93
Sat Mar 21 01:44:57 2020
Laszlo
General
from the SIS side they could optimize the
intensity. we gained a factor ~3. Now the
SIS intensity is at
92
Sat Mar 21 01:25:07 2020
Laszlo
General
Vacuum while moving in the detector for fragment measurement
Stayed below E-10
Start:2.42E-11
Top after moving: 4.144E-11
91
Fri Mar 20 23:43:26 2020
Laszlo
General
Vacuum while moving in the detector at yesterday evening
Vacuum before DSSSD movement: 1.5844E-11
Top value after movement: 3.64378E-11
90
Fri Mar 20 22:54:30 2020
Laszlo
General
First view of the beam
Intensity from Sis 1.7E9
The intensity is too.low at ESR to be visible.
However we could.catch it somehow with Shottky
89
Fri Mar 20 22:51:36 2020
Laszlo
General
Target on signal change
From the previous settings:
JetOn
mashine number 11
88
Fri Mar 20 22:26:42 2020
Jan
Detectors
BaF2 deactivated
BaF2 detectors are deactivated nor for the
following runs.
87
Fri Mar 20 19:37:43 2020
Jan
Calibration
Xray energies - rough 1. calibration
-- E calibration seems to have changed! ---
This calibration is based on the source data
86
Fri Mar 20 16:58:02 2020
Jan
DAQ
Xray2 & Xray3 cabling
We found that Xray2 and Xray3 the cabling
is not consistent:
85
Fri Mar 20 16:54:53 2020
Jan
DAQ
BaF OFF downscaled red=32
I introduced a downscaling by a factor of
2^5=32 for the BaF2 during target OFF.
The reason is, that we get a lot reasonable
84
Fri Mar 20 16:48:00 2020
Laszlo
General
flipped Si shaper output in x and y
Yesterday evening we have found out that the
energy signals from the silicon are negative
--> wrong polarity of the shapers was chosen
83
Fri Mar 20 13:21:33 2020
Jan, Laszlo
Analysis
124Xe data of first night
The unpacked data of all runs from the first
night (46-50) is located at
litv-exp@lxg0188:/data.local2/E127_lmd/124Xe_1st_night.root
82
Fri Mar 20 11:00:25 2020
Ragan, RuiJiu
Runs
run entry - run050
Yuri and ESR team are optimising
the deceleration in ESR.
DSSSD detector is taken out at
81
Fri Mar 20 10:28:31 2020
Ragan, RuiJiu
Runs
run entry - run050
Beam is back at 10:27 am.
Open file: runstart050
80
Fri Mar 20 08:30:52 2020
Ragan, RuiJiu
Runs
run entry - run049
There is no beam due to water leakage in the
transfer channel of SIS.
79
Fri Mar 20 08:01:40 2020
Ragan, RuiJiu
Runs
run entry - run049
beam: 124Xe54+
energy: 10 MeV/u
78
Fri Mar 20 07:30:16 2020
Ragan, RuiJiu
Runs
run entry - run049
beam: 124Xe54+
energy: 10 MeV/u
77
Fri Mar 20 07:01:06 2020
Shahab
Runs
run entry - run048
beam: 124Xe54+
energy: 10 MeV/u
76
Fri Mar 20 06:34:40 2020
Shahab
Runs
run entry - run048
beam: 124Xe54+
energy: 10 MeV/u
75
Fri Mar 20 06:00:26 2020
Shahab
Runs
run entry - run047
beam: 124Xe54+
energy: 10 MeV/u
74
Fri Mar 20 05:32:44 2020
Shahab
Runs
run entry - run047
beam: 124Xe54+
energy: 10 MeV/u