ID Date Author Categorydown Subject
  2   Fri Dec 13 13:44:13 2024 SebastianRunstest
test 123
  50   Fri Feb 28 13:53:06 2025 Tamina, RodolfoRunsIonenbunch
Signal of PMT-Mitte. Recorded with an unstable ion bunch. With approx. 3E8 Ions

The second screenshot is showing a similar signal with 1.8E8 Ions
Attachment 1: Screenshot_Kr_Ionenbunch_2025-02-28_1350.png
Screenshot_Kr_Ionenbunch_2025-02-28_1350.png
Attachment 2: Screenshot_Kr_Ionenbunch_2025-02-28_1445.png
Screenshot_Kr_Ionenbunch_2025-02-28_1445.png
  65   Sat Mar 1 07:10:32 2025 Sebastian, Denise, BenediktRunsErste Messung
Autoscan der Wellenlänge 

Leistung im Laserlabor: 30mW (schwankend)
Daten der Gentects werden hier auf dem Windows Rechner (Gentec NW) und auf Sebastians Laptop (Gentec SW) gespeichert, da die slow control noch eine zeitliche Verzögerung 
aufweist

Scan 1
Start bei 257.175nm 
Ende bei 257.2998nm
Schrittgröße 0.0024nm

Start um 6:53 Uhr am 01.03.2025
Start LMD Krypton0096

Ende um 7:42 Uhr 


Scan 2
Start bei 257.2998nm
Ende bei 257.4246nm
Schrittgröße 0.0024nm 

Start um 8:06 Uhr
Start LMD Krypton0104

Ende um 9:00 Uhr 


Scan 3
Start bei 257.4246nm
Ende bei 257.5494nm
Start LMD Krypton0112

Scan um 10:41 Uhr abgebrochen, da plötzlich keine Ionen mehr im Ring vorhanden sind.


Scan 3.2 (neue Aufnahme von Scan 3)
Start bei 257.4246nm
Ende bei 257.5494nm
Schrittgröße 0.0024nm 

Start um Uhr
Start LMD 

Ende um Uhr
  66   Sat Mar 1 07:14:48 2025 Night shiftRunsTabelle erster Scanbereich 257.175 nm - 257.300 nm
Zeit Scanbereich (nm) Anzahl Laserschritte Start LMD Stop LMD Messdauer (s) Elektronenkuehlung (s) Gentec Files Kommentar
06:53 Uhr 01.03.2025 257.175 - 257.2998 52 krypton0096 krypton0103 10 30 Gentec Suedwest, Scan1_257.175-257.300
08:05 Uhr 01.03.2025 257.2998 - 257.4246 52 krypton0104 krypton0111 10 30 Gentec Suedwest2, Scan2_257.2998-257.4246
10:20 Uhr 01.03.2025 257.4246 - 257.5470 52 krypton0112 krypton0113 10 30 Gentec Suedwest3, Scan3_257.4246-257.5470 10:41 measurement was stopped because beam is gone
11:08 Uhr 01.03.2025 257.4246 - 257.5470 52 krypton0114 krypton0114 10 30 Gentec Suedwest3.2, Scan3_257.4246-257.5494 First wavelength step at 11:08, no ions after fifth step. Scan aborted at 11:16
13:00 Uhr 01.03.2025 257.4246 - 257.5470 52 krypton0115 krypton0118 10 30 - Gentecs are logged automatically now; ecooler voltage 157409.6V, hf frequency is still the same (1.7838817MHz), beam gone at 13:16
15:41 Uhr 01.03.2025 257.4246 - 257.5494 52 krypton0119 krypton0126 10 30 -
16:38 Uhr 01.03.2025 257.5494 - 257.6750 52 krypton0127 krypton0133 10 30 -
1 2 3 4 5 6 7 8 9
  73   Sat Mar 1 18:32:05 2025 JensRunsLaser während Scan
18:30Uhr:
Timestamp im Programm hat gehangen. Kurz im Anzeigefeld markieren und es ging wieder.
Laser Step Counter hat gehangen und lag mit 4Go 20 Steps auseinander. Da es früh genug auffiel wurde der Number of Steps von 52 auf 72 erhöht. Ist also unkritisch wenn es auffällt.
Vllt zusammenhang mit dem Hänger vom Timestamp?

