127
|
Sat Mar 21 13:24:10 2020 |
Laszlo | Runs | run entry - run063 | |
open file : run063
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON, we had to stop becasue Ulli was noticing some strange effects with the target density. He needs now time to optimize that.
Detector position (Si): -24 mm
run start at 15:04 , first file: run063_0001.lmd
run stop at 15:04:21 , last file: run063_0xxx.lmd
_______________________________________________________________________________
time: 15:04 pm.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 2 Hz
Xray_90: 25 Hz
Xray_145: 30 Hz
BaF_OR: Hz
Si voltage: 60.02 V
Si leakage current: 4.10 uA
SIS particles before: ~2e9
ESR particles at injection: estimated ~1e6
ESR particles after decel.:
Target ON density: 1.52e13
copy and repeat the above (below the line) every 30 minutes |
128
|
Sat Mar 21 13:37:53 2020 |
Laszlo | | MCP can monitor target | |
now with the MCP we can see clearly the effect of the target :) (scintillation?)
so we want to scan through the target thickness with the beam and choose the best position afterwards.
We are making 3shoots for each bumb position (we change the bumb to make the intersection between beam and target) starting at ~14:
the data will be saved at the lxg1299 data.local2/hillenbrand/Laszlo folder |
129
|
Sat Mar 21 13:44:16 2020 |
Pierre-Michel | Detectors | Recoil detector | |
We turn on Recoil detector, to use it as a monitor for target overlap.
MCP front -2500 V for highest signal rate.
(Used to be -2250 V during previous beam time.)
DAQ triggered with 1 kHz clock in 2nd trigger input.
(2nd trigger used to be x-rays in previous beam time.)
The picture shows the increase of the Recoil rate when increasing the voltage from 2250 V to 2500 V in steps of 50 V. The last shot was taken without beam, so just target on. |
Attachment 1: Recoil.pdf
|
|
130
|
Sat Mar 21 14:52:05 2020 |
Laszlo | General | target optimization | |
previous position of the beam at target was -3mm (for the night position)
max. intensity position of the beam at target 1s -1mm. --> now it is set to this position
now Ulli also increasing the density of the jet. Right now Ulli is warming the noozle. --> takes 1hour roughly.
Earlier: 1.4E13
Now: |
Attachment 1: IMG_20200321_145105.jpg
|
|
Attachment 2: IMG_20200321_145059.jpg
|
|
132
|
Sat Mar 21 15:23:57 2020 |
Sergiy | Runs | run entry - run063 | |
open file : run063
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON, we had to stop becasue Ulli was noticing some strange effects with the target density. He needs now time to optimize that.
Detector position (Si): -24 mm
run start at 15:04 , first file: run063_0001.lmd
run stop at 15:04:21 , last file: run063_0xxx.lmd
_______________________________________________________________________________
time: 15:04 pm.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 2 Hz
Xray_90: 25 Hz
Xray_145: 30 Hz
BaF_OR: Hz
Si voltage: 60.02 V
Si leakage current: 4.10 uA
SIS particles before: ~2e9
ESR particles at injection: estimated ~1e6
ESR particles after decel.:
Target ON density: 1.52e13
copy and repeat the above (below the line) every 30 minutes |
133
|
Sat Mar 21 15:26:49 2020 |
Laszlo | General | SCRAPER is ON use again | |
Yuri puts back the scraper (Egelhof 1 - GE01DD1IG) into position = +19. (where it was in the evening) |
134
|
Sat Mar 21 15:30:34 2020 |
Sergiy | General | go into the ESR | |
We are going into the ESR to check the electronics.
Use calibration sources (133Ba etc). |
135
|
Sat Mar 21 17:21:57 2020 |
Laszlo | General | new Target density | |
Ulli and Nikos managed to set the target density to ~7E13 at 51K temperature
The cycle is checked again, it seems fine. |
136
|
Sat Mar 21 17:30:08 2020 |
Sergiy | Runs | run entry - run064 | |
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 17:30 , first file: run064_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 17:30 .
