Entry  Thu Jul 1 21:35:15 2021, Shahab, DAQ, increase factor 4 in power for 410  
increase factor 4 in power for 410 

Entry  Fri May 7 18:08:35 2021, Kanika, Sergey, Yuri, Wolfram, Michael, Shahab, Runs, going back to the original energy 
going back to the original energy 441 MeV/u

last filenames with the previous energy:
Entry  Mon May 10 06:35:58 2021, Kanika, Alex, Shahab, Runs, going back to shot by shot recording with 410 detector 
going back to shot by shot recording with 410 detector
Entry  Sat May 8 01:33:25 2021, Helmut Weick, Simulations, frequency list for 70Se setting freq-lines-70Se.JPGfrag-freq-list.xlsx
EXCEL table with all possible fragments injected into ESR.
The path length in ESR, gamma_t and harmonic are adjusted to the 72Ge data. 
Some lifetimes are limited but all intense lines are >30s in lab system.
Entry  Fri Apr 23 13:47:55 2021, Jan Glorius, Collaboration, experiment proposal ESR_Two-Photon_proposal_final.pdf
 
Entry  Fri Jul 2 05:08:16 2021, Guy Leckenby (Canadian beaver team), Analysis, e143_analyser.py Summing Script e143_sum_ana.bashe143_comparison.C410MHz-07.01.22h-sum_20ms.png
I've written two scripts that others might find useful for the on-line analysis. 
  1. The first is a simple bash script that runs a for loop to run the e143_analyzer.py script for a sequence of start values (-s). You'll need to change
the increment and 
Entry  Fri Jul 2 12:18:35 2021, Pavlos, Alexandre, Accelerator, e-cooling 
Sergey Litvinov will now try to setup the e-cooler to cool the beam in the ESR. 
The data taking has been stopped (except the NTCAP).
Entry  Fri Jul 2 01:39:51 2021, IK, KK, Runs, drop of intensity 

We see a drop in beam intensity from 7E9 to 2E8 between 01:30 and 01:43
Entry  Fri Jul 2 03:10:03 2021, IK, KK, Runs, drop of intensity 
We see that intensity stabalized at 9E8 which is smaller then before. 
We neticed this at 2:50, keep observing.
Entry  Fri Jul 2 03:19:49 2021, IK, KK, Runs, drop of intensity 

And the intensity is back again to 5E9 at 03:20
Entry  Wed Jun 30 15:21:44 2021, Shahab, Runs, data synch on WWW server 
Data is being shared on the WWW server.
Time difference between the analyzers is in order of seconds:
Entry  Tue May 4 18:25:31 2021, Helmut Weick, Simulations, cutting of primary beam TE4-slits.JPGTE5-slits.JPG
The slits at TE4 and TE5 can be used to cut away the unwanted 78Kr beam (see pictures).
We do not want activation of the beamline. 78Kr35+ even has a chance of being injected.
Entry  Tue May 4 21:49:04 2021, Helmut Weick, Simulations, cut Brho by scrapers dispersion-oscillaction.JPG
The dispersion from the production target into the ESR is not matched.
This is not good for momentum acceptance, but we anyway want to cut the acceptance.
Dispersion will oscillate with the tune of ESR. After 3 turns we expect a maximum dispersion. 
Entry  Tue Jun 29 10:32:10 2021, Sergey, Helmut, Accelerator, cooler curves for tuning of isochronicity isoc_curves.JPGiso_curves_june_2021_1.xlsx
Variation of quadrupole E01QS03D to change gamma_t in isoc. mode
measured with 78Kr at 368.5 MeV/u on 28.06.2021 evening.
The shape of the three curves looks very similar they would only require a different beam velocity.
Entry  Sun May 9 18:50:23 2021, Helmut, Wolfram, Yuri, Accelerator, changed to 70Se 
18:45  changed SIS, ESR setting for 70Se without predrilling blind change.
E-SIS =  446.55 MeV/u, is centerd as before on TE3UF target grid.
set beamline after taret as 78Kr 36+ E = 337.375 MeV/u
Entry  Tue Jun 29 20:13:58 2021, Helmut, Sergey, Yuri, Accelerator, change to predrilling an 72Ge 
After optimisation of sextupoles we found a scraper position which makes a narrow peak and keeps 20% of the injected beam.
  GEEXDS2HA = +2.0 mm (out is +130mm)
  GE01DS_HI = -75 mm  (out is -130mm)
Entry  Sun May 9 22:31:23 2021, Helmut, Wolfram, Yuri, Accelerator, change to 72Ge 
we change back to 72Ge
just change SIS-energy       E = 441.0 MeV/u
beamline energy after target E = 392.9 MeV/u
Entry  Sun May 9 01:49:25 2021, Helmut, Sergey, Yuri, Accelerator, change to 52Mn 

It was done in steps:
isochronous 52Mn should come at Brho = 6.28239 Tm (gamma_t = 1.3955).
Entry  Fri May 7 18:43:13 2021, Kanika, Michael, Shahab, Runs, cave M experiment needs more spills rep.jpg
our pattern causes beam loss while scanning the biological probes in the Cave M bio experiment. They loose every other spill due to high request rate from
ESR.
Entry  Fri May 7 22:00:36 2021, Chris, Accelerator, brief beam loss 
Brief interruption in beam, ~21:42-21:51.