205
|
Mon Apr 11 07:54:37 2022 |
Danyal, Alexandre, Kristian, Sebastian | Accelerator | Jump in E-cooler voltage |
We saw a jump in the E-cooler voltage at about 7:50.
jump from 209619 to 209610 V
At 7:56 it jumped back to 209619 V
seems stable now |
93
|
Tue Apr 5 09:39:01 2022 |
Danyal & Yuri | Accelerator | Strahl ist wieder im ESR - Schlitz war reingefahren |
Der Strahl ist wieder im ESR!
Angeblich war einen Schlitz, oder sogar 2, reingefahren worden.
Es könnte entweder der GEEXDR11S und/oder den GEEXDR1AS gewesen sein.
Wir haben jetzt folgende Parameter:
SIS Injektionsenergie = 537.5 MeV/u (haben wir nicht geändert)
Chopper window 70 us (nicht geändert)
Wir haben jetzt etwa 1.2e9 Ionen pro Injektion im ESR |
94
|
Tue Apr 5 09:45:47 2022 |
Danyal & Yuri | Accelerator | beam is back in the ESR - a slit was moved in |
And now also in English :)
The ion beam is back in the ESR!
Apparently, there was a slit moved in. (Maybe even 2)
This could have been GEEXDR11S and/or the GEEXDR1AS
We now have the following parameters:
SIS injection energy = 537.5 MeV/u (we did not change this)
Chopper window 70 us (we did not change this)
We now have about 1.2e9 ions per injection in the ESR |
165
|
Fri Apr 8 14:46:02 2022 |
Danyal & Sebastian & Volker & Ken | Detectors | high dark countrate Cu PMT solved |
The problem - "discovered" by Volker and Ken - of the high dark countrate of the Cu PMT has been solved.
(when the Cu mirror was moved in, the dark countrate was very high ... also without ion beam)
I asked Graziano Savino to check the vacuum gauges along the target side of the ESR (west side).
The gauges at the laser window sections (which we do not use here!) - NW and SW - were still on.
Volker remembered that, in the past, for the lowest dark countrate at the Cu PMT --> ALL GAUGES MUST BE SWITCHED OFF.
Graziano turned them off and Sebastian and I checked the Cu PMT rate in DAQ1.
Attached you can clearly see the difference: from 7500 cps to 400 cps.
When the Cu mirror is retracted the dark countrate is 200 cps.
Danyal
PS The slow increase in one plot is due to the fact that Graziano switched on the light in the ESR. |
140
|
Thu Apr 7 15:18:25 2022 |
Danyal & Sebastian | DAQ | DAQ channels |
We checked again the cables for both DAQs
(on Carsten's kind request)
Channels for both DAQs are:
0 XUV-Back
1 XUV-Anode
2 XUV-Anode-delayed
3 PMT-South (new PMT, new threshold)
4 PMT-Middle
5 PMT-North
6 PMT-Cu
7 Part-det-south
8 Part-det-north
9 -
10 -
11 -
12 -
13 PD-NO
14 PD-SO
15 Q-switch |
106
|
Wed Apr 6 08:31:54 2022 |
Danyal & Regina | General | ESR had some errors |
Regina noticed that the ESR was "red"
This means that there are some errors.
She found:
correction fields in the dipoles were off
GE01KP02 ... 05
GE01KP22 ... 24
and some correction elements were off
GE02KX6
GE01KX2
Regina would like to know since WHEN this is the case.
In general, such errors affect the ion beam trajectory !
Regina will try to find out more details on how this may have shifted the orbit. |
113
|
Wed Apr 6 18:51:33 2022 |
Danyal & Carsten | Accelerator | target bump |
This afternoon, we found out that Sergey has also implemented a "target bump".
Although we do not use a target, this bump is still convenient because
we can move the ion beam such that is passes perfectly through the Cu mirror.
The setting is -8 mm and 1.3 mrad (if I am not mistaken)
We tested the effect on the position of the ion beam using the
horizontal scrapers at the target: GEEXDS1HA and GEEXDS2HA.
With the target bump set to "zero" (0 mm and 0 mrad),
the ion beam passed 6-8 mm to the outside.
This way, it will e.g. not pass centrally through the slit in the Cu mirror.
With the target bump set to -8 mm and 1.3 mrad, which is the default setting, the ion beam passed centrally.
