HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018
  Bound beta decay experiment on Tl-205, Page 6 of 9  Not logged in ELOG logo
ID Date Author Categorydown Subject Text Attachments
  39   Sat Mar 28 15:23:05 2020 Alex, Ragan, Mei Bai Generalbeam lifetime measurementWe see two species in the Schottky spectra
during the beam lifetime measurement without
the target. The one (probably the primiary
 15854053877798703970476301545600.jpg 
  40   Sat Mar 28 16:09:50 2020 AlexGeneralno beam in the ESRRagan and Ruijiu went in the ESR for short
time to fix something with the slow control
of the silicon detector.
  
  42   Sat Mar 28 16:29:27 2020 Ragan, RuiJiu, EstherGeneralMalfunction of several ESR machinesThe HKR crew informs us that several machines
in ESR are showing malfunctions.
The on-call expert cannot be reached.
  
  43   Sat Mar 28 18:11:13 2020 Alex, YuriGeneralno beam in the ESRYuri and Sergey (on phone) have investigated
extensively the problem with having no beam
in the ESR. The FRS has been checked and
  
  49   Sun Mar 29 12:56:02 2020 Ragan, RuiJiuGeneralGood positive signals from MSCFAs we (RuiJiu and me) changed the jumpers
of MSCF 1, 2,3 and 4 yesterday, now we see
nice positive signals on picoscope.
 E1DF3452-4051-4EFF-ADC2-519389D0E60F.MOV 
  57   Sun Mar 29 20:32:20 2020 RaganGeneralTemplate for Pb halflive measurementbeam: 
energy: 
  
  61   Sun Mar 29 21:55:47 2020 RaganGeneralMWPCAlex goes to Messhute to check the signals
from MPWC. After he completes, we start with
the measurements with the primary beam )
 Comparison.png 
  65   Mon Mar 30 01:07:29 2020 RaganGeneralProblem with SIS runstop: 0256There is problem with SIS
Run stop: 0257.lmd (at1:06)
  
  67   Mon Mar 30 01:43:58 2020 RaganGeneralFirst measurement with 206Pb81+ beam pattern detailsThe following shows the pattern for first
measurement in ESR (gas jet is on for = 60*5
secs = 300 secs as it can be seen on step
 90FC7D41-6C97-4760-B5A3-3CF60643A405.jpegBF20DBD8-1672-4817-8412-13B29CBF2E0A.jpeg 
  74   Mon Mar 30 04:15:29 2020 RaganGeneralSecond measurement with 206Pb81+ beam at I_cooler = 200 mAIn the picture below, a very nice storage
of 206Pb81+ at 200 mA electron cooler current
for no gas jet target can be seen in ESR.
 1A7AE154-6A88-4AED-BA5D-748025FCD226.jpeg 
  79   Mon Mar 30 06:34:47 2020 RaganGeneral Second measurement with 206Pb81+ beam at I_cooler = 20 mA In the ESR picture below, the decay of beam
is very fast initially for few minutes and
then the decay is constant. But why does
 C7A2736D-9C0A-4531-A768-85A55943EB5A.jpeg 
  90   Mon Mar 30 12:12:25 2020 ruijiuGeneralInstruction of NTCAP for shift personTo start a new run with NTCap, we need to
retart NTCAP. 
1. Stop labview program. 
 Instruction_of_NTCAP_for_shift_person.png 
  107   Tue Mar 31 20:32:05 2020 RaganGeneral203Tl80+ 200Hg79+ 205Tl81+Below in the schottky spectrum, on left is
203Tl80+ contamination, in middel is 200Hg79+
contamination and on right most is 205Tl81+.
 85AD7203-736C-4531-BA80-D045CC690BED.jpeg 
  108   Tue Mar 31 20:50:05 2020 RaganGeneral200Hg79+ 205Tl81+203Tl80+ impurity is removed by moving scrapper
inside ESR.
Only 220Hg79+ is left now
 31E7D028-F469-4BFF-B683-203821C174E9.jpeg 
  109   Tue Mar 31 21:07:05 2020 RaganGeneralSeparation of 203Tl80+ and 200Hg79+ using scrapper in ESRIt can be seen in the video how 203Tl80+ (on
extreme left) and then 200Hg79+ (in middle
originally) is separted from 205Tl81+ by
 06B012F5-5435-41D7-AD82-4A5FDADF281E.MOV 
  113   Thu Apr 2 02:36:48 2020 RaganGeneralStochastic cooling and orbit problemOn 1 April by 5 pm, we could stop the stochastic
cooling after the stacking process and also
change the orbit of the Tl beam to centre.
  
  120   Thu Apr 2 12:52:25 2020 ruijiuGeneralsetup FRS with 2 g/cm2 degrader.Yuri sets up FRS with 2 g/cm2 degrader (previous
one is 1 g/cm2). The ESR is not changed.
The contamination should be less now.
  
  121   Thu Apr 2 15:24:15 2020 RaganGeneralHow to know whether electron cooling is workingFor Alle and Kuehler the bottom left status
should look like as shown in pictures below.
 IMG_8238.JPGIMG_8239.JPG 
  130   Fri Apr 3 04:36:21 2020 Ragan, Pierre-Michel, DimaGeneralElectron cooler problem which was then solved04:09 Electron cooler had some problem when
we were stacking for 2 hours measurement.
04:20 GECEBG2T and GECEBG5T were Reset and
  
  143   Sat Apr 4 03:06:12 2020 RaganGeneralInstructions if electron cooler goes off during long storage time measurementsPlease read the attachment.  electron_cooler.pdf 
ELOG V3.1.5-fc6679b