  16   Tue Jun 17 16:33:16 2025 Carsten, SimonDAQGate Q-swtich
The gate generator of the Q-switch signal for the Vuprom TDC was set to 10ms.
  74   Sun Jun 29 15:53:45 2025 Carsten, SimonAcceleratorNo scans possible
15:45 Right now, we are waiting for stable conditions again. There are problems with both the ion source and the accumulation in SIS.

16:20 SIS and source look better now, but now ESR makes trouble. The stacking looks off and after deceleration and cooling barely any Th-ions are stored. The positions of the scrapers seem to be wrong. Carsten is trying to fix it.
  75   Sun Jun 29 18:04:11 2025 Carsten, SimonRunsLate shift 29.06.
Time Part. Det. Int SIS-intensity accumulations in ESR cooler-HV PTB K250 cooler-HV PTB red cooler-HV orange LMD-DAQ1 Files LMD-DAQ2 Files scan range(nm) number of positions dwell time (laser shots) n loops checked laser position comments
18:10 18000 2.8e9 30 104525 - - 287 314 548.51 - 548.01 201 15 3 yes Part. Det Int. after 3 loops
18:26 14000 2.8e9 30 104525 - - 288 315 548.51 - 548.01 201 15 2 yes Part. Det Int. after 2 loops
18:41 16000 2.8e9 35 104525 - - 289 316 548.51 - 548.01 201 15 2 yes -
18:57 21000 2.0e9 40 104525 - - 290 317 548.51 - 548.01 201 15 3 yes -
19:14 13000 2.0e9 40 104525 - - 291 318 548.51 - 548.01 201 15 3 yes -
19:53 15000 2.6e9 35 104525 - - 292 319 548.51 - 548.01 201 15 2 yes -
20:08 15000 2.0e9 40 104525 - - 293 320 548.51 - 548.01 201 15 2 yes -
20:25 19000 2.4e9 40 104525 - - 294 321 548.51 - 548.01 201 15 3 yes -
20:44 3000 2.4e9 45 104525 - - 295 322 548.51 - 548.01 201 15 2 yes very low intensity, so we kept Go4 off and only ran mbs
21:04 23000 2.8e9 30 104525 - - 296 323 548.51 - 548.01 201 15 3 yes
21:21 24000 2.8e9 30 104525 - - 297 324 548.51 - 548.01 201 15 3 yes
21:39 18000 2.8e9 30 104525 - - 298 325 548.51 - 548.01 201 15 3 yes
21:57 6400 2e9 40 104525 - - 299 326 548.51 - 548.01 201 15 2 yes low intensity, no Go4


All Particle detector values are after the respective number of scans.

AT 1700 Bernd came in since we couldn't properly accumulate. Bernd adjusted the deceleration HF and slightly changed the extraction kicker from 1.9mrad to 1.7 mrad. High intensity of 229/89.

At 19:35 again problems with transmission SIS -> ESR. Put the Kciker (GTE3Mu1/HIKICK) back to 1.9 mrad (orignal value).
  27   Wed Jun 18 20:24:01 2025 Carsten, Shahab, Ragandeep, Danyal et al. (the dayshift) and ESR crewAccelerator229Th89+ identification
We believe to have identified the 237U92+ and the 229Th89+ peaks. 

Using the Schottky resonator at about 244 MHz and taking the 123rd harmonic: 
The Schottky peak of 237U92+ should be at 242.7975 MHz and the one of 229Th89+ at 242.8494 MHz. 
The peaks should be ~52 kHz apart.

We have used:  
gamma_t	= 2.355 
alpha_p = 0.18 
  19   Wed Jun 18 00:56:28 2025 Carsten, Rodolfo, Anton, Alexis, Esther beam overlap with t-scrapers
When testing the overlap between laser and ion beam we observed the following positions:

motorion beam position (mm) from outsideion beam position (mm) from inside
GECEDS1VU 0 6.5
GECEDS1HA -22.5 -13.5
GECEDS2VU 1 8.5
GECEDS2HA -20.5 -10


Note: To move GECEDS1VU the corresponding horizontal drive (GECEDS1HA) has to be at 2 mm.
  58   Tue Jun 24 18:49:18 2025 Carsten, Rima, Nils, SimonRunsSecond attempt (Late shift 24.06.)