Therefore, we left the target bump like this. |
105
|
Wed Apr 6 08:06:02 2022 |
Danyal | DAQ | stopped NTCAP data acquisition |
I stopped the NTCAP data acquisition at 8 AM.
Let's hope that the file contains good data. |
107
|
Wed Apr 6 09:30:53 2022 |
Danyal | Accelerator | ESR is blue again - errors are fixed |
The ESR is "blue" again.
The errors (scu related) have been fixed.
In principle, normal operation should be possible.
After the morning meeting Regina will return to the main control room.
I guess that we continue at 10 AM. |
139
|
Thu Apr 7 14:13:27 2022 |
Danyal | Detectors | new PMT south |
I have replaced the PMT south (looks at the gas target).
in the hope that this will produce less dark counts.
Thus far, the dark countrate is low (few Hz).
brand: ET enterprises
type: 2" photomultiplier, 9423B
High voltage: -2.45 kV (up to -3.5 kV)
spectral range: 110 - 230 nm
The power comes from an additional 2.5 kV supply.
(I have changed the cable: was CH0 before) |
206
|
Mon Apr 11 10:17:01 2022 |
Danyal | Accelerator | Interlock - reset |
10:17
Wie heutemorgen in der Sitzung (morning briefing) vereinbart,
führt Herr Florenkowski einen Interlock und danach einen Reset von E02MK durch.
Das dauert nur ca. 15 min.
nach dem interlock wurde der ESR "rot"
Um 10:21 war das problem gelöst und der ESR war wieder "blau" |
159
|
Fri Apr 8 11:02:04 2022 |
DW, YL, RSS, SL | | Change h=2 to h=1 |
After changing to h=1
The frequency manipulation #5: f=242.021487MHz (124th harmonic) [no bunching]
Manipulation #7: f=242.021812 MHz [with bunching] |
201
|
Sun Apr 10 15:29:37 2022 |
Carsten,Sarper | Accelerator | Ecooler failed |
Ecooler failed @15:23 Carsten is fixing it
Fixed @16:00 |
185
|
Sat Apr 9 15:47:21 2022 |
Carsten, Rodolfo, Sarper, Patrick | Runs | Afternoon and night shift runs |
After the morning shift, we got new increment (nm) for the laser scanning. We are now scanning 2 nm of wavelength range in 5 big steps (5 x 0.4 nm). Started with 323.2 nm - 322.8 nm range. Every big step (0.4 nm) is scanned with 0.002 nm of wavelength increment.
Every scan takes ~ 18 min (0.4 nm range with 0.002 nm steps), we have scanned 2 loops. Total scanning time ~36 min.
DAQ1: lxg1927:/data.local2/BeamTimeTh22/
DAQ2: lxg0155:/data.local2/E142/
LMD file name DAQ1:229Thor
LMD file name DAQ2:229Th
Schottky marker pos: 243.973MHz
Time | SIS-intensity | cooler-HV | LMD-DAQ1 start-end | LMD-DAQ2 start-end | scan range(nm) | step width(nm) | dwell time(s) | comments
|
xx:xx | x.xe9 | 209xxx | 0xxx | 78xx | 32x.x - 32x.x | 0.002 | x | sketch for filling the table
|
15:14 | 1.5e9 | 209624 | 0111-0111 | 7847-7847 | 323.2 - 322.8 | 0.002 | 5s | DAQ 2 no VUPROM TDC Pat south
|
xx:xx | 1.5e9 | 209624 | 0111-0111 | 7847-7847 | 323.2 - 322.8 | 0.002 | 5s | DAQ 2 changed TDC part south from ch 8 to ch 10
|
17:05 | 2.2e9 | 209624 | 0113-0113 | 7848-7848 | 323.2 - 322.8 | 0.002 | 5s | successful scan
|
19:04 | 1.8e9 | 209616 | 0116-0116 | 7850-7850 | 323.2 - 322.8 | 0.002 | 5s | Intensity optimization, see below, DAQ 2 TDC part south back to channel 8 - ok, XUV detector and Cu mirror moved correctly, lost the laser beam after the half of the second loop
|
19:49 | 1.8e9 | 209614 | 0117-0117 | 7851-7851 | 323.2 - 322.8 | 0.002 | 5s | successful scan
|
20:28 | 2.0e9 | 209622 | 0118-0118 | 7852-7852 | 323.2 - 322.8 | 0.002 | 5s | successful scan
|
