299
Fri Apr 30 13:07:23 2021
Jan Glorius
Calibration
run0008 - Xray90 calib Pb210 d=167.5mm
2021
Efficiency calibration in the lab
Detector: GEM1800 - 90 deg
300
Fri Apr 30 13:10:44 2021
Jan Glorius
Calibration
run0007 - crap
2021
crap run
301
Fri Apr 30 13:56:59 2021
Jan Glorius
Calibration
run0009 - Xray90 calib Am241 d=167.5mm
2021
Efficiency calibration in the lab
Detector: GEM1800 - 90 deg
302
Fri Apr 30 14:35:11 2021
Jan Glorius
Calibration
run0010 - Xray90 calib Ba133 d=167.5mm
2021
Efficiency calibration in the lab
Detector: GEM1800 - 90 deg
303
Fri Apr 30 14:48:01 2021
Jan Glorius
Calibration
run0011 - Xray90 calib Ba133_low d=167.5mm
2021
Efficiency calibration in the lab
Detector: GEM1800 - 90 deg
304
Sat May 1 22:34:16 2021
Jan Glorius
Calibration
efficiency xray 90deg
2021
the attached efficiency curve for the 90 deg.
xray detector is made with the runs
e127b_run0008.lmd
305
Mon May 3 14:55:44 2021
Jan Glorius
Calibration
Xray energy calib. table
2021
Here is the table of energy calibration lines
from Am241 for all Xray detectors for several
measurements.
306
Tue May 4 14:31:51 2021
Jan Glorius
Calibration
run0012 - Xray35 calib Am241_hi d=334mm
2021
Efficiency calibration in the lab
Detector: GLP2000 - 35 deg
307
Tue May 4 14:34:51 2021
Jan Glorius
Detectors
Xray weight control induces signals
2021
When the readout/control of the det. weight
control via serial connection is active,
there is a clear signal induced in the Xray
308
Tue May 4 14:46:15 2021
Jan Glorius
Calibration
run0013 - Xray35 calib Am241_hi d=334mm
2021
Efficiency calibration in the lab
Detector: GLP2000 - 35 deg
309
Tue May 4 16:04:42 2021
Jan Glorius
Calibration
run0014 - Xray35 calib Am241_hi d=334mm
2021
Efficiency calibration in the lab
Detector: GLP2000 - 35 deg
310
Tue May 4 21:18:15 2021
Jan Glorius
Calibration
run0015 - Xray35 calib Am241_hi d=334mm
2021
Efficiency calibration in the lab
Detector: GLP2000 - 35 deg
311
Wed May 5 10:02:27 2021
Jan Glorius
Calibration
run0016 - Xray35 calib Ba133_hi d=334mm
2021
Efficiency calibration in the lab
Detector: GLP2000 - 35 deg
312
Wed May 5 14:24:57 2021
Jan Glorius
Calibration
run0018 - Xray35 calib Pb210 d=334mm
2021
Efficiency calibration in the lab
Detector: GLP2000 - 35 deg
313
Wed May 5 14:29:02 2021
Jan Glorius
Calibration
run0017 crap run
2021
314
Wed May 5 21:22:27 2021
Jan Glorius
Calibration
run0019 - Xray35 calib Pb210 d=334mm
2021
Efficiency calibration in the lab
Detector: GLP2000 - 35 deg
315
Thu May 6 09:40:37 2021
Jan Glorius
Calibration
run0020 - Xray35 calib Ba133_hi d=334mm
2021
Efficiency calibration in the lab
Detector: GLP2000 - 35 deg
316
Thu May 6 11:03:46 2021
Jan Glorius
DAQ
Cabling Documentation
2021
317
Thu May 6 13:39:02 2021
Jan Glorius
Calibration
efficiency xray 35deg
2021
the attached efficiency curve for the 35 deg.
xray detector is made with the runs
e127b_run0015.lmd
318
Thu May 6 14:30:35 2021
Jan Glorius
Calibration
run0021 - Xray35 calib Pb210 d=334mm
2021
Efficiency calibration in the lab
Detector: GLP2000 - 35 deg