Scan parameters:
scan range551.91 - 549.41
positions501
step width0.005nm
advance after15 rising edges
iterations1
rev. frequency 1.54315e6



Time Part. Det. Int SIS-intensity accumulations in ESR cooler-HV PTB K250 cooler-HV PTB red cooler-HV orange LMD-DAQ1 Files LMD-DAQ2 Files scan range(nm) number of positions dwell time (laser shots) n loops checked laser position comments
19:03 14800 2.7e9 60 104510 104514 104514 118 147 551.91 - 549.41 501 15 1 yes TE beamline slits -30 +30
19:22 14900 2.7e9 60 104510 104514 104514 119 148 551.91 - 549.41 501 15 1 yes -
19:40 14500 2.7e9 60 104510 104514 104514 120 149 551.91 - 549.41 501 15 1 yes TE beamline slits -20 +20
19:58 13800 2.0e9 60 104510 104514 104514 121 150 551.91 - 549.41 501 15 1 yes -
20:18 10800 2.1e9 60 104510 104514 104514 122 151 551.91 - 549.41 501 15 1 yes -
20:37 10100 2.1e9 60 104510 104514 104514 123 152 551.91 - 549.41 501 15 1 yes -
20:56 10500 2.1e9 60 104510 104514 104514 124 153 551.91 - 549.41 501 15 1 yes -
21:15 9000 2.2e9 60 104510 104514 104514 125 154 551.91 - 549.41 501 15 1 yes after this we change to 45 injections to give more cave access to HHT
21:37 11500 2.3e9 45 104510 104514 104514 126 155 551.91 - 549.41 501 15 1 yes small pause for HHT
22:13 13400 2.5e9 45 104510 104514 104514 127 156 551.91 - 549.41 501 15 1 yes small pause for HHT, cooling time in SC7 increased from 20s to 28 s
  45   Sun Jun 22 18:47:23 2025 Carsten, Peter, Marek, SimonDAQPMT and particle detector settings
Final voltages and thresholds for the PMTs and particle detectors before the first scan:

Detector voltage (kV) threshold (mV) mesytec
particle detector 1.35 100 -
PMT north 2.7 10 16
PMT mid 2.65 10 16
PMT south 2.7 10 16


All other mesytec thresholds remain unchanged and can be found in entry 7.

Important note: Ch0 of the PMT power supply broke, so we moved PMT north to CH3.
Current setup:
CH1: PMT mid
CH2: PMT south
CH3: PMT north
  41   Sat Jun 21 18:00:49 2025 Carsten, Peter, Danyal, Kristian, Marek DetectorsPMT signals
Carsten and Kristian changed (18:00) the thresholds of PMT north and PMT middle in the ESR cave. 
See picture below. The effect is negligible. 


Carsten will now (18:05) change the channel of the pre-amp of PMT north. 
  40   Sat Jun 21 17:00:10 2025 Carsten, Peter, Danyal, Kristian, MarekDetectorsPMT north exchanged
We noted that the dark countrate of PMT north is about 20x higher than that of PMT middle. 

We went into the ESR cave to look for stray light. 
We decided to put a black cloth over all the PMTs. 
Also we made the tubes of the N2 airflow to the PMTs black (tape around). 
This did not make a significant change. 

We exchanged PMT north (same type 9423B) to see if that made a difference. 
It did not really change either. 

PMT north = 2650 V 
PMT middle = 2700 V 

The first picture below shows the dark rates for these two voltages. 

At about 17:00 we changed the voltage of PMT north to 2700 V. 
This did not change anything. 


Carsten swapped the cables of PMT north and PMt middle (inside ESR, before the amps) at 17:14.
The second picture below shows the result of that. 
Now black and red are exchanged. 


Carsten swapped the cables back again (17:20). 
Carsten and Kristian will look at the PMT signals in the ESR cave. 
  62   Thu Jun 26 19:01:46 2025 Carsten, Jan, SimonRunsLate shift 26.06.