21:07 | 2.2e9 | 209623 | 0119-119 | 7853-7853 | 323.2 - 322.8 | 0.002 | 5s | successful scan
|
22:01 | 1.8e9 | 209621 | 0122-0122 | 7856-7856 | 323.2 - 322.8 | 0.002 | 5s | successful scan
|
22:41 | ? | 209620 | 0123 | 7857 | 323.2 - 322.8 | 0.002 | 5s | First scan started by night shift
|
23:21 | 1.1e9 | 209620 | 0124 | 7858 | 323.2 - 322.8 | 0.002 | 5s | mbs crashed at 'sta ac'
|
23:32 | 1.3e9 | 209618 | 0125 | 7859 | 323.2 - 322.8 | 0.002 | 5s | e-cooler turned off
|
23:50 | 1.5e9 | 209xxx | 0126 | 7860 | 323.2 - 322.8 | 0.002 | 5s | the stop point was not set
|
23:53 | 1.5e9 | 209611 | 0127 | 7861 | 323.2 - 322.8 | 0.002 | 5s | DAQ2 must have crashed between 23:30 - 23:50
|
00:07 | 1.9e9 | 209xxx | 0128 | 7862 | 323.2 - 322.8 | 0.002 | 5s | mbs crashed at 'sta ac'
|
00:23 | 1.7e9 | 209623 | 0131 | 7864 | 323.2 - 322.8 | 0.002 | 5s | successful scan. we 'resl' after every measurement from now on. 'open file' is included in '@startup' now (ID:190).
|
01:08 | 1.6e9 | 209623 | 0132 | 7865 | 323.2 - 322.8 | 0.002 | 5s | successful scan
|
01:47 | 1.6e9 | 209623 | 0133 | 7866 | 323.2 - 322.8 | 0.002 | 5s | successful scan
|
02:35 | 1.3e9 | 209623 | 0134 | 7868 | 323.2 - 322.8 | 0.002 | 5s | successful scan
|
03:19 | 2.0e9 | 209622 | 0135 | 7869 | 323.2 - 322.8 | 0.002 | 5s | successful scan
|
04:04 | 1.3e9 | 209622 | 0136 | 7870 | 323.2 - 322.8 | 0.002 | 5s | successful scan
|
04:44 | 1.0e9 | 209622 | 0137 | 7871 | 323.2 - 322.8 | 0.002 | 5s | e-cooler turned off
|
05:25 | 1.9e9 | 209622 | 0140 | 7875 | 323.2 - 322.8 | 0.002 | 5s | successful scan. DAQ1 was started ~7s before DAQ2. The files between the last measurement an this one are essentially empty.
|
Carsten (19:00h): I notized that a lot of beam gets lost when starting scraping. I called Sergey Litvinov to help me to introduce some additional cooling/waiting (10s) after the ramp and before scraping and bunching. It increased the number of ions available for the measurement roughly by a factor of 3-5.
Some runs have wrong WM data. Set Wavelength is good.
Following files are saved differently, the command missed the 229Th in the end (/data.local2/BeamTimeTh22/229Thor -auto -rfio)
7850 (19:32)
7855 (21:56)
7856 (22:30) |
223
|
Wed Apr 13 14:29:04 2022 |
Carsten, Rodolfo, Sarper, David, Pierre-Michel, Max, Sebastian | Runs | Afternoon - morning shift runs 13.+14.04. |
Changed the wavelength scan range from 321.62 - 321.10 nm to 321.12 - 320.60 nm after one scan.
Time | SIS-intensity | cooler-HV | LMD-DAQ2 file nr | LMD-DAQ1 file nr | scan range(nm) | step width(nm) | dwell time(s) | particles counted | comments
|
14:28 | 1.9e9 | 209618 | 0254 | 7983 | 321.62 - 321.10 | 0.002 | 5s | 7950 |
|
15:35 | 1.7e9 | 209613 | 0255 | 7984 | 321.12 - 320.60 | 0.002 | 5s | 7100 | Wavelength range has changed starting from this scan
|
16:21 | 1.8e9 | 209612 | 0256 | 7985 | 321.12 - 320.60 | 0.002 | 5s | 6900 |
|
17:11 | 1.8e9 | 209619 | 0257 | 7986 | 321.12 - 320.60 | 0.002 | 5s | 7950 |
|
17:57 | 2.0e9 | 209618 | 0258-0259 | 7987 | 321.12 - 320.60 | 0.002 | 5s | 8900 |
|
18:48 | 2.1e9 | 209620 | 0260-0261 | 7988 | 321.12 - 320.60 | 0.002 | 5s | 9260 | After the scan was complete, we have realized that TCL 1064 computer is crashed.. fixed @ 20:05
|
20:07 | 2.1e9 | 209621 | 0262 | 7989 | 321.12 - 320.60 | 0.002 | 5s | 7800 |
|
20:56 | 2.0e9 | 209620 | 0263 | 7990 | 321.12 - 320.60 | 0.002 | 5s | 8190 | After closing file, we replaced the dye from the laser.
