  nuclear two-photon decay, Page 1 of 12  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Categorydown Subject Text Attachments
  2   Wed Apr 28 09:36:39 2021 Helmut WeickSimulationsLISE file for fragments from TE3UF into ESRUncooled beam on target at TE3UF with dispersion
and slit in TE beamlne and realistic injection
into ESR.
 E143_weick.pptxE143_TE-ESR.lpp 
  3   Tue May 4 13:26:40 2021 YuriSimulationsExpected spectrum 72GeA       Z      M/q                Int    difference
in kHz@245MHz
68 30 2.263614752 35 -933.1
  
  4   Tue May 4 17:54:08 2021 Helmut WeickSimulationsupdated LISE fileThis file really has the optics like used
in the last ESR experiments.
Now the transmission is also a little bit
 E143_TEline-ESR-2.lpp 
  5   Tue May 4 18:25:31 2021 Helmut WeickSimulationscutting of primary beamThe slits at TE4 and TE5 can be used to cut
away the unwanted 78Kr beam (see pictures).
We do not want activation of the beamline.
 TE4-slits.JPGTE5-slits.JPG 
  6   Tue May 4 21:49:04 2021 Helmut WeickSimulationscut Brho by scrapersThe dispersion from the production target
into the ESR is not matched.
This is not good for momentum acceptance,
 dispersion-oscillaction.JPG 
  8   Thu May 6 00:32:57 2021 Helmut WeickSimulationsGICOSY file for TE beamline and ESRThis file has several options:
start in SIS, at TE3UF target or inside ESR,
choose with GOTO LABEL (G L)after start system
 SIS-TE-ESR-isoc-std.datTE-ESR.JPG 
  64   Sat May 8 01:33:25 2021 Helmut WeickSimulationsfrequency list for 70Se settingEXCEL table with all possible fragments injected
into ESR.
The path length in ESR, gamma_t and harmonic
 freq-lines-70Se.JPGfrag-freq-list.xlsx 
  30   Fri May 7 04:01:51 2021 ShahabRunsPicture after scrapingthis picture is after scraping by helmut,
showing the 410 MHz detector, that is we
would expect an isomer where the marker M1
 pic.jpg 
  31   Fri May 7 04:26:54 2021 ShahabRuns245 MHz resonator extra 20dB gain offmade sure that the extra 20dB amplifier is
off.
  
  32   Fri May 7 04:39:00 2021 Liliana, Akash, Wolfram, Helmut, ShahabRunsData taking startsFile start being recorded at 4:38 am 
Sync with the server is working. 
  
  49   Fri May 7 16:17:21 2021 Sergey, Yuri, Wolfram, ShahabRunsnew sextupole settingnew sextupole setting, isomer not visible
yet.
  
  50   Fri May 7 17:02:51 2021 Kanika, Sergey, Yuri, Wolfram, Michael, ShahabRunsnew sextupole setting 2There is new sextupole settings, but the scrapers
remain like last night (Helmut setting last
night.)
  
  51   Fri May 7 17:12:14 2021 Kanika, Sergey, Yuri, Wolfram, Michael, ShahabRunsEnergy change -6 MeV/uchanged the energy down to 435 MeV/u   
  52   Fri May 7 17:12:52 2021 Kanika, Sergey, Yuri, Wolfram, Michael, ShahabRunstrigger time back to 50%changed trigger time back to 50%

last file with 1% trigger: 
  
  53   Fri May 7 17:35:22 2021 Kanika, Sergey, Yuri, Wolfram, Michael, ShahabRunsEnergy change +6 MeV/uWe will now go up in energy to 447 MeV (+6
MeV) from the original energy
  
  54   Fri May 7 18:08:35 2021 Kanika, Sergey, Yuri, Wolfram, Michael, ShahabRunsgoing back to the original energygoing back to the original energy 441 MeV/u

last filenames with the previous energy:
  
  55   Fri May 7 18:43:13 2021 Kanika, Michael, ShahabRunscave M experiment needs more spillsour pattern causes beam loss while scanning
the biological probes in the Cave M bio experiment.
They loose every other spill due to high
 rep.jpg 
  56   Fri May 7 19:56:10 2021 Kanika, Michael, ShahabRunsZOOM session restartrestart zoom session   
  58   Fri May 7 20:34:27 2021 Kanika, Michael, ShahabRunsback to 15 sec recordingnow we are going back to 15 sec operation.
Cave M (bio) operation is over
  
  77   Sat May 8 17:29:54 2021 Yuri, Sergey, Wolfram, Michael, ShahabRunsrecording Kr decay measurement on NTCAPUc = 250mA
decay Kr 78, 476 MeV/u
  