HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038
  Bound beta decay experiment on Tl-205, Page 5 of 9  Not logged in ELOG logo
ID Date Author Category Subject Text Attachments
  84   Mon Mar 30 08:56:04 2020 TinoRunsSecond measurement with 206Pb81+ beam at I_cooler = 10 mA I_cooler = 10 mA

beam: 206Pb81+
  
  85   Mon Mar 30 09:26:37 2020 TinoRunsStopped Second measurement with 206Pb81+ beam at I_cooler = 10 mA Stopped Data recording for Restart of the
measurement
  
  86   Mon Mar 30 09:34:02 2020 TinoRunsRestart of second measurement with 206Pb81+ beam at I_cooler = 10 mA Stopped Data recording for Restart of the
measurement
  
  87   Mon Mar 30 10:01:31 2020 TinoRunsSecond measurement with 206Pb81+ beam at I_cooler = 10 mA

I_cooler = 10 mA
  
  88   Mon Mar 30 10:32:01 2020 TinoRunsSecond measurement with 206Pb81+ beam at I_cooler = 10 mA

I_cooler = 10 mA
  
  89   Mon Mar 30 10:57:43 2020 TinoRunsSecond measurement with 206Pb81+ beam at I_cooler = 10 mA

I_cooler = 10 mA
  
  90   Mon Mar 30 12:12:25 2020 ruijiuGeneralInstruction of NTCAP for shift personTo start a new run with NTCap, we need to
retart NTCAP. 
1. Stop labview program. 
 Instruction_of_NTCAP_for_shift_person.png 
  91   Mon Mar 30 12:16:04 2020 TinoRunsSecond measurement with 206Pb81+ beam at I_cooler = 10 mA

I_cooler = 10 mA
  
  92   Mon Mar 30 12:33:04 2020 TinoRunsSecond measurement with 206Pb81+ beam at I_cooler = 10 mA

I_cooler = 10 mA
  
  93   Mon Mar 30 13:02:49 2020 TinoRunsSecond measurement with 206Pb81+ beam at I_cooler = 10 mA

I_cooler = 10 mA
  
  94   Mon Mar 30 13:31:58 2020 TinoRunsSecond measurement with 206Pb81+ beam at I_cooler = 10 mA

I_cooler = 10 mA
  
  95   Mon Mar 30 13:40:57 2020 ruijiuDetectorsHV of Inner detector   IMG_20200330_133909.jpg 
  96   Mon Mar 30 13:41:20 2020 ruijiuDetectorsHV of Inner detector   IMG_20200330_133909.jpg 
  97   Mon Mar 30 14:02:41 2020 TinoRunsSecond measurement with 206Pb81+ beam at I_cooler = 10 mA

I_cooler = 10 mA
  
  98   Mon Mar 30 14:24:46 2020 ruijiuDAQstop taking data.1. stop run0272.lmd.
2. stop NTCAP. 
  NTCAp file:
  
  99   Mon Mar 30 14:48:02 2020 ruijiu and TinoDetectorsThe leakcurrent of SiPad is over the setting limit.Because the 
leakcurrent of 
6 Sipads is 
 Screenshot_20200330-145551.jpgScreenshot_20200330-145544.jpgIMG_20200330_144915.jpg 
  100   Mon Mar 30 15:03:58 2020 ruijiu Tino, Yuri, Lasoro, Nik and UliDetectorsthe gas bottle is empty.The gas bottle was empty. Tino replaced 
the previous old bottle with 50 bar gas left.
 IMG_20200330_152735_mh1585575780057.jpg 
  101   Mon Mar 30 16:25:05 2020 ruijiuDetectorsturn down the HVturn down the hv and pull out the detector.
 
  
  102   Mon Mar 30 16:37:53 2020 ruijiuAnalysis     
  103   Mon Mar 30 20:51:06 2020 RaganDetectorsBias Voltage for Si-padsThe limit of the leakage current for all Si
pads was increased from 1500 nA to 5000nA
and 
 Si_pad_bias-voltage.ods 
ELOG V3.1.5-fc6679b