ID |
Date |
Author |
Category |
Subject |
41
|
Tue Apr 1 14:54:24 2025 |
all | General | No SIS beam since 14:35 |
|
40
|
Tue Apr 1 14:25:21 2025 |
ruijiu | Analysis | The frequency of 194Pb82+ has been changed from 408.606MHz to 408.602MHy during last 12 hours |
The following images display the frequency spectrum at the start of every hour from 3:00 to 14:00. |
39
|
Tue Apr 1 14:23:01 2025 |
JG | General | Pleiades pocket position tests |
We started playing with the detector pockets of the pleiades arrays at 14:23 01.04.2025.
This might disturb the beam sometimes.
The beam is lost in SIS at 14:35.
Beam came back at 16:40, we continued playing with pleiades positions until 17:14. |
38
|
Tue Apr 1 14:17:07 2025 |
Ruijiu | Analysis | PID of 194Pb82+ 2025.04.01.14.13.07 |
datafile = "/data.local/G22-00018_00203/results/analyzers/RSA01/RSA01-2025.04.01.14.13.07.068.tiq_spectrum.npz"
filep = "/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/rionid_exercises/exercise_194Pb_Exp_2025/New_TEline2022-ESR-194Pb-208Pb-nostripper_524MeV.lpp"
alphap = "1.399"
harmonics = "211"
refion = "194Pb+82"
circumference = "108.34"
mode = "Frequency"
value = "408602000"
reload_data = true
nions = "100" |
37
|
Tue Apr 1 14:02:23 2025 |
Jelena B, Siddharth | General | Lassie |
|
36
|
Tue Apr 1 12:58:27 2025 |
Jelena B, Siddharth | General | Lassie |
|
35
|
Tue Apr 1 11:47:14 2025 |
Jelena B, Siddharth | General | Lassie 2025-04-01_11-46-35-517_tcl1064.png |
|
34
|
Tue Apr 1 10:34:20 2025 |
Jelena B, Siddharth | General | Resolved issue with SIS18 |
Beam is back with some fluctuations.
We did not have beam from 9:34 until 10:08, around 35 minutes. |
33
|
Tue Apr 1 10:03:56 2025 |
Jelena B, Siddharth | General | Technical issue with SIS18 |
From HKR info: there is a technical issue with SIS18 and we will have no beam for next 25 minutes. |
32
|
Tue Apr 1 08:36:25 2025 |
Jelena B, Siddharth | General | Lassie 2025-04-01_08-37-32-155_tcl1064.png |
|
31
|
Tue Apr 1 06:53:51 2025 |
Jelena B,Siddharth | General | Lassie Monitor |
|
30
|
Tue Apr 1 06:31:46 2025 |
Michael | General | Lassie Monitor 2025-04-01_06-31-10-211_tcl1064.png |
|
29
|
Tue Apr 1 05:58:51 2025 |
Michael | General | Lassie Monitor 2025-04-01_05-58-09-122_tcl1064.png |
|
28
|
Tue Apr 1 05:29:45 2025 |
Michael | General | Lassie Monitor 2025-04-01_05-29-01-845_tcl1064.png |
|
27
|
Tue Apr 1 04:59:14 2025 |
Michael | General | Lassie Monitor 2025-04-01_04-58-31-351_tcl1064.png |
|
26
|
Tue Apr 1 04:27:10 2025 |
Michael | General | Lassie Monitor 2025-04-01_04-25-53-171_tcl1064.png |
|
25
|
Tue Apr 1 03:55:59 2025 |
Michael | General | Lassie Monitor 2025-04-01_03-55-21-183_tcl1064.png |
|
24
|
Tue Apr 1 03:52:56 2025 |
Shahab, Michael, Yue, Zac, Carlo | DAQ | good files |
all settings are done.
any files coming after this one is good:
RSA01-2025.04.01.03.52.59.247.tiq |
23
|
Tue Apr 1 03:50:12 2025 |
Shahab, Yue, Carlo, Zac, Esther, Michael | DAQ | Tuners of the both cavities set |
410 MHz cavity resonance frequency tuned. motors both on 50 mm
245 MHz cavity resonance frequency tuned. motors both on 390 mm |
22
|
Tue Apr 1 03:27:44 2025 |
Michael | General | Lassie Monitor 2025-04-01_03-22-05-395_tcl1064.png |
|