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 2-3 Hz
Xray_90: 29 Hz
Xray_145: 17 Hz
BaF_OR: Hz
Si voltage: 60.02 V
Si leakage current: 4.04 uA
SIS particles before: 2.5e9
ESR particles at injection: estimated ~1.3e6
ESR particles after decel.:
Target ON density: 1.34e13
copy and repeat the above (below the line) every 30 minutes |
137
|
Sat Mar 21 17:32:12 2020 |
Sergiy | Runs | run entry - run064 | |
open file : run064
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON. The target is back ON at 7e13.
Detector position (Si): -24 mm
run start at 17:30 , first file: run064_0001.lmd
run stop at 15:04:21 , last file: run064_0xxx.lmd
_______________________________________________________________________________
time: 17:30 pm.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 2 Hz
Xray_90: 25 Hz
Xray_145: 30 Hz
BaF_OR: Hz
Si voltage: 60.02 V
Si leakage current: 4.10 uA
SIS particles before: ~2e9
ESR particles at injection: estimated ~1e6
ESR particles after decel.:
Target ON density: 1.52e13
copy and repeat the above (below the line) every 30 minutes |
138
|
Sat Mar 21 17:34:10 2020 |
Sergiy | General | Recoils | |
We started recording the data from the recoils using the MCP from Pierre-Michael's experiment.
17:30 File opened: recoils1662.lmd.
data is stored at lxg1299: data.local2/hillenbrand/Laszlo |
140
|
Sat Mar 21 18:13:22 2020 |
Shahab | General | rough comparison gas target off and on | |
rough comparison of life time at 10 MeV/u when target off with on. more noise in background means weaker signal. |
Attachment 1: target_effect.jpg
|
|
139
|
Sat Mar 21 18:13:22 2020 |
Sergiy | Runs | run entry - run064 | |
open file : run064
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON and SCRAPER is back again--> We expect to cut the Rutherford for now on.
Detector position (Si): -24 mm
run start at 17:42 , first file: run064_0001.lmd
run stop at , last file: run064_0xxx.lmd
_______________________________________________________________________________
time: 18:12 pm.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 1 Hz
Xray_90: 35 Hz
Xray_145: 14 Hz
BaF_OR: Hz
Si voltage: 60.02 V
Si leakage current: 4.10 uA
SIS particles before: ~3.1e9
ESR particles at injection: n.n.
ESR particles after decel.:
Target ON density: 7e13
copy and repeat the above (below the line) every 30 minutes |
141
|
Sat Mar 21 18:42:43 2020 |
Sergiy | Runs | run entry - run065 | |
open file : run065
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON and SCRAPER is back again--> We expect to cut the Rutherford for now on.
Detector position (Si): -24 mm
run start at 18:42 , first file: run065_0001.lmd
run stop at , last file: run064_0xxx.lmd
_______________________________________________________________________________
time: 18:42 pm.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 3 Hz
Xray_90: 30 Hz
Xray_145: 15 Hz
BaF_OR: Hz
Si voltage: 60.02 V
Si leakage current: 4.08 uA
SIS particles before: ~3.1e9
ESR particles at injection: n.n.
ESR particles after decel.:
Target ON density: 6.8e13
copy and repeat the above (below the line) every 30 minutes |
142
|
Sat Mar 21 19:11:33 2020 |
Sergiy | Runs | run entry - run065 | |
open file : run065
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON and SCRAPER is back again--> We expect to cut the Rutherford for now on.
Detector position (Si): -24 mm
run start at 18:42 , first file: run065_0001.lmd
run stop at 19:42 , last file: run064_0xxx.lmd
_______________________________________________________________________________
time: 19:12 pm.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 5 Hz
Xray_90: 22 Hz
Xray_145: 22 Hz
BaF_OR: Hz
Si voltage: 60.02 V
Si leakage current: 4.08 uA
SIS particles before: ~2.6e9
ESR particles at injection: n.n.
