| ID | Date | Author  | Category | Subject | Text |  | 
| 1 | Mon Jul 26 17:15:47 2021 | Rodolfo | Laser | Quanta Ray - Water leak | On Thursday afternoon (22.07.2021) a water connector has broken and water has been spilled
 in the laser head.
 |   | 
| 2 | Mon Jul 26 17:58:52 2021 | Rodolfo | Laser | Water Filters | The water filters (deioninzing and particle) have been replaced.
 |   | 
| 3 | Wed Jul 28 13:31:22 2021 | Rodolfo | General | Air filters | Filters (Hepa-) inside the flow boxes have been replaced.
 |   | 
| 4 | Mon Aug  2 10:54:44 2021 | Rodolfo | Laser | Quanta Ray - Water leak in the power supply | After fixing the broken water connector in the laser head a new water leak appeared
 in the Quanta-Ray power supply.
 |   | 
| 5 | Fri Aug  6 10:23:00 2021 | Rodolfo | DAQ | atplaser on r4l-41 | The user [B]atplaser[/B] is now existing on the [B]R4L-XY[/B] nodes for the ESR group.
 
 |  | 
| 6 | Fri Aug  6 10:40:54 2021 | Rodolfo | DAQ | mbs in atplaser | The "MBS program" (data acquisition) is now located within atplaser@r4l-41, in the folder
 "th21":
 |  | 
| Draft | Wed Sep  8 21:44:55 2021 | Rodolfo | General | Preparation | [TABLE border="1"] [B]Status[/B]|[B]Arbeitspaket[/B]|[COLOR=chocolate][B]Kommentare[/B][/COLOR]
 |-
 |  | 
| 8 | Thu Oct 14 10:21:46 2021 | Rodolfo | Detectors | Dismounting Cu-Mirror | We have dismounted the parabolic Cu-Mirror at ESR on 13.10.2021
 |   | 
| 9 | Fri Nov  5 17:23:23 2021 | Rodolfo | DAQ | Dye trigger out | The dye laser offers different scan settings (see pages 65 - 67 of the user manual). We
 are using the following setting, see attached
 |   | 
| 10 | Fri Nov 19 15:50:44 2021 | Rodolfo | Accelerator | Laser windows at E-Cooler side | New laser viewports have been installed at the E-Cooler side of the ESR.
 
 |    | 
| 11 | Thu Mar  3 13:50:45 2022 | Rodolfo | Laser | Dye cell cracket | The "20 mm" dye cell used for the Oscillator and Pramplifier got damage. I supposed it
 was produced by the pump beam hitting on
 |   | 
| 12 | Thu Mar  3 17:21:26 2022 | Rodolfo | Detectors | MgF2 Windows | New reentrance viewports made of MgF2 have been installed at the ESR "Optical Detection
 Region". In the middle the old window (also
 |   | 
| 13 | Thu Mar  3 17:34:42 2022 | Rodolfo | Laser | Pump Laser | We have issues with our Pump Laser (Spectra Physics - Quanta Ray Pro). After the service
 made on mid Dezember (2021) the laser does
 |   | 
| 14 | Thu Mar  3 21:39:21 2022 | Rodolfo | Laser | Dye solution, DCM in Ethanol and DMSO | I have prepared a new dye solution of DCM in Ethanol and DMSO (1:1). The concentration
 of the "oscillator + preamplifier" is 0,3
 |   | 
| 18 | Thu Mar 17 17:37:49 2022 | Rodolfo | Accelerator | High voltage dividers for E-Cooler | Two dividers, from PTB-Braunschweig, have been deliver today. We will use them to monitor
 the electron-cooler voltage in situ.
 |   | 
| 20 | Fri Mar 18 09:18:38 2022 | Rodolfo | Accelerator | Vacuum leak, ODR | After the beaking out process we got a vacuum leak in one of the MgF2 windows (Referenz:
 PMT South) of the optical detection region
 |   | 
| 22 | Fri Mar 18 16:58:26 2022 | Rodolfo | Accelerator | Pressure at North-East Arc | The pressure at the north-east arc of ESR, where the laser window is located, looks
 suspicious. The sensor E01LF02 shows a value
 |    | 
| 23 | Mon Mar 21 09:18:28 2022 | Rodolfo | Accelerator | Pressure at North-East Arc | Our vacuum expert has reply. The "IZ Pump" in this region was off.
 
 |  | 
| 24 | Mon Mar 21 10:46:18 2022 | Rodolfo | DAQ | TDC & Scaler description channels | For the First Vuprom we have the following channel configuration (Stand:21.03.2021).
 
 |   | 
| 32 | Thu Mar 24 13:27:47 2022 | Rodolfo | DAQ | Disk space - LXG1297 | In our Linux computer (LXG1297: Laser spectroscopy) we have a Drive with 1.8 TB total disk space.
 300 GB are at the moment in use, but I can
 |   |