HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038 E0075 E0203_E0018
  masses & isomeres 2025, Page 9 of 17  Not logged in ELOG logo
ID Date Author Category Subject
  170   Fri Apr 4 21:21:25 2025 BJ MC ID KKGeneralLassie screenshots
  169   Fri Apr 4 20:48:25 2025 IDGeneralPocket moved
20:48: Inside pocket moved to 60mm and back to the outside position.
  168   Fri Apr 4 20:29:22 2025 KK BJ MCGeneralLassie screenshots
  167   Fri Apr 4 19:19:06 2025 BJ KK MCGeneralLassie screenshots
  166   Fri Apr 4 18:38:52 2025 Dima, Zac, Sid, Kanika, Ragan, Shahab, BeatrizDAQnew file name and settings for 245 MHz
new settings:
1.8 seconds recording on 245 MHz on RSA02

starting from file name:

2025.04.04.18.36.32.895


settings are in the attachment
  165   Fri Apr 4 18:24:31 2025 BJ KKGenerallassie screenshot
  164   Fri Apr 4 17:59:33 2025 Zac , SidDAQ17:58
DAQ stopped with last file in RSA1-2025.04.04.17.58.49.340.tiq

Now the plan is to change one of the analyzers to narrow band recording for longer from the 245 Schotkky. 
  163   Fri Apr 4 17:30:25 2025 siddharthAnalysisSigma vs Mean Freq. Plot for 188Hf72+ setting
  162   Fri Apr 4 17:13:12 2025 Team PleiadesDetectorsPLEIADES detector out
17:12 We moved the PLEIADES detector out, both are outside now (in parking position)
  161   Fri Apr 4 17:10:35 2025 H. Weick, S. LitvinovAcceleratorESR scraper setting
the new scraper setting for good isochronicity but still acceptable intensity losses is:
Done at ~ 15:00 today.
GEEXDS1HA (outside)          =  -8 mm
GEEXDS1HG (ToF-det-aperture) =  20.5 mm
GE01DS3HG                    = -84.2 mm  (fully open is -130 mm)
in addition, a detector pocket is in GE01DD2IG = 1.7 mm
  160   Fri Apr 4 17:04:39 2025 H. Weick, S. LitvinovAcceleratorslits after target, Bio_REM alarm
A Bio-REM detector on the roof of ESR caused an alarm and shut down the whole accelerator.
Too much primary beam going to ESR, noe we avoid it by catching the primary beam at TE4 slits.
The distribution on current grids looks liek in the LISE simulation, we cut at 5mm.
The beam come sin three charge states tehouter ones 82+, 81+ anyway do not make it to ESR, we need to cut also the 80+ at least half.
Then the dose rate on ESR roof is much lower 0.8 uSv/h -> 0.2 uSv/h.
  159   Fri Apr 4 16:59:25 2025 KK BJDAQLassie screen shots
  158   Fri Apr 4 16:24:48 2025 Ruijiu, YuriAnalysisPID of 186Hf
Code used to add up injection data.
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data/2025.04.04.13.00$ find /data.local/G22-00018_00203/results/analyzers/RSA01 -name "RSA01-2025.04.04.*.tiq_spectrogram.npz" > filelist.txt
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data/summed_spectrum$ python npz_addup.py --time-cut 0.14 filelist.txt
  157   Fri Apr 4 16:12:54 2025 JG, IDGeneralpleiades detectors moving
We started moving the pleiades detectors at 16:13 04-04-2025.

We have the inside pocket (GE01DD2IG) at 2mm. 
The outside pocket (GE01DD2AG) cannot be moved by the Device Control program, some problem with the tolerance (error message: outside of tolerance). Need to go in in a short break and check what is wrong.

We will partly scrape the beam.
  156   Fri Apr 4 16:12:14 2025 Team PLEIADESDetectorsInserting both PLEIADES detectors
We are inserting both PLEIADES detectors step-wise, one by one. Main beam should not be affected too long.
  155   Fri Apr 4 16:01:09 2025 ID, MC, KanikaGeneral186Hf running now + Lassie screenshots
Tuning is finished, 186Hf is running. Sharp peaks now.
  154   Fri Apr 4 14:47:29 2025 ID MG BJGeneralLassie screen shots
186Hf screen shots with better resolution
  153   Fri Apr 4 14:01:20 2025 MG, ID,NHGeneralScreen shot
Lassie screen shots 186Hf
  152   Fri Apr 4 11:48:37 2025 MG, NH, IDGeneralsetting change to 186Hf + Lassie screenshots
186Hf, 510MeV/u of 208Pb beam, ecooling not working 
  151   Fri Apr 4 11:44:31 2025 Ragan, Wolfram, Sergey, Zsolt, MagdaGeneral ESR setting change from 188Hf72+ to 186Hf72+
ESR setting is changed from 188Hf72+ to 186Hf72+. SIS-18 beam energy for 
this fragment is 510 MeV/u.Brho = 7.86166 Tm.
ELOG V3.1.5-fc6679b