ESR particles after decel.:
Target ON density: 6.9e13
copy and repeat the above (below the line) every 30 minutes |
143
|
Sat Mar 21 19:42:33 2020 |
Sergiy | Runs | run entry - run066 | |
open file : run066
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON and SCRAPER is back again--> We expect to cut the Rutherford for now on.
Detector position (Si): -24 mm
run start at 19:42 , first file: run066_0001.lmd
run stop at , last file: run065_0xxx.lmd
_______________________________________________________________________________
time: 19:42 pm.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 2 Hz
Xray_90: 27 Hz
Xray_145: 19 Hz
BaF_OR: Hz
Si voltage: 60.02 V
Si leakage current: 4.07 uA
SIS particles before: ~3.1e9
ESR particles at injection: n.n.
ESR particles after decel.:
Target ON density: 6.9e13
copy and repeat the above (below the line) every 30 minutes |
144
|
Sat Mar 21 20:11:59 2020 |
Sergiy | Runs | run entry - run066 | |
open file : run066
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON and SCRAPER is back again--> We expect to cut the Rutherford for now on.
Detector position (Si): -24 mm
run start at 19:42 , first file: run066_0001.lmd
run stop at , last file: run065_0xxx.lmd
_______________________________________________________________________________
time: 20:12 pm.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 4 Hz
Xray_90: 28 Hz
Xray_145: 14 Hz
BaF_OR: Hz
Si voltage: 60.01 V
Si leakage current: 4.08 uA
SIS particles before: ~2.9e9
ESR particles at injection: n.n.
ESR particles after decel.:
Target ON density: 6.5e13
copy and repeat the above (below the line) every 30 minutes |
145
|
Sat Mar 21 20:39:38 2020 |
Sergiy,Ruijiu | Runs | run entry - run067 | |
open file : run067
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON and SCRAPER is back again--> We expect to cut the Rutherford for now on.
Detector position (Si): -24 mm
run start at 20:41 , first file: run067_0001.lmd
run stop at 20:39 , last file: run066_0xxx.lmd
_______________________________________________________________________________
time: 20:41 pm.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 2 Hz
Xray_90: 43 Hz
Xray_145: 35 Hz
BaF_OR: Hz
Si voltage: 60.01 V
Si leakage current: 4.08 uA
SIS particles before: ~2.9e9
ESR particles at injection: n.n.
ESR particles after decel.:
Target ON density: 6.43e13
copy and repeat the above (below the line) every 30 minutes |
146
|
Sat Mar 21 21:11:46 2020 |
Sergiy,Ruijiu | Runs | run entry - run067 | |
open file : run067
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON and SCRAPER is back again--> We expect to cut the Rutherford for now on.
Detector position (Si): -24 mm
run start at 20:41 , first file: run067_0001.lmd
run stop at 20:39 , last file: run066_0xxx.lmd
_______________________________________________________________________________
time: 21:12 pm.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 4 Hz
Xray_90: 29 Hz
Xray_145: 25 Hz
BaF_OR: Hz
Si voltage: 60.01 V
Si leakage current: 4.08 uA
SIS particles before: ~2.5e9
ESR particles at injection: n.n.
ESR particles after decel.:
Target ON density: 6.e13
copy and repeat the above (below the line) every 30 minutes |
147
|
Sat Mar 21 21:36:06 2020 |
Jan | Runs | target incident | |
in run 66 or 67 we had a single ESR cycle for which the target didn't switch off for new injection and deceleration etc.
Very likely the DAQ also didn't get an OFF signal and collected OFF data to the TRIGGER=1 (ON data) branch.
As a consequence we collected about ~100 counts on the Si in one shot, which was about ~20 counts before this shot.
attached:
1.picture of the target density and beam current at this time. |
Attachment 1: run67_target_incident.png
|
|