Scan parameters:
scan range551.91 - 549.41
positions501
step width0.005nm
advance after15 rising edges
iterations1
rev. frequency 1.54315e6




Time Part. Det. Int SIS-intensity accumulations in ESR cooler-HV PTB K250 cooler-HV PTB red cooler-HV orange LMD-DAQ1 Files LMD-DAQ2 Files scan range(nm) number of positions dwell time (laser shots) n loops checked laser position mesytec rate ok comments
19:15 23000 1.5-3.5 e9 33 104522 104526 104526 142 170 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
19:41 19000 3.3e9 30 104522 104526 104526 143 171 551.91 - 549.41 501 15 1 yes yes TE slits at -7 and +7
20:08 17500 3.3e9 25 104522 104526 104526 144 172 551.91 - 549.41 501 15 1 yes yes -
20:24 7000 3.3e9 25 104522 104526 104526 145 173 551.91 - 549.41 501 15 1 yes yes low Part. Det. Int maybe due to wrond position of part. det.
21:19 7000 3.5e9 25 104522 104526 104526 146 174 551.91 - 549.41 501 15 1 yes yes TE slits at -8 and +8
21:40 14000 3.3e9 25 104522 104526 104526 147 175 551.91 - 549.41 501 15 1 yes yes adjusted particle detector position
22:04 19500 3.3e9 40 104522 104526 104526 148 176 551.91 - 549.41 501 15 1 yes yes


After the scan at 22:04 teh FCU new was new calibrated. For this MEdusa was stopped and reopened in the laser lab. This stops the Labview server, and as a consequence the the connection to the MBS was lsot. Then, MBS needs to be restarted and the online data is cleared. Such an intervention should avoided as good as possible.
A pratical solution for beamtimes with such long data taking is still pending.
When trying to restart MBS MBS completlz hung up also resl etc did not work. Crate powered down and restarted.
  63   Thu Jun 26 21:27:34 2025 Carsten, Jan, SimonCalibrationTiming
We checked the timing (before the start of the measurement cycle documented below).
Timing and measurement window are attached.
  7   Wed Jun 11 16:44:39 2025 Carsten, JanDetectorsDetector voltages and thresholds for DAQ2 (Mesycontrol)
Voltages (2650v) for the small band 9423 is ok. Signals are nicely separated from background, thresholds can be easily set.
For the broadband 9422 the voltage is by far too low. Signals and BG are barely separated.
Increased voltage from 1500V to 1750V (according to datasheet Vmax = 2500V, 1500 V is the min voltage for gain 1e6...).
Now signals are better separated - threshold with mesycontrol can be set in such a way that the dark count rate is 300 - 400 Hz (was > 1kHz).
For detector south, the threshold in DAQ1 has to be readjusted.

Below are the settings for Mesytec CFD. Internally the 2nC chips (x 20 ??? ) are used for both groups. Please note that thre are also 20nC chips in "parking position" (lower amplfication).
The Mesytec PMT CFD Version uses "nC" chips while the other Mesytec Shapers "gain / amplification", i.e. chips labeled with 20 are x20 and have a large amplification while the "nC" chips give the full scale range , aka the 20nC is tghe small amplification.

Note as well: Externally, the channel numbering starts with "1" while the Mesycontrol starts with "0".

The sum of all Mesytec signals defines the gate for the ADC.
Group 4-7 are the x100 signals (similar to Vuprom TDC). These signals go to the 25ps TDC and are used for timing, and to the ADC.
Group 0-3 is x10; thresholds are artificially set slightly too high, signals are used in the ADC only. Since these are the same signals as in the x100 group, their (correct) gate signals can be used in the ADC. The x10 capture also the very high signals.

ch 0(1): PMT South x10 (A).
ch 1(2): PMT Mid x10 (B).
ch 2(3): PMT North x10 (C).

ch 4(5): PMT South x100 (B).
ch 5(6): PMT Mid x100 (D).
ch 6(7): PMT North x100 (F).
  8   Wed Jun 11 17:33:04 2025 Carsten, JanDAQDAQ2 - new computer , new directories (lxg0155 doesn't work reliably)
LXG0155 (used in form er beamtimes) crashes and hangs and hangs eventually.

