HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018
  nuclear two-photon decay, Page 1 of 12  Not logged in ELOG logo
Entry  Wed Apr 28 09:36:39 2021, Helmut Weick, Simulations, LISE file for fragments from TE3UF into ESR E143_weick.pptxE143_TE-ESR.lpp
Uncooled beam on target at TE3UF with dispersion and slit in TE beamlne and realistic injection into ESR.
Now tuned for 72Ge but can easily be modified to other fragment settings. 
The target thickness may need adjustemet after measurement.
Entry  Tue May 4 13:26:40 2021, Yuri, Simulations, Expected spectrum 72Ge 
A       Z      M/q                Int    difference in kHz@245MHz
68 30 2.263614752 35 -933.1
70 31 2.255131564 124 -457.0
Entry  Tue May 4 17:54:08 2021, Helmut Weick, Simulations, updated LISE file E143_TEline-ESR-2.lpp
This file really has the optics like used in the last ESR experiments.
Now the transmission is also a little bit better.
Entry  Tue May 4 18:25:31 2021, Helmut Weick, Simulations, cutting of primary beam TE4-slits.JPGTE5-slits.JPG
The slits at TE4 and TE5 can be used to cut away the unwanted 78Kr beam (see pictures).
We do not want activation of the beamline. 78Kr35+ even has a chance of being injected.
Entry  Tue May 4 21:49:04 2021, Helmut Weick, Simulations, cut Brho by scrapers dispersion-oscillaction.JPG
The dispersion from the production target into the ESR is not matched.
This is not good for momentum acceptance, but we anyway want to cut the acceptance.
Dispersion will oscillate with the tune of ESR. After 3 turns we expect a maximum dispersion. 
Entry  Thu May 6 00:32:57 2021, Helmut Weick, Simulations, GICOSY file for TE beamline and ESR SIS-TE-ESR-isoc-std.datTE-ESR.JPG
This file has several options:
start in SIS, at TE3UF target or inside ESR, choose with GOTO LABEL (G L)after start system (S S).
Depending on the choice select different start beam parameters at top of file, others comment out.
Entry  Sat May 8 01:33:25 2021, Helmut Weick, Simulations, frequency list for 70Se setting freq-lines-70Se.JPGfrag-freq-list.xlsx
EXCEL table with all possible fragments injected into ESR.
The path length in ESR, gamma_t and harmonic are adjusted to the 72Ge data. 
Some lifetimes are limited but all intense lines are >30s in lab system.
Entry  Fri May 7 04:01:51 2021, Shahab, Runs, Picture after scraping pic.jpg
this picture is after scraping by helmut, showing the 410 MHz detector, that is we would expect an isomer where the marker M1 is, i.e. at 2.2kHz on the
left side, which we unfortunately don’t see (yet).
Entry  Fri May 7 04:26:54 2021, Shahab, Runs, 245 MHz resonator extra 20dB gain off 
made sure that the extra 20dB amplifier is off.
Entry  Fri May 7 04:39:00 2021, Liliana, Akash, Wolfram, Helmut, Shahab, Runs, Data taking starts 
File start being recorded at 4:38 am 
Sync with the server is working. 
Entry  Fri May 7 16:17:21 2021, Sergey, Yuri, Wolfram, Shahab, Runs, new sextupole setting 
new sextupole setting, isomer not visible yet.
Entry  Fri May 7 17:02:51 2021, Kanika, Sergey, Yuri, Wolfram, Michael, Shahab, Runs, new sextupole setting 2 
There is new sextupole settings, but the scrapers remain like last night (Helmut setting last night.)
Entry  Fri May 7 17:12:14 2021, Kanika, Sergey, Yuri, Wolfram, Michael, Shahab, Runs, Energy change -6 MeV/u 
changed the energy down to 435 MeV/u
Entry  Fri May 7 17:12:52 2021, Kanika, Sergey, Yuri, Wolfram, Michael, Shahab, Runs, trigger time back to 50% 
changed trigger time back to 50%

last file with 1% trigger: 
Entry  Fri May 7 17:35:22 2021, Kanika, Sergey, Yuri, Wolfram, Michael, Shahab, Runs, Energy change +6 MeV/u 
We will now go up in energy to 447 MeV (+6 MeV) from the original energy

last file name with previous energy:
Entry  Fri May 7 18:08:35 2021, Kanika, Sergey, Yuri, Wolfram, Michael, Shahab, Runs, going back to the original energy 
going back to the original energy 441 MeV/u

last filenames with the previous energy:
Entry  Fri May 7 18:43:13 2021, Kanika, Michael, Shahab, Runs, cave M experiment needs more spills rep.jpg
our pattern causes beam loss while scanning the biological probes in the Cave M bio experiment. They loose every other spill due to high request rate from
ESR.
Entry  Fri May 7 19:56:10 2021, Kanika, Michael, Shahab, Runs, ZOOM session restart 
restart zoom session
Entry  Fri May 7 20:34:27 2021, Kanika, Michael, Shahab, Runs, back to 15 sec recording 
now we are going back to 15 sec operation. Cave M (bio) operation is over
Entry  Sat May 8 17:29:54 2021, Yuri, Sergey, Wolfram, Michael, Shahab, Runs, recording Kr decay measurement on NTCAP 
Uc = 250mA
decay Kr 78, 476 MeV/u
ELOG V3.1.5-fc6679b