HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038
  proton-capture on 118Te, Page 16 of 29  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
IDdown Date Author Category Subject Year Text Attachments
  Draft   Tue Apr 21 22:25:00 2020 JanAnalysis      
  274   Wed Apr 8 23:02:24 2020 LaszloGenerallmd to measurement pairing list I use the following list of lmd files combined
to a single root file for each measurement.
It is very important to highlight that sometimes
 gas_jet_mailfunction.png 
  273   Wed Apr 8 20:06:10 2020 LaszloCalibrationCounts in the K-REC peaks 3 datasets were investigated:
-124Xe with Scraper    (2. Xray calibration
parameters needed)
 124Xe_wScraper_full_spectra_labels_thick.png124Xe_wScraper_90_backgnd.pngKREC-pics.zip 
  272   Mon Apr 6 23:00:51 2020 LaszloCalibrationbeam energies for 124Xe and 118Te measurements "The e- cooler settings were the same for
the 124Xe and 118Te beams" - Sergey --> speed
of the ions is the same --> same MeV/u
 SP54120040623030.pdf 
  271   Mon Apr 6 04:39:19 2020 LaszloCalibration2. Xray energy calibration 30angle:  E[keV] = 0.015898 *ch-1.91
90angle:  E[keV] = 0.0211075*ch-2.39
145angle: E[keV] = 0.01663  *ch-1.758
 9x 
  270   Sun Apr 5 20:34:42 2020 LaszloCalibrationXray energies - 1. calibration 30angle:  E[keV] = 0.0158507 *ch-2.07456
90angle:  E[keV] = 0.01950*ch-2.76
145angle: E[keV] = 0.017988  *ch-1.809
 8x 
  269   Thu Mar 26 12:05:22 2020 LaszloCalibrationmeasurement of collimators The measurements were taken by using a caliper
ruler, with precision of +/-0.05mm
 SP54120032612091.pdfSP54120032612090.pdf 
  268   Wed Mar 25 15:06:09 2020 LaszloAnalysisquick summary of the run numbers    SP54120032515060.pdf 
  267   Wed Mar 25 14:26:22 2020 LaszloCalibrationrun111 - Xray90 calib Am241, distance 167.5mm - LESS NOISE Detector: 90
Source: 241Am
Distance: 167.5mm
  
  266   Tue Mar 24 10:59:18 2020 JanCalibrationSources - Specifications We used the following sources:

[B]Am241[/B] (OM666) [GSI - Uwe]
 Pb-210-1.pdf241Am_Uwe.pdf133Ba_low.pdf133Ba_hi.pdf 
  265   Tue Mar 24 10:20:26 2020 LaszloCalibrationPictures of the xray calibration    IMG_20200324_101357.jpgIMG_20200324_101303.jpgIMG_20200324_101334.jpgIMG_20200324_100725.jpg 
  264   Tue Mar 24 00:11:35 2020 LaszloCalibrationrun116 - Xray35 calib AM241, distance 334mm Detector: 35
Source: 241Am
Distance: 334mm
  
  263   Mon Mar 23 22:25:41 2020 LaszloCalibrationrun115 - Xray35 Ba133 d=334mm, Xray90 Lead source, d=167.5mm Simultaneous measurement of Xray35 and Xray90.
The dead-time is <3%
  
  262   Mon Mar 23 21:47:40 2020 LaszloCalibrationrun114 - Xray145 calib Ba133, distance 305mm - LESS NOISE Detector: 145
Source: 133Ba - strong source
Distance: 305mm
  
  261   Mon Mar 23 20:52:37 2020 LaszloCalibrationrun113 - Xray145 calib Am241, distance 305mm - LESS NOISE Detector: 145
Source: 241Am
Distance: 305mm
  
  260   Mon Mar 23 19:32:53 2020 LaszloCalibrationrun112 - Xray90 calib Am241, distance 200mm - LESS NOISE Detector: 90
Source: 241Am
Distance: 200mm
  
  259   Mon Mar 23 18:17:27 2020 LaszloCalibrationrun110 - Xray90 calib Ba133, distance 167.5mm -low rate - LESS NOISE Detector: 90
Source: Ba133 - weak source
Distance: 167.5mm
  
  258   Mon Mar 23 18:15:55 2020 LaszloGeneralnoisy 90degree Xray det Uwe found out, that there was some common
ground effect between 90 and 145 degree detectors.
after moving the grounds, we could record
  
  257   Mon Mar 23 17:40:33 2020 LaszloCalibrationrun109 - Xray90 calib Ba133, distance 167.5mm -low rate Detector: 90
Source: Ba133 - weak source
Distance: 167.5mm
  
  256   Mon Mar 23 17:32:42 2020 LaszloCalibrationrun108 - Xray90 calib Ba133, distance 167.5mm - high rate - deadtime too high! Detector: 90
Source: Ba133 - strong source
Distance: 167.5mm
  
ELOG V3.1.5-fc6679b