Lgx0155 is shut-down and is replaced by lxg3113.

For the experiment (DAQ2) still user stoe_exp can be used (Credits - see monitor).
MBS runs on r4l-68 with user atplaser: (/esr/usr/atplaser/) mbsrun/E0052/DAQ2

The data is stored on the ATP NAS (atprfio.gsi.de). (instead of local disk).

In the home directory there is link to access the data (u/stoe_exp/nas/229Th2025 ; ~/nas/229Th2025)
( sshfs -o directport=7777 atprfio.gsi.de:/mnt/raw.data /u/stoe_exp/nas )


For mbs the correct location on atprfio.gsi.de need to be used (cf. @openfile).i.e.
con rfio atprfio -DISK
and
open file /mnt/raw.data/229Th2025/Th25DAQ2_.lmd .
This is the mountpoint in mbs.
The commands @connectdisk and @openfile are adjusted accordingly.
  46   Sun Jun 22 21:36:48 2025 Carsten, Finn, Zac, EstherRunsFirst laser scans

Scan parameters:
scan range551.91 - 549.41
positions501
step width0.005nm
advance after15 rising edges
iterations1
rev. frequency 1.54315e6


Note: When doing the accumulation in the ESR the particle number (observed in Lassie Monitor) seems to saturate. This is not actually the case but just an effect of the real signal being buried in other species.

Time Part. Det. Int SIS-intensity accumulations in ESR cooler-HV PTB cooler-HV ? LMD-DAQ1 Files LMD-DAQ2 Files scan range(nm) number of positions dwell time (laser shots) n loops checked laser position comments
22:33 10800 1.25e9 60 104513 104509 106 0136 551.91 - 549.41 501 15 1 yes -
22:50 10800 1.3e9 60 104513 104509 107 0137 551.91 - 549.41 501 15 1 yes -
23:07 14000 1.3e9 60 104513 104509 108 0138 551.91 - 549.41 501 15 1 yes -
23:24 11500 1.3e9 60 104513 104509 109 0139 551.91 - 549.41 501 15 1 yes -
23:40 13100 1.3e9 60 104513 104509 110 0140 551.91 - 549.41 501 15 1 yes -
23:57 13100 1.3e9 60 104513 104509 111 0141 551.91 - 549.41 501 15 1 yes -
00:14 12700 1.4e9 60 104513 104509 112 0142 551.91 - 549.41 501 15 1 yes -
00:31 13500 1.4e9 60 104513 104509 113 0143 551.91 - 549.41 501 15 1 yes -
00:48 10700 1.25e9 60 104513 104509 114 0144 551.91 - 549.41 501 15 1 yes -
01:05 - 1.0e9 60 104513 104509 115 0145 551.91 - 549.41 501 15 1 yes BAD FILE(?): beam was killed as some point during the scan, we don't know why; no counts on the particle detector
  59   Tue Jun 24 22:24:36 2025 Carsten, Finn, Hiroshi, Esther, RodolfoRunsData taking (night shift 24.06.)

Scan parameters:
scan range551.91 - 549.41
positions501
step width0.005nm
advance after15 rising edges
iterations1
rev. frequency 1.54315e6


Notes:
1. NTCAP was only started after the fourth scan. The file timestamp is '2025-06-25_00-02-08'.
2. Beam was lost at 03:45 and could not be recovered by the operators. On-call service was called but they have to replace a part, current estimate is 2-3 hours.

