Tue May 4 17:54:08 2021, Helmut Weick, Simulations, updated LISE file
|
This file really has the optics like used in the last ESR experiments.
Now the transmission is also a little bit better. |
Fri May 7 17:12:52 2021, Kanika, Sergey, Yuri, Wolfram, Michael, Shahab, Runs, trigger time back to 50%
|
changed trigger time back to 50%
last file with 1% trigger:
|
Mon Jun 28 18:32:49 2021, Ruijiu, Shahab, DAQ, trigger signal connected to NTCAP and analyzers
|
|
Wed Jun 30 00:12:55 2021, Rui-Jiu Chen, Analysis, the ID of 72Ge setting
|
|
Thu Jul 1 15:25:42 2021, Rui-Jiu Chen, DAQ, template of NTCAP shift
|
Please check following two parameters every two hours into make sure the NTCAP is running well:
1. The latest recorded tdms files:
p:\E143\sc\**\**
|
Sun May 9 21:29:26 2021, Helmut, Wolfram, Yuri, Accelerator, target TE3UF shift
|
We see a very strong line at the left end of spectrum, stronger than all other lines.
When we shift the target TE3UF_H from -35mm to -37mm it gete weaker, but -37mm is the end of drive.
In the other direction it becomes worse. At -25mm completely new peaks.
|
Sat May 8 22:06:36 2021, Michael, Ruijiu, Helmut, Yuri, Wolfram, Sergey, Shahab, Runs, stopped data taking with the high resolution
|
last file names with this setting:
245: 2021.05.08.20.42.03.743.tiq
|
Sun May 9 18:41:33 2021, Rodostina, Oliver, Wolfram, Helmut, Yuri, Shahab, Runs, stopped data taking for energy change
|
last recorded filename:
E143-245MHz-2021.05.09.17.38.44.410.tiq
|
Fri Jul 2 19:57:12 2021, Shahab, Yuri, Wolfram, Liliana, Runs, stop DAQ
|
At 19:56 the DAQ is stopped.
The plan is to go back to the setting for Se.
Last files for the Br setting:
|
Fri May 7 22:48:33 2021, Chris, General, still running...
|
In anticipation of the imminent shift change, a snapshot of how things look. |
Wed Jun 30 02:12:46 2021, Shahab, Runs, still no beam in ESR: quadrupole magnets are down
|
still no beam in ESR: quadrupole magnets are down |
Fri May 7 03:33:11 2021, Liliana, Akash, Wolfram, Helmut, Shahab, General, status
|
At the moment we see a second peak to the left of each intense line.
The distance between the main peak and the shadow is roughly the same for each peak.
This hints to a sharp fall in the isochronicity curve.
|
Fri Jul 2 17:31:04 2021, Liliana, General, status
|
at 17:20 intensity was suddenly reduced.
Operators checked. Intensity was a bit low and fluctuating for a while (8e8 to 1e9)
Intensity (1.5e9) was recovered at 18:16 |
Sat May 8 21:10:24 2021, Michael, Ruijiu, Helmut, Yuri, Wolfram, Sergey, Shahab, Runs, started data taking with high resolution
|
after optimizing the scrapers we have reached the highest possible resolution in the isochronous mode.
starting data taking with this new settings.
|
Tue Jun 29 20:40:55 2021, Rui-Jiu Chen, DAQ, start NTCAP
|
Carrier Frequency:245MHz.
IQ rate 20MSamples/s
Reference level:-90 dBm
|
Thu Jul 1 23:07:47 2021, IK, KK, Runs, source
|
The change of the source happens now |
Thu Jul 1 21:35:32 2021, Shahab, Runs, some pics after 15dB amplification on 410
|
|
Wed Jun 30 13:57:14 2021, Yuri, Sergey, Accelerator, sextupoles + scraper positions
|
After setting up on 70Se
Sextupoles were adjusted to optimize the resolution of the 70Se peak. Set values are in the ESR logbook.
The SIS energy was shifted up to increase the number of 70Se.
|
Thu Jul 1 18:07:10 2021, Shahab, Runs, settings of the analyzers after changing the trigger position
|
|
Sun May 9 01:19:47 2021, Helmut, Sergey, Accelerator, scraper optmisation for 72Ge
|
To improve the isochronicity still in the 72Ge setting sextupoles and scrapers wer varies successfully.
1. E02DS_H -130 / 130mm - wide rect. peak
|
|