HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038 E0075 E0203_E0018
  nuclear two-photon decay, Page 8 of 12  Not logged in ELOG logo
Entry  Thu Jul 1 16:27:57 2021, Andrew Nic, General, NTCAP parameters 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000233
 p:\E143\iq\IQ_2021-06-30_23-27-34\0001138
Entry  Thu Jul 1 21:15:01 2021, Andrew Nic, DAQ, NTCAP Status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000299
 p:\E143\iq\IQ_2021-06-30_23-27-34\0001462
Entry  Tue Jun 29 21:12:15 2021, Kanika, Shahab, Runs, Moving the resonance frequency of the 245 MHz resonator  e143_resonance_change_2.PNG
moving in the plungers:

before: 400
Entry  Sat May 8 07:14:00 2021, Akash, Nic, Jelena, Zsolt, General, Morning shift entry 
Things look ok. No settings have been changed...

Analysis attempts are going on...
Entry  Thu Jul 1 00:09:28 2021, David, Liliana, General, Low beam intensity for few minutes 
For few minutes (starting at 00:05) beam intensity went down. Same as it was reported by the previous shift. 
Until 00:27 beam had lower intensity than before (3e8) 
Now intensity is back to 5e8.
Entry  Sat Jul 3 06:49:55 2021, The remote Canadian eager beavers (Guy &Iris), Analysis, List of possible spectra with isomer decay 410MHz-2021.07.02.22.03.37.550.tiq.png
Attached is an example for the possible isomer (on the left) next to the 70Se (right). 

Here's the list with the files to look at, btw 21:00-6:30. Further analysis needs to be done offline. The slight frequency shift overnight made it a bit
Entry  Thu Jul 1 23:46:17 2021, Iris, General, Less beam after gas bottle change? Comparison-21h-2340h.png
Looks like there is a bit less beam now in the ring. I just looked at one spectra from before the gas bottle change and after...
    Reply  Thu Jul 1 23:54:43 2021, Iris, General, Less beam after gas bottle change? Comparison-21h-2350h.png
No, everything okay! Must have had a very good earlier run to compare.

> Looks like there is a bit less beam now in the ring. I just looked at one spectra from before the gas bottle change and after...
Entry  Thu Jun 24 22:05:11 2021, Helmut Weick, Accelerator, LISE files for 72Ge, 70Se, 52Mn settings E143_TEline-ESR-72Ge.lppE143_TEline-ESR-70Se.lppE143_TEline-ESR-52Mn.lpp
This is just a Brho selection by the ESR based on SIS-energy used, 
energy-loss in target with calibrated thickness and momentum spread by the reaction (Goldhaber formula).
Production cross sections are by EPAX 3.1
Entry  Wed Apr 28 09:36:39 2021, Helmut Weick, Simulations, LISE file for fragments from TE3UF into ESR E143_weick.pptxE143_TE-ESR.lpp
Uncooled beam on target at TE3UF with dispersion and slit in TE beamlne and realistic injection into ESR.
Now tuned for 72Ge but can easily be modified to other fragment settings. 
The target thickness may need adjustemet after measurement.
Entry  Sat May 8 11:42:21 2021, Yuri, Accelerator, KPs 
EO1KP03 was on = -44.9 A
E01KP05 was off, now is on = 3.67 A
The beam is on the right frequency, but the width is still very broad.
Entry  Thu Jul 1 01:35:15 2021, David, Liliana, General, Ion source change 
Changing ion source, no beam expected for the next 30 minutes.

2:15--> Beam is back, intensity not as high as before but will increase in the next few minutes as the source gets hotter.
Entry  Fri May 7 09:56:43 2021, Yuri, Calibration, Identification Verification 
With closed scrapers there are only a few weak lines.
Open temporarily all scrapers in the ESR to write down the frequencies. 
Entry  Fri Jun 25 21:47:24 2021, Yuri, Analysis, Identification Spectrum_possible_ID.pngID_2nd_Part.jpg
Attached are two files with a proposed particle identification.
Different colors indicate different harmonic numbers
Entry  Wed Jun 30 19:08:25 2021, Rui-Jiu Chen, Analysis, ID of 70Se spectrum recorded in May output_126.tofplot_242.0_245.0.pngplot_242.0_245.0.rootplot_242.0_245.0.pdf
 
Entry  Wed Jun 30 00:20:10 2021, Rui-Jiu Chen, Analysis, ID of 70Se setting on May plot_242.0_245.0.pngplot_242.0_245.0.pdfplot_242.0_245.0.rootoutput_126.tof
This is an old spectrum which was recoded on May.
Entry  Wed Jun 30 13:05:08 2021, Rui-Jiu Chen, Analysis, ID of 70Se 2021-06-30_11_54_00.png2021-06-30_11_54_00.pdf2021-06-30_11_54_00.rootoutput_127.tofoutput_128.tof
This is the latest ID of 70Se setting.
Entry  Thu May 6 00:32:57 2021, Helmut Weick, Simulations, GICOSY file for TE beamline and ESR SIS-TE-ESR-isoc-std.datTE-ESR.JPG
This file has several options:
start in SIS, at TE3UF target or inside ESR, choose with GOTO LABEL (G L)after start system (S S).
Depending on the choice select different start beam parameters at top of file, others comment out.
Entry  Fri May 7 10:46:40 2021, Yuri, Accelerator, GE02DS3HG 
The scraper is blocked at -10 mm and -unfortunately- blocks the beam in the ESR. Uli Popp is taking care.
Entry  Thu Jul 1 16:47:15 2021, Andrew Nic, Runs, Frequency shift 
The freqency suddenly shifted at time 16:11:47 and remained shifted until now 

The ESR status in the monitor stayed blue. No obvious sign that a magnet was down. The operators are checking
ELOG V3.1.5-fc6679b