ID |
Date |
Author |
Category |
Subject |
Text |
 |
107
|
Tue Mar 31 20:32:05 2020 |
Ragan | General | 203Tl80+ 200Hg79+ 205Tl81+ | Below in the schottky spectrum, on left is
203Tl80+ contamination, in middel is 200Hg79+
contamination and on right most is 205Tl81+.
|
|
108
|
Tue Mar 31 20:50:05 2020 |
Ragan | General | 200Hg79+ 205Tl81+ | 203Tl80+ impurity is removed by moving scrapper
inside ESR.
Only 220Hg79+ is left now |
|
109
|
Tue Mar 31 21:07:05 2020 |
Ragan | General | Separation of 203Tl80+ and 200Hg79+ using scrapper in ESR | It can be seen in the video how 203Tl80+ (on
extreme left) and then 200Hg79+ (in middle
originally) is separted from 205Tl81+ by |
|
113
|
Thu Apr 2 02:36:48 2020 |
Ragan | General | Stochastic cooling and orbit problem | On 1 April by 5 pm, we could stop the stochastic
cooling after the stacking process and also
change the orbit of the Tl beam to centre. |
|
117
|
Thu Apr 2 06:25:13 2020 |
Ragan | Runs | Template | beam: 205Tl81+ (no scraping)
energy: 400 MeV/u
storage time: ___ hrs
|
|
121
|
Thu Apr 2 15:24:15 2020 |
Ragan | General | How to know whether electron cooling is working | For Alle and Kuehler the bottom left status
should look like as shown in pictures below. |
 |
143
|
Sat Apr 4 03:06:12 2020 |
Ragan | General | Instructions if electron cooler goes off during long storage time measurements | Please read the attachment. |
|
169
|
Mon Apr 6 20:03:50 2020 |
Ragan | General | Experiment finished )) | E121 experiment is finished with the last
10 hours measurement at 19:47 ))
Many thanks to everyone for there significant |
|
170
|
Thu Apr 9 11:16:35 2020 |
Ragan | General | Measurements done in the experiment | |
  |
173
|
Mon Apr 20 11:17:18 2020 |
Ragan | General | Logbook | |
  |
183
|
Sun May 30 12:09:00 2021 |
Ragan | General | NTCAP | Attached is the info given by Carsten.
The instructions to operate NTCAP are given
on https://wiki.gsi.de/ESR_EXP/ManualOfNTCAP |
|
182
|
Mon Mar 29 16:31:09 2021 |
Pierre-Michel | DAQ | cross section | (1.393*^-8 + 3.18*^-13 + 4.707*^-8)/4.707*^-8
= 1.29595 |
|
34
|
Sat Mar 28 13:09:11 2020 |
Mei,Yury, Tino, Ragan, Ruijiu | General | Shift plan | From Yury,
For now, measure the beam life time with |
|
14
|
Fri Feb 21 11:30:52 2020 |
Laszlo | General | Shift plan | e127: https://docs.google.com/spreadsheets/d/14m8WcCq1erx6HqWJRK7TLbCx121IkjqGa5l-frf4YjI/edit#gid=0
e121: https://docs.google.com/spreadsheets/d/10MUzA5-Ilf2WzCyNj8u_KSG6yzPg0e4vtZGGPFB3K-k/edit#gid=0 |
|
1
|
Thu Sep 13 11:32:17 2018 |
Jan Glorius | Collaboration | Proposal | Attached is the beam time proposal submitted
and accepted by the G-PAC in 2017. |
 |
4
|
Fri Dec 7 10:56:04 2018 |
Jan Glorius | SlowControl | EPICS ioc on raspberry | We have an EPCIS server (ioc) running on our
raspberry (ext-027377). It talks to our MesyTec
modules (MSCF shapers, MHV4 high-voltages).
|
|
5
|
Fri Dec 7 11:39:41 2018 |
Jan Glorius | SlowControl | GUI for remote control of MSCF+MHV4 | We have a GUI for remote controlling our MesyTec
modules MSCF16 and MHV4 for E121 experiment.
|
|
9
|
Tue May 28 08:36:14 2019 |
Jan | DAQ | MBS start & RFIO server | You need a DAQ-PC and the RIO crate computer.
All of the DAQ proceedures laid out here
are operated from inside the DAQ screen session.
|
|
10
|
Wed Jun 26 16:20:31 2019 |
Jan | DAQ | unpacker: lmd > root | I have written an unpacker for the lmd data
taken with the current daq-system for E121.
The crate configuration is as follows:
|
 |
62
|
Sun Mar 29 23:48:12 2020 |
Jan | Analysis | run0251: E_spectra for CsISiPhos | This is a collection of energy spectra of
the CsISiPhos detectors from run0251 with
primary beam.
|
14x |