87
|
Fri Mar 20 19:37:43 2020 |
Jan | Calibration | Xray energies - rough 1. calibration | | -- E calibration seems to have changed! ---
This calibration is based on the source data |
|
270
|
Sun Apr 5 20:34:42 2020 |
Laszlo | Calibration | Xray energies - 1. calibration | | 30angle: E[keV] = 0.0158507 *ch-2.07456
90angle: E[keV] = 0.01950*ch-2.76
145angle: E[keV] = 0.017988 *ch-1.809
|
8x |
397
|
Sat May 22 21:33:22 2021 |
Laszlo | Detectors | Xray detectors are filled at 90 and 35 | 2021 | |
|
92
|
Sat Mar 21 01:25:07 2020 |
Laszlo | General | Vacuum while moving in the detector for fragment measurement | | Stayed below E-10
Start:2.42E-11
Top after moving: 4.144E-11 |
|
91
|
Fri Mar 20 23:43:26 2020 |
Laszlo | General | Vacuum while moving in the detector at yesterday evening | | Vacuum before DSSSD movement: 1.5844E-11
Top value after movement: 3.64378E-11
|
 |
183
|
Sun Mar 22 12:01:44 2020 |
Esther, Ragan | General | Vacuum problem with SIS | | There is some problem with the vacuum in SIS
and thus data recording is stopped. |
|
359
|
Thu May 20 18:13:55 2021 |
Laszlo | General | Vacuum change while Si movement | 2021 | The vacuum remained in the E-10 range after
moving the dsssd. The oscillation in the
vacuum.values are due to the
|
|
25
|
Wed Oct 23 14:51:43 2019 |
Jan, Laszlo | DAQ | VME modules & main.cfg | | Here is the current list of VME modules in
our DRASI daq including HW addresses:
|
|
574
|
Thu Jun 24 09:43:01 2021 |
Jan Glorius | DAQ | Unpacker | 2021 | The unpacker used for the production runs
of E127b is located at
/u/litv-exp/unpacker/unpackexps/e127_TO_2021_with_ECL
|
|
292
|
Wed Apr 28 09:12:47 2021 |
Jan, Yuri | Detectors | UI-diagram | 2021 | The UI-curve of the detector
U I
10 0.11
|
|
448
|
Tue May 25 15:56:48 2021 |
Robert/Shahab | Accelerator | Trafo | 2021 | Trafo was set to 0 |
|
358
|
Thu May 20 18:11:24 2021 |
Laszlo | General | Touching the beam with Dsssd - current change | 2021 | |
|
16
|
Mon Jul 8 14:57:07 2019 |
Yuanming Xing | Detectors | The measurement of the tilting angle | | As shown in the figure, the detector is tilted
by a certain angle which is about 45 degree.
|
|
284
|
Fri Oct 23 12:58:12 2020 |
Jan | Detectors | Test of 2nd DSSSD (gen2) | 2021 | This is the documentation of the source tests
with the 2nd micron DSSSD of 2nd generation
(label 3288-17, thickness 529um)
|
 |
285
|
Fri Nov 20 15:53:37 2020 |
Jan | Analysis | Test of 2nd DSSSD (gen2) | 2021 | Here is the analysis of the test runs with
the 2nd DSSD (gen2) using the quick_si_plots.c
script attached.
|
   |
571
|
Wed Jun 2 09:14:04 2021 |
Jan | General | Telegram Chat Export | 2021 | Attached is the exported Telegram chat.
There is the simple PDF and the zip-file
containing the chat in json-format as well |
 |
159
|
Sun Mar 22 01:36:14 2020 |
Pierre-Michel | Analysis | Target overlap | | Here are the data file for the rates of the
recoil detector for different values of the
target bump. The average rate over background |
10x |
89
|
Fri Mar 20 22:51:36 2020 |
Laszlo | General | Target on signal change | | From the previous settings:
JetOn
mashine number 11
|
  |
115
|
Sat Mar 21 10:20:27 2020 |
Ragan, Alex | General | Target LN2 | | The LN2 Dewar on the ESR roof has been refilled. |
|
67
|
Fri Mar 20 01:11:58 2020 |
Laszlo | General | Target - beam jntersection | | We have managed to find the target position
with the beam by looking at the xray spectra.
The trick was that at 10mev we
|
|