|
22:10 | 0 | 209620 | 0264 | 7991 | 321.12 - 320.60 | 0.002 | 5s | 0 | No beam due to failures in Unilac and SIS. NTCAP stopped 01:44, restarted 02:15
|
02:20 | 1.5e9 | 209620 | 0265 | 7992 | 321.12 - 320.60 | 0.002 | 5s | 0 | Electron cooler problem during scan, bad file.
|
02:52 | 1.4e9 | 209624 | 0266-0267 | 7993 | 321.12 - 320.60 | 0.002 | 5s | 3076 | --> CU mirror in all time !!!
|
03:44 | 1.6e9 | 209625 | 0268-0269 | 7994 | 321.12 - 320.60 | 0.002 | 5s | 5156 | --> CU mirror in all time !!!
|
04:35 | 1.7e9 | 209624 | 0270-0271 | 7995 | 321.12 - 320.60 | 0.002 | 5s | 3430 | --> CU mirror in all time !!!
|
05:27 | 1.6e9 | 209621 | 0272-0273 | 7996 | 321.12 - 320.60 | 0.002 | 5s | 3200 | --> CU mirror in all time !!!
|
06:17 | 1.6e9 | 209621 | 0274-0275 | 7997 | 321.12 - 320.60 | 0.002 | 5s | 3371 | low particle count since 22:00, see ID:225, --> CU mirror in all time !!!
|
07:24 | 1.5e9 | 209622 | 0276-0277 | 7998 | 321.12 - 320.60 | 0.002 | 5s | 3366 | --> CU mirror in all time !!!
|
08:33 | 1.6e9 | 209621 | 0278-0279 | 7999 | 321.12 - 320.60 | 0.002 | 5s | 2940 | ecooler jumped to 209615 during measurement, --> CU mirror in all time !!!
|
09:26 | 1.5e9 | 209618 | 0280 | 8000 | 321.12 - 320.60 | 0.002 | 5s | | aborted, request of Carsten
|
09:46 | 1.6e9 | 209621 | 0283-285 | 8003 | 321.12 - 320.60 | 0.002 | 5s | 2950 | small ecooler current changes (300mA injection and 50mA @ measurement), fragments survive in schottky @ lower frequencies (see attached pic1 and pic2), it seems to be that the cooler does not work correctly in "phase 1" (pic 1), --> CU mirror in all time !!!
|
11:28 | 1.75e9 | 209624 | 0287 | 8005 | 321.12 - 320.60 | 0.002 | 5s | ~1800 | ESR cooler back to 450mA (injection), 40mA (measurement), additional manual waiting time of 15s in machine 3 (after injection before ramping); ABORT laserscan on Carstens request after ~1 loop; Sergey arrived and we get some time for ion beam adjustements, --> CU mirror in all time !!!
|
12:23 | 1.5e9 | 209623 | 0289-0290 | 8007 | 321.12 - 320.60 | 0.002 | 5s | 8100 | Cu mirror is again automated and intensity in ESR is back up ; @12:42 increase of the width of the ion beam (pic3) @12:43 again normal width, intensity dropped significantly over time afterwards
|
13:09 | 1.55e9 | 209622 | 0291-292 | 8008 | 321.12 - 320.60 | 0.002 | 5s | 4852 | beam killed @ loop 2 scan nbr 253 (8 steps missed)
|
14:00 | 1e9 | 209622 | 0293-0294 | 8009 | 321.12 - 320.60 | 0.002 | 5s | 5509 |
|
14:48 | 9.5e8 | 209622 | 0295-0296 | 8010 | 321.12 - 320.60 | 0.002 | 5s | 5477 |
|
15:47 | 1e9 | 209622 | 0297-298 | 8011 | 321.12 - 320.60 | 0.002 | 5s | 6336 |
|
16:42 | 7e8 | 209619 | 0299 | 8012 | 321.12 - 320.60 | 0.002 | 5s | 2424 |
|
17:45 | 9.9e8 | 209620 | 0300 | 8013 | 321.12 - 320.60 | 0.002 | 5s | 5133 |
|
|
200
|
Sun Apr 10 15:16:19 2022 |
Carsten, Rodolfo, Sarper | Runs | Runs afternoon shifts 10.04 |
These are the measurement runs of the afternoon shift (10.04.).
