUV detector while moving the ion beam. |
Fri May 14 11:01:33 2021, Benedikt, Calibration, Laser Beam adjusted
|
The laser beam was adjusted in his position to overlap better with the ions.
Ion beam is destroyed at scraper position 1VO 6 mm and 2VO 4 mm; the laser beam looses half its power at 1VO 6mm and 2VO 4 mm.
|
Fri May 14 09:40:04 2021, Nightshift, Runs, Ecooling vs laser wavelength shift, coasting beam, laser stronger than Ecooling
|
Last three pictures where taken after
first laser ion beam overlap adjustments
|
Fri May 14 09:38:43 2021, Nightshift, Runs, Coasting beam, ecooler on, scanning laser
|
|
Fri May 14 09:38:04 2021, Nightshift, Runs, Coasting beam, scanning laser, ecooler on
|
|
Fri May 14 09:35:20 2021, Nightshift, Runs, Coasting beam, scanning laser, ecooler on
|
|
Fri May 14 09:00:55 2021, Sebastian, General, UNILAC Problems
|
~30 min downtime
--> LASER ADJUSTEMENTS! |
Fri May 14 08:55:53 2021, Sebastian, General, ToDO 14.5 ...so far
|
1.) ion lasser overlap and scraper test
2.) change bunching frequency to middle of ecooled coasting beam
|
Fri May 14 07:33:42 2021, Team #Night, General, ecooler central frequency shifted relative to bunch central frequency
|
|
Fri May 14 07:20:18 2021, Team #Night, General, actual bunching frequency
|
25,82556 MHz
h = 20 |
Fri May 14 06:35:55 2021, Team #Night, General, Adjustment of Laser
|
we increased the height of the laser beam
TEM Settings
|
Fri May 14 06:34:45 2021, Team #Night, Analysis, DSG821 IP
|
140.181.104.108 |