Todo: Programm nach Scan neu starten und im Auge behalten. Am besten immer mal wieder mit Messhütte abgleichen.
Neustart mit zweiten Messzyklus um 18:58Uhr (ID 72)

Scheint nach Neustart keine Probleme zu machen. Falls der Log im Programm immer weiter gefüllt wird könnte das de Ursache für den Hänger sein. Alle paar Stunden den Log mal löschen/neustarten.

Zurücksetzen der Wellenlänge in 0,1nm Schritten klappt sehr gut. LBO Optimierer, ASE-Filter und UV-Optimierer laufen lassen und immer wenn die LBO Temp am Sollwert ankommt weiter drücken.
  83   Mon Mar 3 01:53:18 2025 Sebastian, Denise, BenediktRunsextending the lower wavelength range (no shift)
We will extend the min normal scan range by 3 measurements

Zeit Scanbereich (nm) Anzahl Laserschritte Start LMD Stop LMD Messdauer (s) Elektronenkuehlung (s) Kommentar
2:11 Uhr 03.03.2025 257.0502 - 257.175 52 krypton0367 krypton0367 10 30 Abbruch da Ionen kurz weg waren
2:19 Uhr 03.03.2025 257.0502 - 257.175 52 krypton0368 krypton0374 10 30 auch hier waren bei Laserstep 28 und bei 42 und 52 die Ionen weg
3:11 Uhr 03.03.2025 257.0502 - 257.175 52 krypton0375 krypton0381 10 30 hier etwa 20mW Leistung als Laserleitung im Laserlabor (auch runs vorher), auch hier bei Laserstep 32 waren die Ionen weg
4:10 Uhr 03.03.2025 257.0502 - 257.175 52 krypton0382 krypton0388 10 30 ab hier etwa 30mW Laserleistung, bei Laserstep 7 und 43 waren Ionen weg
  84   Mon Mar 3 01:58:27 2025 Sebastian, Denise, BenediktRunsLebensdauer Ionen
Lebensdauer der Ionen wurde für etwa 1000s vermessen ohne Laser 
(geblockt)
-> XUV Anode und DC Trafo 
Startionenstrom etwa 1.5 e8
Pattern in SC6 angehalten
LMD 0365 bis 0366
Attachment 1: 00bc9fcd-d74c-4de8-bae8-b2bdc77fdbcd.jpeg
00bc9fcd-d74c-4de8-bae8-b2bdc77fdbcd.jpeg
Attachment 2: af0b9db5-e5d5-44ca-8944-b636ae2dc83c.jpeg
af0b9db5-e5d5-44ca-8944-b636ae2dc83c.jpeg
Attachment 3: e507844a-1f8f-4ac9-a07b-1f2127e8cfad.jpeg
e507844a-1f8f-4ac9-a07b-1f2127e8cfad.jpeg
Attachment 4: 406da35f-60df-4a25-944b-fb9a2c8c1f16.jpeg
406da35f-60df-4a25-944b-fb9a2c8c1f16.jpeg
Attachment 5: f7db1949-b939-4ece-a922-2370527be695.jpeg
f7db1949-b939-4ece-a922-2370527be695.jpeg
Attachment 6: a62f358e-b2c8-43b4-99c6-63047836c6ac.jpeg
a62f358e-b2c8-43b4-99c6-63047836c6ac.jpeg
Attachment 7: 423bd747-282b-45af-84ff-c639cdb9f5f0.jpeg
423bd747-282b-45af-84ff-c639cdb9f5f0.jpeg
  85   Mon Mar 3 05:17:20 2025 Sebastian, Denise, BenediktRunsScanbereich 257.175 nm - 257.675 nm
Zeit Scanbereich (nm) Anzahl Laserschritte Start LMD Stop LMD Messdauer (s) Elektronenkuehlung (s) Kommentar
5:16 Uhr 03.03.2025 257.175 - 257.2998 52 krypton0389 krypton0396 10 30 -
6:18 Uhr 03.03.2025 257.2998 - 257.4246 52 krypton0397 krypton0403 10 30 Ionen weg bei Laserstep 14 und 17 und 340
7:09 Uhr 03.03.2025 257.4246 - 257.5494 52 krypton0404 krypton0410 10 30 -
8:00 Uhr 03.03.2025 257.5494 - 257.6750 52 krypton0411 krypton0417 10 30 -
  88   Mon Mar 3 08:52:19 2025 Tamina, Rodolfo, Volker, Danyal, FlorianRunsExtended Scan 257.0574 nm - 257.8022 nm bei hoeherer Ionenenergie
Neue Umlauffrequenz: 1.78561578504741 MHz
rep freq laser : 3.57123157001
ecooler voltage: 157823 V

