Nuclear hyperfine mixing in 229Th89+, Page 5 of 12
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Category --
Analysis
Calibration
DAQ
Laser
General
Runs
Detectors
Accelerator
233 Entries
Goto page
Previous
1
,
2
,
3
,
4
, 5,
6
...
10
,
11
,
12
Next
All
ID
Date
Author
Category
Subject
Text
28
Wed Mar 23 11:20:55 2022
Simon
Detectors
PMT operating voltages
During the testing of the PMTs the following
operating voltages were applied:
30
Wed Mar 23 16:16:42 2022
V. Hannen
Detectors
Control software for XUV and copper mirror detector
Attached you find a manual for the software
used to control the movement of the XUV detector
and the copper mirror detector.
31
Wed Mar 23 16:58:33 2022
V. Hannen
Detectors
Status copper mirror and XUV detectors
Over the past days, the parabolic copper mirror
and XUV detectors haven been prepared and
tested for the upcoming beamtime (see first
40
Thu Mar 31 11:49:54 2022
Konstantin
Detectors
HV-Supply of particle detectors
We cross-checked the cabeling of the particle
detectors north and south. Particle detector
south is connected to channel [B]HV5[/B]
42
Thu Mar 31 15:53:50 2022
Konstantin
Detectors
Control software for XUV and copper mirror detector
> Attached you find a manual for the software
used to control the movement of the XUV detector
and the copper mirror detector.
53
Fri Apr 1 15:27:00 2022
Rodolfo
Detectors
Nitrogen for UV-PMTs
There was a question concerning the nitrogen
we use to rinse the "Solar Blind PMTs".
54
Fri Apr 1 15:52:23 2022
Rodolfo
Detectors
UV PMT South
The "Solar Blind PMT" labeled as "PMT South"
has been installed by Simon and Max in the
gas target chamber on a CaF Viewport. The
55
Fri Apr 1 16:46:33 2022
Carsten
Detectors
All pressuzied air drives are tested now and are working properly
All pressuzied air drives are tested now and
are working properly
57
Fri Apr 1 18:30:38 2022
Carsten
Detectors
Positions / Voltages threshlds for particle detectors
[B]DC beam 238U92+ (205kV, e-beam)[/B]
We used the detector NA_SZ to determine the
central primary-beam (238U92+) position by
58
Fri Apr 1 22:01:14 2022
Konstantin
Detectors
PMT operating voltages
> During the testing of the PMTs the following
operating voltages were applied:
>
59
Fri Apr 1 23:12:37 2022
Patrick
Detectors
Scraper positions "only primary beam"
Scraper positions where there is only primary
beam for detector tests. Use only one outer
60
Fri Apr 1 23:47:45 2022
Carsten
Detectors
PMT thresholds / PMT north does not allow voltage abow ~ -1kV
Checked thresholds of PMT with beam and without
beam.
77
Sun Apr 3 11:40:48 2022
Shahab, Yuri
Detectors
245 MHz Resonator tuned to new frequency
resonance frequency changed from 243.2 MHz
to 244.692 MHz by reducing the value of both
of the plungers from 395 to 325. Now after
97
Tue Apr 5 13:24:40 2022
Kristian
Detectors
PMT Cu
HV cable was in wrong channel in power supply.
Now it is back to the correct position. Checked
connection at the PMT.
115
Wed Apr 6 19:39:08 2022
Ken Ueberholz
Detectors
LED installed
The UV-LED of Münster was connected over
channel 8 to the Messhütte. 6V are
supplied by the power supply (picture 2).
116
Wed Apr 6 21:03:25 2022
Ken Ueberholz
Detectors
Xuv-Detektor, further information
Some further information regarding the
xuv-detector and its components.
129
Thu Apr 7 05:55:17 2022
Ken Ueberholz
Detectors
XUV-Detector Mesytec crash
When the XUV-detector has to shut down unexpectedly,
it can happen that the Mesytek power supply
crashes and can't be
137
Thu Apr 7 14:01:22 2022
Sebastian, Max
Detectors
Mesytec reset
The Mesytec crate was turned off and on again.
It is again possible to communicate with
139
Thu Apr 7 14:13:27 2022
Danyal
Detectors
new PMT south
I have replaced the PMT south (looks at the
gas target).
in the hope that this will produce less dark
141
Thu Apr 7 16:45:10 2022
Detectors
Detector distances
Relativ distances of the detector