Entry  Sat Jul 3 08:12:22 2021, Dima, Yuri, General, Beam stop 
We stopped the beam at 08:10

The latest recorded tdms files:
Entry  Sat Jul 3 06:48:38 2021, The remote Canadian eager beavers (Guy & Iris), Analysis, Closer potential isomer tracks 70Se_close_pot_isomers.png
After looking through >800 shots from Jul 2nd 21h to Jul 3rd 05h, we couldn't find a single example of a "smoking gun" isomer decay. I.e. I'm talking about
the examples Liliana posted earlier. We did find many examples (roughly 10%) where the ion track spontaneously 
disappeared, but this shouldn't be the isomer as there was no frequency shift.
    Reply  Sat Jul 3 07:35:31 2021, The remote Canadian eager beaver (Iris), Analysis, Closer potential isomer tracks 410MHz-2021.07.02.21.42.36.139.tiq.png410MHz-2021.07.02.22.40.24.894.tiq.png
Here's a list of the spectra to look at for the potential isomer, taken btw 21:00 on July 2nd and 6:30 on July 3rd. Two examples attached.

Name Comment
Entry  Sat Jul 3 06:55:57 2021, Dima, David, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000761
 p:\E143\iq\IQ_2021-06-30_23-27-34\0003720
Entry  Sat Jul 3 06:49:55 2021, The remote Canadian eager beavers (Guy &Iris), Analysis, List of possible spectra with isomer decay 410MHz-2021.07.02.22.03.37.550.tiq.png
Attached is an example for the possible isomer (on the left) next to the 70Se (right). 

Here's the list with the files to look at, btw 21:00-6:30. Further analysis needs to be done offline. The slight frequency shift overnight made it a bit
Entry  Sat Jul 3 04:58:34 2021, Dima, David, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000735
 p:\E143\iq\IQ_2021-06-30_23-27-34\0003589
Entry  Sat Jul 3 04:33:50 2021, The remote Canadian eager beavers (Guy & Iris), Analysis, Slight shift in 70Se frequency 70Se-shift-21h-4h.png
Looks like the beam is slightly drifting...the 70Se peak frequency is slightly shifted to the left, by ~0.5 kHz compared to earlier spectra. Might be a
problem with the analyzer (?) or the storage ring energy (slightly lower?)... nothing drastical but to be observed.
Entry  Sat Jul 3 03:41:48 2021, The remote Canadian eager beavers (Guy & Iris), Analysis, Summed Spectra Summary 72Ge_sum.png72Br_sum.png70Se_not-scraped.png70Se_strong-scraped.png70Se_not-scraped_high_contrast.png
To summarise the method of bulk summing the spectra, I've created frequency vs time spectra by using the e143_analyser.py script to stack a series of -s
slices. I applied it to some of last runs data with 72Ge, to the 72Br data, last night's less-scraped 70Se, and tonight's more-scraped 70Se, respectively.
Entry  Sat Jul 3 03:07:43 2021, The remote Canadian eager beavers (Guy & Iris), Analysis, Some single spectra (410 MHz) from 21-24h July2-70Se-single-spectra-21-24h.pdf
Attached are some single spectra with a rough attempt to group them according to the different ions that appear.
Entry  Sat Jul 3 02:56:04 2021, Dima, David, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000707
 p:\E143\iq\IQ_2021-06-30_23-27-34\0003452
Entry  Sat Jul 3 01:28:08 2021, The remote Canadian eager beavers (Guy and Iris), Analysis, Summed spectra 410 MHz from 21:00-23:59 (70Se) July2-21-0h-410MHz_AllSpectra_70Se.png
Here's a picture with all injections with an ion in the spectrum (empty ones were removed- list below). The time slices are 0-0.5-1-1.5-2s, then in 0.2s
steps up to 3s. Not really anything to see :-(  The previous shift was right, looking at single spectra might be more useful. I'll group the pictures and
upload some "interesting" ones.
Entry  Sat Jul 3 00:59:01 2021, Dima, David, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000680
 p:\E143\iq\IQ_2021-06-30_23-27-34\0003322
Entry  Fri Jul 2 23:09:22 2021, Dima, David, Liliana, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000655
 p:\E143\iq\IQ_2021-06-30_23-27-34\0003199
Entry  Fri Jul 2 21:07:31 2021, Liliana, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000627
 p:\E143\iq\IQ_2021-06-30_23-27-34\0003062
Entry  Fri Jul 2 20:33:44 2021, Yuri, Accelerator, 70Se setting with closed scrapers 
We tune back to 70Se.
The scrapers stay closed at EEXDS2HA=0 mm, EEXDS1HG=+5 mm
"Single"-particle run
Entry  Fri Jul 2 20:01:16 2021, Liliana, Runs, Some plots from the Br setting 6x
 
Entry  Fri Jul 2 19:57:12 2021, Shahab, Yuri, Wolfram, Liliana, Runs, stop DAQ  
At 19:56 the DAQ is stopped. 
The plan is to go back to the setting for Se. 
Last files for the Br setting:
Entry  Fri Jul 2 19:06:18 2021, Liliana, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000600
 p:\E143\iq\IQ_2021-06-30_23-27-34\0002931
Entry  Fri Jul 2 17:31:04 2021, Liliana, General, status 
at 17:20 intensity was suddenly reduced. 
Operators checked. Intensity was a bit low and fluctuating for a while (8e8 to 1e9)
Intensity (1.5e9) was recovered at 18:16
Entry  Fri Jul 2 17:27:56 2021, Liliana, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000577
 p:\E143\iq\IQ_2021-06-30_23-27-34\0002818
Entry  Fri Jul 2 16:14:17 2021, Yuri, Accelerator, Scrapers 4 72Br 1C28A49A-5FA1-4A81-8675-3ED9660FD793.png
Starting 15:15
The scrapers are moved very much close to each other to eliminate all background particles and leaving basically single ions injected for 72Br. Do not
wonder, this means that also many empty files are created.