file 0418.lmd PMTs on ion distribution (laser blocked) and afterwards PMTs off and laser blocked
bunch is not centered enough between PD peaks


file 0419.lmd PMTs on ion distribution (laser blocked) and afterwards PMTs off and laser blocked
bunch is now properly centered enough between PD peaks (SW:56 bins,NW: 87)



Zeit Scanbereich (nm) Anzahl Laserschritte Start LMD Stop LMD Messdauer (s) Elektronenkuehlung (s) Kommentar
12:45 Uhr 03.03.2025 257.0574 - 257.1750 49 krypton0420 krypton0422 10 30 Run stopped due to missynchronization of laser and ion bunches
- - - - - - there was a typo in the laser repetition frequency (10th decimal place)
13:17 Uhr 03.03.2025 257.0574 - 257.1750 49 krypton0423 krypton0428 10 30 repeat of previous scan range
14:12 Uhr 03.03.2025 257.1750 - 257.2998 52 krypton0430 krypton0436 10 30 file 429 (14:07) closed, because of two fail injections in ESR
15:05 Uhr 03.03.2025 257.2998 - 257.4246 52 krypton0437 krypton0443 10 30 empty shot at step 34
em 16:24 Uhr 03.03.2025 257.4246 - 257.5494 52 krypton0444 krypton0450 10 30 -
17:16 Uhr 03.03.2025 257.5494 - 257.6742 52 krypton0451 krypton0452 10 30 Bad shots at 6, 8, empty shot at 9, 10; HF cavity gone -
17:38 Uhr 03.03.2025 257.5494 - 257.6742 52 krypton0453 krypton0459 10 30 -
18:37 Uhr 03.03.2025 257.6742 - 257.7990 52 krypton0460 krypton0466 10 30 -
  98   Tue Mar 4 01:05:33 2025 Sebastian, Benedikt, DeniseRunswhole range scan @2nd ion energy) without shift

Zeit Scanbereich (nm) Anzahl Laserschritte Start LMD Stop LMD Messdauer (s) Elektronenkuehlung (s) Kommentar
1:11 Uhr 04.03.2025 257.0502 - 257.175 52 krypton0509 krypton0515 10 30
2:04 Uhr 04.03.2025 257.175 - 257.2998 52 krypton0516 krypton0522 10 30
2:57 Uhr 04.03.2025 257.2998 - 257.4246 52 krypton0523 krypton0523 10 30 wurde abgebrochen nach etwa 10min wegen zu vielen leerschuessen
3:07 Uhr 04.03.2025 257.2998 - 257.4246 52 krypton0524 krypton0530 10 30 ab Laserstep 47 waren Ionen weg (dauerhaft), deswegem beginnt vorheriger Block ein paar Lasersteps frueher
4:26 Uhr 04.03.2025 257.4078 - 257.5494 59 krypton0532 krypton0539 10 30
5:25 Uhr 04.03.2025 257.5494 - 257.6742 52 krypton0540 krypton0546 10 30 bei Laserstep 28 waren Ionen (fast) weg
6:16 Uhr 04.03.2025 257.6742 - 257.7990 52 krypton0547 krypton0553 10 30



Laseruntergrund aufgenommen LMD krypton0531 da hier fuer ein paar min keine Ionen da waren


Interlock SIS18 und Unilac ab 3:50 Uhr sind reingegenagen und ab diesem Zeitpunkt hatten wir keinen Ionenstrahl mehr
Ionenstrahl war im ESR bis 4:20 Uhr nicht verfuegbar
  1   Fri Dec 13 13:39:05 2024 DanyalGeneralTest
Test
  4   Fri Jan 24 16:36:10 2025 RodolfoGeneralCameras
I have installed two cameras, which can be used to monitor the position of the laser beam. In order to access them (only at GSI) via a browser just type the "device's name" follow by "gsi.de"


Nomenclature Position Device Name
IRIS IN North-West Arc atpdev005.gsi.de
IRIS OUT South-West Arc apdev17.gsi.de


