| ID | Date | Author | Category | Subject | Text |  | 
| 84 | Sun Mar 25 06:22:14 153 | Ken Ueberholz | Detectors | XUV-Detector Rates | Count rates were measured for the XUV- detector for a full circle:
 Cathode: -5V, shields: 0V, main coil 8A,
 |     | 
| 237 | Wed Apr 20 10:09:50 2022 | Rodolfo | Laser | Optic with spots | The average energy produced by the laser along the beamtime was about 10 mJ/puls. After
 about two weeks of beamtime some of the optics,
 |    | 
| 236 | Sat Apr 16 04:19:05 2022 | Patrick, Simon, Alex, Sarper | Runs | Runs night + morning shifts  16.04. | Runs of the night shift 16.04. after changing the wavelength range. The new range is 320.12
 - 319.859 nm. The step size was decreased
 |  | 
| 235 | Fri Apr 15 20:43:18 2022 | Konstantin | Laser | Dye changed | Dye of the laser system has been changed. UV laser power increased from ~8 mJ to 11
 mJ pulse energy.
 |  | 
| 234 | Fri Apr 15 12:53:25 2022 | Max, Danyal | Laser | checked laser pulse energy after change in wavelength range | previous scan range: the laser pulse energy @ 320.62 nm  was ~11
 mJ
 |  | 
| 233 | Fri Apr 15 12:42:18 2022 | Max, Danyal, Carsten, Konstantin, Patrick, Simon | General | laser wavelength range changed: 320.12 - 319.60 nm | Runs of the morning/afternoon/night shift.
 The wavelength range is now 320.12 - 319.60
 |   | 
| 232 | Thu Apr 14 22:44:40 2022 | Patrick, Simon, Danyal, Max | Runs | Runs night shift 14./15.04. | Runs of the night shift. The wavelength range is 320.62 - 320.10 nm.
 
 |  | 
| 231 | Thu Apr 14 19:46:46 2022 | Sarper & Konstantin & Rodolfo | Laser | Laser power | We checked the laser power before starting the new scan range.
 
 |  | 
| 230 | Thu Apr 14 17:47:55 2022 | Carsten, Rodolfo, Konstantin, Sarper | Runs | Afternoon shift runs 14.04 changing the wavelength scan range | The new scan range is changed from [B]321.12 - 320.60 nm to 320.62 - 320.10 nm[/B]
 
 |  | 
| 229 | Thu Apr 14 12:38:38 2022 | Sebastian | Detectors | XUV / Cu checkups | Check regularly if the connection to the XUV and Cu detectors are still active and the
 detectors move in (after injection) and out
 |  | 
| 228 | Thu Apr 14 12:27:18 2022 | Sebastian, Max | Detectors | Connection to XUV / Cu reestablished! | The connection to the XUV and Cu were lost during the nightshift.
 
 |  | 
| 227 | Thu Apr 14 10:57:11 2022 | Carsten | Accelerator | Maintanence UNILAC / Op training | We had no beam since about 1000. Also, we are still trying to find out why we have
 such a low intensity in the expereimnt.
 |  | 
| 226 | Thu Apr 14 08:41:42 2022 | Carsten | Accelerator | Low intensity at the experiment after series of failures during the night | After the recovery from the failures during the night, we see much lower intensity at
 the experiment (measured with the particle
 |  | 
| 225 | Thu Apr 14 06:29:18 2022 | Max, Sebastian | Accelerator | lesser ESR injection intensity | We now have less ESR injection intensity (see screenshot attached).
 
 |   | 
| 224 | Wed Apr 13 15:41:29 2022 | Rodolfo & Sarper | Laser | Laser status | We have checked the power of the laser and optimized it "a bit".
 
 |  | 
| 223 | Wed Apr 13 14:29:04 2022 | Carsten, Rodolfo, Sarper, David, Pierre-Michel, Max, Sebastian | Runs | Afternoon - morning shift runs 13.+14.04. | Changed the wavelength scan range from [B]321.62 - 321.10 nm[/B] to [B][B]321.12 - 320.60[/B]
 nm[/B] after one scan.
 |      | 
| 222 | Tue Apr 12 21:56:54 2022 | Volker, David, Pierre-Michel & Danyal, Alexandre, Sebastian | General | new laser wavelength scan range 321.62 - 321.10 nm | New wavelength scan range is [B]321.62 - 321.10 nm[/B]. Before the new scan range (compare
 old scan range in [URL=https://elog.gsi.de/esr/E142/215]
 |    | 
| 221 | Tue Apr 12 17:01:30 2022 | Konstantin | Detectors | Voltage PMT North | Voltage of PMT North has been increased from 2500 V to 2600 V. Additionally the threshold
 was adapted from 25 mV to 12 mV.
 |  | 
| 220 | Tue Apr 12 15:05:56 2022 | Rodolfo | Laser | Laser status | We have checked the laser power at 14:15 * 
 - Pump energy after Q-Ray @ 532nm: 559 mJ.
 |  | 
| 219 | Tue Apr 12 14:52:19 2022 | Rodolfo | Detectors | PMT Nord, Middle. Datasheets | Attached are the datasheets for the solar-blind PMTs.
 
 |   |