HOME
ESR
EXPERIMENTS
LABS etc
E121
E127
E132
E125
E143
laser_cooling_2021
E142
Ê128
E146
E0052
E0018
E0028
proton-capture on 118Te, Page 22 of 29
Not logged in
Find
|
Login
|
Help
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Category --
Analysis
Calibration
DAQ
General
Collaboration
Runs
Detectors
Simulations
Accelerator
572 Entries
Goto page
Previous
1
,
2
,
3
...
21
, 22,
23
...
27
,
28
,
29
Next
ID
Date
Author
Category
Subject
Year
Text
127
Sat Mar 21 13:24:10 2020
Laszlo
Runs
run entry - run063
open file : run063
beam: 118Te52+
128
Sat Mar 21 13:37:53 2020
Laszlo
MCP can monitor target
now with the MCP we can see clearly the effect
of the target :) (scintillation?)
so we want to scan through the target thickness
129
Sat Mar 21 13:44:16 2020
Pierre-Michel
Detectors
Recoil detector
We turn on Recoil detector, to use it as a
monitor for target overlap.
130
Sat Mar 21 14:52:05 2020
Laszlo
General
target optimization
previous position of the beam at target was
-3mm (for the night position)
max. intensity position of the beam at target
132
Sat Mar 21 15:23:57 2020
Sergiy
Runs
run entry - run063
open file : run063
beam: 118Te52+
133
Sat Mar 21 15:26:49 2020
Laszlo
General
SCRAPER is ON use again
Yuri puts back the scraper (Egelhof 1 - GE01DD1IG)
into position = +19. (where it was in the
evening)
134
Sat Mar 21 15:30:34 2020
Sergiy
General
go into the ESR
We are going into the ESR to check the electronics.
Use calibration sources (133Ba etc).
135
Sat Mar 21 17:21:57 2020
Laszlo
General
new Target density
Ulli and Nikos managed to set the target density
to ~7E13 at 51K temperature
136
Sat Mar 21 17:30:08 2020
Sergiy
Runs
run entry - run064
beam: 118Te52+
energy: 10 MeV/u
137
Sat Mar 21 17:32:12 2020
Sergiy
Runs
run entry - run064
open file : run064
beam: 118Te52+
138
Sat Mar 21 17:34:10 2020
Sergiy
General
Recoils
We started recording the data from the recoils
using the MCP from Pierre-Michael's experiment.
140
Sat Mar 21 18:13:22 2020
Shahab
General
rough comparison gas target off and on
rough comparison of life time at 10 MeV/u
when target off with on. more noise in background
means weaker signal.
139
Sat Mar 21 18:13:22 2020
Sergiy
Runs
run entry - run064
open file : run064
beam: 118Te52+
141
Sat Mar 21 18:42:43 2020
Sergiy
Runs
run entry - run065
open file : run065
beam: 118Te52+
142
Sat Mar 21 19:11:33 2020
Sergiy
Runs
run entry - run065
open file : run065
beam: 118Te52+
143
Sat Mar 21 19:42:33 2020
Sergiy
Runs
run entry - run066
open file : run066
beam: 118Te52+
144
Sat Mar 21 20:11:59 2020
Sergiy
Runs
run entry - run066
open file : run066
beam: 118Te52+
145
Sat Mar 21 20:39:38 2020
Sergiy,Ruijiu
Runs
run entry - run067
open file : run067
beam: 118Te52+
146
Sat Mar 21 21:11:46 2020
Sergiy,Ruijiu
Runs
run entry - run067
open file : run067
beam: 118Te52+
147
Sat Mar 21 21:36:06 2020
Jan
Runs
target incident
in run 66 or 67 we had a single ESR cycle
for which the target didn't switch off for
new injection and deceleration etc.
Goto page
Previous
1
,
2
,
3
...
21
, 22,
23
...
27
,
28
,
29
Next
ELOG V3.1.5-fc6679b