In both cases, the Benutzername is: admin and the Passwort: 1234
Attachment 1: Kamera_NW_ATPDEV005_IRIS-IN.PNG
Kamera_NW_ATPDEV005_IRIS-IN.PNG
Attachment 2: Kamera_SW_APDEV17_IRIS-OUT.PNG
Kamera_SW_APDEV17_IRIS-OUT.PNG
  6   Mon Jan 27 11:06:21 2025 SebastianGeneralOptiken ESR Lab, NW und SW eingebaut
Die Optiken (Layertec 2" und 3") ab TEM Spiegel ESR Lab 
bis ESR TEM Spiegel eingebaut.

5 grad Wedge vor Eintrittsfenster ESR.

1. Reflexion trifft auf TEM Keil für TEM PSDs
2. Reflexion trifft auf PH100

5 grad Wedge nach Austrittsfenster
  7   Mon Jan 27 16:55:46 2025 SebastianGeneralDLC Pro IP Adresse
SISDEV007
140.181.91.46
  10   Tue Jan 28 14:16:22 2025 SebastianGeneralShutter
Thorlabs Shutter SH1/M kann über STRPC001 (ESR Laserlab PC) und der Software SC10 genutzt werden.

COM 9 für Connection
Baud Rate 9600
  11   Tue Jan 28 15:57:05 2025 DeniseGeneralJustage: ESR Labor Periskop Spiegel oben
obere Schraube nach rechts drehen, dann bewegt sich Laserspot nach links 
selbe Schraube nach links dann Laser rechts

untere Schraube nach rechts drehen dann geht Laser nach unten 
selbe Schraube Laser nach oben 
  12   Wed Jan 29 10:23:21 2025 SebastianGeneralRemote Control Schirm Nord West Tower
Box zum rein und rausfahren hinter Laser PC im ESR

Zeiger von Rädchen muss auf "SCHIRM NW" stehen

Knopf oben betätigt den Schirm zum rein und rausfahren.


Zusätzlich gibt es im ESR am NW Tower einen Knopf zwischen Magnet und Tower, um den Schirm dort auch rein und rausfahren zu können.
  17   Thu Feb 6 11:03:26 2025 DanyalGeneralpressures in laser window sections NW and SW
The pressures, read by the UHV technician, are : 

E01VVLF1T (E01VMLF1X):           5.84e-10mbar
E02VVLF2T (E02VMLF2X):           2.91e-10mbar

In 2019 the pressures were sth like 2e-9 mbar. They are much lower now. 

Note: The valves LF1 and LF2 may only be opened after ESR extraction to HITRAP has been set up! 
Most likely this is Monday 10 Feb. 


The UHV technician is: 
Mr. Semjon Strohmenger 
Phone: +49 6159 71 1765 
PSA: 7651 
  19   Tue Feb 11 10:30:21 2025 DanyalGenerallaser valves are open
Die Laserventile im ESR sind nun offen. Der Laserstrahl darf durchgeschossen werden.

The "laser valves" (NW and SW) are now open.  The laser beam may pass through the ESR. 
  20   Tue Feb 11 10:32:01 2025 DanyalGeneralaccess to ESR
Es wird noch zwei 2 stündige Unterbrechungen am UNILAC geben. Wahrscheinlich diesen Freitag und nächste Woche Mittwoch oder Donnerstag. Am 25.2. wird dann die Gleitringdichtung der Pumpe am UNILAC gewechselt (8-18 Uhr) daher rechne ich mit Xe Strahl im ESR frühestes am 26.2.
Von HITRAP habe ich erfahren, dass wir Abends/Nachts was im Ring machen dürfen, ab 22 Uhr. z.B. am 17.2, 19.2 und 21.2.  Aber ich denke vorher (diese Woche) geht es bestimmt auch mal.

There will be two 2-hour breaks at the UNILAC. Probably this Friday and next week Wednesday or Thursday. On February 25th the mechanical seal of the pump on the UNILAC will be changed (8 a.m. to 6 p.m.) so I expect the Xe beam in the ESR on February 26th at the earliest.
I found out from HITRAP that we can do something in the ring in the evening/night, from 10 p.m. onwards. For example on February 17th, February 19th and February 21st.  But I think there will be some possibilities already this week. 