HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018
  Bound beta decay experiment on Tl-205, Page 8 of 9  Not logged in ELOG logo
ID Date Author Categorydown Subject Text Attachments
  101   Mon Mar 30 16:25:05 2020 ruijiuDetectorsturn down the HVturn down the hv and pull out the detector.
 
  
  103   Mon Mar 30 20:51:06 2020 RaganDetectorsBias Voltage for Si-padsThe limit of the leakage current for all Si
pads was increased from 1500 nA to 5000nA
and 
 Si_pad_bias-voltage.ods 
  111   Wed Apr 1 01:02:24 2020 ruijiuDetectorsthe detector cable is disconnected.    
  112   Wed Apr 1 01:05:36 2020 ruijiuDetectorsdetector position fixed at 60 mmThe detector cable was disconnected . We entered
and reconnected the cable.
 VID_20200401_010416.mp4 
  178   Thu Nov 19 09:14:40 2020 JanDetectorsremote MSCF settings for CsISiPHOSAttached is a list of all set values for the
5 MSCF shaper modules.
This was done prior to run0251, which served
 setting.1585477986det_mapping.png 
  180   Tue Dec 8 15:47:07 2020 JanDetectorsmanual preamp & shaper settings for CsISiPhosattached is a document showing fotos of all
involved amplifiers in the chain to document
the manual settings active during the experiment.
 amp_settings.pdf 
  2   Mon Dec 3 15:06:04 2018 Chen, SidhuDAQTest of two preamplifier.[B]Description:[/B]
   We have two pre-amplifiers:
   New: Max. range 5GeV, Two sensitivity
 20181121_ElectronicCircuits_1.png20181121_ElectronicCircuits_2.png20181121_ElectronicCircuits_3.png20181121_ElectronicCircuits_4.png 
  7   Tue Mar 12 12:54:58 2019 Chen, SidhuDAQhow to start DAQ and plot histogram.[B]1. login litv-exp account[/B]
rchen@lxg1254:/data.local2/2002_238UIMS$
ssh -X litv-exp@lxg0155.gsi.de
 000000000001_edit.png55_PM.pngdrawing-1.png 
  9   Tue May 28 08:36:14 2019 JanDAQMBS start & RFIO serverYou need a DAQ-PC and the RIO crate computer.
All of the DAQ proceedures laid out here
are operated from inside the DAQ screen session.
  
  10   Wed Jun 26 16:20:31 2019 JanDAQunpacker: lmd > rootI have written an unpacker for the lmd data
taken with the current daq-system for E121.
The crate configuration is as follows:
 E121.specdet_mapping.hh 
  15   Tue Feb 25 15:48:31 2020 ruijiu chenDAQImportant folders of e121 eperiments:1. slow control:
1.1. program file:
litv-exp@ringpi:~/epics/mrcc_ioc/db $ 
  
  16   Tue Feb 25 15:49:58 2020 ruijiu chenDAQchanging scaling factor.How to change scaling factor?
The parameters is in f_user.c file:
1. open the f_user.C with emacs :
  
  33   Sat Mar 28 12:19:21 2020 Ragan, RuiJiuDAQChange of the polarity of AmplifiersSince last night, the signals from the p-side
of all the Si pads were seen as negative
on picoscope.
 7888530B-DE66-4D37-A0A8-933307DD2AB8.MOV 
  37   Sat Mar 28 15:07:40 2020 ruijiuDAQstart run     
  41   Sat Mar 28 16:12:25 2020 ruijiu, raganDAQenter ESR and turn on the HV crate.    
  44   Sun Mar 29 09:40:35 2020 ruijiuDAQrestart go4go4 crush up. 
the problem is 
due to  mbs. 
 IMG_20200329_093354.jpg 
  51   Sun Mar 29 13:05:36 2020 ruijiuDAQstart ntcapIQ_2020-03-29_13-05-
56
SC_2020-03-29_13-05-
 IMG_20200329_130438.jpg 
  98   Mon Mar 30 14:24:46 2020 ruijiuDAQstop taking data.1. stop run0272.lmd.
2. stop NTCAP. 
  NTCAp file:
  
  175   Thu Oct 1 22:20:03 2020 JanDAQfinal unpacker configWe identified an issue with randomly missing
adc channels in all lmd-files before run
0273.
 E121.specdet_mapping.hh 
  176   Mon Nov 2 16:45:55 2020 JanDAQf_user & mbslogAttached is the f_user.c and the mbslog.l
files.
The readout function is for the following
 f_user.cmbslog.l 