ID |
Date |
Author |
Category |
Subject |
Year |
Text |
|
52
|
Sun Mar 15 18:09:19 2020 |
Laszlo | Calibration | run039 - Xray90 calib Ba133 | | Detector: 90
Source: Ba133
Distance: 167.5mm
|
|
51
|
Sun Mar 15 17:50:42 2020 |
Laszlo | Calibration | run038 - Xray90 calib Ba133, high rate | | Detector: 90
Source: Ba133 - high rate
Distance: 167.5mm
|
|
50
|
Sun Mar 15 17:33:17 2020 |
Laszlo | Calibration | run037 - Xray90 calib Am241 | | Detector: 90
Source: Am241
Distance: 167.5mm
|
|
49
|
Sun Mar 15 17:14:08 2020 |
Laszlo | Calibration | run036 - Xray90 calib Am241, distance 200! | | Detector: 90
Source: Am241
Distance: 200mm
|
|
48
|
Sun Mar 15 17:13:21 2020 |
Laszlo, Jan | Calibration | the x-ray gate issue | | We found a strange behaviour of our ADC gates
for the x-ray detectors.
The setting as shown in the foto below corresponds |
|
47
|
Sun Mar 15 17:12:40 2020 |
Laszlo, Jan | Detectors | new Ortec spec amps | | We are now using new SpecAmps for the x-ray
detectors from ORTEC, they deliver much improved
resolution but have other strange effects |
|
46
|
Sun Mar 15 15:08:44 2020 |
Jan | Calibration | run035 - Xray145 calib B133 high rate | | measurement with old tennelec specAmps, do
not use for efficiency!
|
|
45
|
Sun Mar 15 14:41:34 2020 |
Jan | Calibration | run034 - Xray145 calib B133 high rate -SOURCE MOVED! | | measurement with old tennelec specAmps, do
not use for efficiency!
|
|
44
|
Sun Mar 15 13:52:05 2020 |
Jan | Calibration | run033 - Xray145 calib Am241 | | measurement with old tennelec specAmps, do
not use for efficiency!
|
|
43
|
Sun Mar 15 13:40:11 2020 |
Jan | Calibration | run032 - Xray90 calib Ba133 | | measurement with old tennelec specAmps, do
not use for efficiency!
|
|
42
|
Sun Mar 15 13:08:38 2020 |
Jan | Calibration | run031 - Xray90 calib Ba133 hi-rate | | measurement with old tennelec specAmps, do
not use for efficiency!
|
|
41
|
Sun Mar 15 09:42:40 2020 |
Jan | Calibration | run030 - Xray90 calib Am241 | | measurement with old tennelec specAmps, do
not use for efficiency!
|
|
40
|
Wed Mar 11 14:33:44 2020 |
Laszlo | General | beam time manual | | Here you can find the digital version of the
E127 beam time manual. |
|
39
|
Wed Mar 11 09:08:21 2020 |
Jan | DAQ | DAQ & controls - OVERVIEW | | For all DAQ & slow control buissines the user
[COLOR=red][SIZE=3]litv-exp[/SIZE][/COLOR]
|
|
38
|
Tue Mar 10 09:41:26 2020 |
Jan | Detectors | x-ray background from BaF | | The BaF2 detectors planned to be installed
at the target induce an additional background
in the x-ray detectors sitting below inside |
|
37
|
Tue Mar 10 08:52:34 2020 |
Jan | Detectors | DSSSD positioning | | To find a good Si position, we need to follow
a procedure similar to this:
|
|
36
|
Fri Feb 21 11:29:59 2020 |
Jan | Detectors | det. distances at target chamber | | This is the lookup table for the distance
of each x-ray detector to the target.
See attched foto for explanation.
|
|
35
|
Fri Feb 21 11:29:02 2020 |
Laszlo | General | Shift plan | | https://docs.google.com/spreadsheets/d/14m8WcCq1erx6HqWJRK7TLbCx121IkjqGa5l-frf4YjI/edit#gid=0 |
|
34
|
Fri Feb 21 09:39:40 2020 |
Laszlo | DAQ | cable documentation | | |
|
33
|
Mon Feb 17 08:14:44 2020 |
Jan | Simulations | 118Te K-REC X-ray energies | | X-ray energies of K-REC for 118Te according
to
[URL=http://www-ap.gsi.de/Thomas/ap_html_research/energy/index.php]http://www-ap.gsi.de/Thomas/ap_html_research/energy/index.php[/URL]
|
|