Wavelength range is changed from 323.2 - 322.8 nm to 322.81 - 322.40 nm.
Time | SIS-intensity | cooler-HV | LMD-DAQ1 start-end | LMD-DAQ2 start-end | scan range(nm) | step width(nm) | dwell time(s) | comments
|
16:26 | 1.95e9 | 209620 | 0155-0155 | 7891-7891 | 322.81 - 322.40 | 0.002 | 5s | laser scan did not work, labview (Thorium_main.vi) communication issue
|
16:51 | 1.8e9 | 209620 | 0156-0156 | 7892-7892 | 322.81 - 322.40 | 0.002 | 5s |
|
17:33 | 1.6e9 | 209618 | 0157-0157 | 7893-7893 | 322.81 - 322.40 | 0.002 | 5s | 7894 particles on the counter
|
18:17 | 1.6e9 | 209618 | 0158-0158 | 7894-7894 | 322.81 - 322.40 | 0.002 | 5s | 8200 particles on the counter
|
19:06 | 1.8e9 | 209618 | 0159-0159 | 7895-7895 | 322.81 - 322.40 | 0.002 | 5s | 8650 particles on the counter
|
19:44 | 1.9e9 | 209618 | 0160-0160 | 7896-7896 | 322.81 - 322.40 | 0.002 | 5s | 8600 particles on the counter
|
20:24 | 1.7e9 | 209620 | 0161-0161 | 7897-7897 | 322.81 - 322.40 | 0.002 | 5s | 4200 particles on the counter
|
21:04 | 1.7e9 | 209619 | 0162-0162 | 7898-7898 | 322.81 - 322.40 | 0.002 | 5s | 8380 particles on the counter
|
21:45 | 1.8e9 | 209619 | 0163-0163 | 7899-7899 | 322.81 - 322.40 | 0.002 | 5s | 8550 particles on the counter
|
22:24 | 1.8e9 | 209619 | 0164-0164 | 7900-7900 | 322.81 - 322.40 | 0.002 | 5s | 8016 particles on the counter |
230
|
Thu Apr 14 17:47:55 2022 |
Carsten, Rodolfo, Konstantin, Sarper | Runs | Afternoon shift runs 14.04 changing the wavelength scan range | The new scan range is changed from 321.12 - 320.60 nm to 320.62 - 320.10 nm
Time | SIS-intensity | cooler-HV | LMD-DAQ2 file nr | LMD-DAQ1 file nr | scan range(nm) | step width(nm) | dwell time(s) | particles counted | comments
|
18:36 | 9.5e8 | 209618 | 0301 | 8014 | 320.62 - 320.10 | 0.002 | 5s | 6270 |
|
19:45 | 9.4e8 | 209615 | 0302 | 8015 | 320.62 - 320.10 | 0.002 | 5s | 5400 |
|
20:44 | 8.4e8 | 209618 | 0303 | 8016 | 320.62 - 320.10 | 0.002 | 5s | 4210 |
|
21:37 | 8.9e8 | 209616 | 0304 | 8017 | 320.62 - 320.10 | 0.002 | 5s | 4550 |
|
|
21
|
Fri Mar 18 16:51:27 2022 |
Carsten | DAQ | Main DAQ /MBS error | MBS error "TDC data ready wait" solved. Common stop trigger (20 kHz) was missing. (according to Sebastian) |
29
|
Wed Mar 23 15:38:15 2022 |
Carsten | General | Not all lights in the ESR can be switched off | Three of the lights in the ESR cannot be switched off. It seems that these lights are now "emergency lights" (with battery?). We will need to find dark plastik foilor similar to cover those lights during our beam time |
34
|
Thu Mar 24 17:10:33 2022 |
Carsten | DAQ | DAQ / MBS VUPROM TDC buffer errors | VUPROM TDC buffer errors potentially due to long TDC common Stop gate (>1ms from div 200).
Signal piped through coinc. unit gicv es shorter sginal (~200ns). This signal used as common stop seems to have cured the TDC buffer errors.. |
|