Time Part. Det. Int SIS-intensity accumulations in ESR cooler-HV PTB K250 cooler-HV PTB red cooler-HV orange LMD-DAQ1 Files LMD-DAQ2 Files scan range(nm) number of positions dwell time (laser shots) n loops checked laser position comments
22:39 13500 2.4e9 60 104510 104514 104514 128 157 551.91 - 549.41 501 15 1 yes 60 injections, cooling time (SC 7) 28s -> 32s
23:00 11500 2.4e9 45 104510 104514 104514 129 158 551.91 - 549.41 501 15 1 yes 45 injections
23:20 10500 2.4e9 45 104510 104514 104514 130 159 551.91 - 549.41 501 15 1 yes
23:44 9100 2.4e9 45 104510 104514 104514 131 160 551.91 - 549.41 501 15 1 yes
00:05 14000 2.4e9 60 104510 104514 104514 132 161 551.91 - 549.41 501 15 1 yes back to 60 injections
00:28 14300 2.4e9 75 104510 104514 104514 133 162 551.91 - 549.41 501 15 1 yes 75 injections, mesytec channel threshold 0-3 set 255
01:26 13200 2.4e9 75 104510 104514 104514 134 163 551.91 - 549.41 501 15 1 yes there was an interruption at the source, took some time to get the beam back
01:48 10500 2.3e9 75 104510 104514 104514 135 164 551.91 - 549.41 501 15 1 yes
02:10 12400 2.3e9 75 104510 104514 104514 136 165 551.91 - 549.41 501 15 1 yes
02:33 9600 2.4e9 75 104510 104514 104514 137 166 551.91 - 549.41 501 15 1 yes
02:55 10000 2.4e9 75 104510 104514 104514 138 167 551.91 - 549.41 501 15 1 yes
03:18 9600 2.4e9 75 104510 104514 104514 139 168 551.91 - 549.41 501 15 1 yes
  76   Sun Jun 29 22:06:19 2025 Carsten, Alex, HendrikRunsNight shift 29.06.
[TABLE border="1"]
Time | Part. Det. Int | SIS-intensity| accumulations in ESR |  cooler-HV PTB K250 |  cooler-HV PTB red | cooler-HV orange | LMD-DAQ1 Files | LMD-DAQ2 Files | scan range(nm) | number of positions | dwell time (laser shots) | n loops | checked laser position | comments |-
22:16 | 4800 | 2e9 | 30 | 104525 | - | - | 300 | 327 | 548.51 - 548.01 | 201 | 15 | 2 | yes | only few ions, did not start Go4 |-
22:28 | 9000 | 2e9 | 15 | 104525 | - | - | 301 | 328 | 548.51 - 548.01 | 201 | 15 | 2 | yes | After this run: Shaky SIS intensity, cathode is being changed |-
22:53 | 7000 | 2e9 | 35 | 104525 | - | - | 302 | 329 | 548.51 - 548.01 | 201 | 15 | 2 | yes |-|-
[/TABLE] 
23:20 Failure of GE01KP04, GE01KP05, GE01KP22 (or GE01KP24) devices in the ESR.
Problems with gtemu3-hick (??) , take injections since 
01:49 Bernd tried to make things work by switching off and on some of the dipole correction coils. He was even able to get a quite good intensity by leaving one of the coils switched off (although with a slight shift of frequencies visible in Schottky spectrum) but then the ESR electron cooler has failed probably due to problems with the cooling water. So, the decision was taken to stop the measurement at this point. The laser was switched off.
  33   Sat Jun 21 01:40:31 2025 Carsten, Alex, Anton, Rodolfo, HiroshiAcceleratorbeam parameters
The revolution frequency for the measurement condition is: 1.542728 MHz.
The electron cooler voltage is: 104411 V.
  2   Mon Jun 2 16:36:57 2025 CarstenDetectorsMesycontrol
ssh -Y litv-exp@x86l-204
'mesycontrol'
  9   Thu Jun 12 15:53:13 2025 CarstenDAQdata directory and backup disk (WDBook2 RAID)
The data of DAQ1 are stored in the following directory and with the following filenames

open file /data.local2/2025_229Th/2025_229ThDAQ1_ -auto -rfio 
(from @openfile)

The usual @connectdisk, @openfile @closefile are adapted and can be used.

The WDBook RAID0 disk is attached for backup of the data

/media/atplaser/WDBook2/2025E0052daq1
  10   Thu Jun 12 16:27:45 2025 CarstenDAQNTCAP directory
On the NTCAP the directory is changed to 
Q:/E0052