ID |
Date |
Author |
Category |
Subject |
Text |
|
33
|
Thu May 13 01:13:06 2021 |
Sebastian | General | Bunching frequencies | relating to Danyals ID 25 post are the current
bunching frequencies:
|
|
34
|
Thu May 13 01:21:30 2021 |
Sebastian | General | Current schedule ... so far | 1.) check h=2,4,6,7,8,10 .... bunching frequencies
with different amplitudes (signalgenerator),
Ecooler ON, Laser OFF --> record schottky |
|
35
|
Thu May 13 01:55:15 2021 |
Sebastian | General | ESR amplifier reset / laser check | we had to go into the ESR because the amplifiers
hooked up. both amplifiers were resetted!
|
|
36
|
Thu May 13 02:42:58 2021 |
Sebastian | General | Lasershutter ESR Entrance?! | attached should be the name of the entrance
laser shutter. just in case somebody will
close it ;) |
|
38
|
Thu May 13 03:35:25 2021 |
Lars | General | Status: Current schedule ... so far | 1.) so far:
h = 2, 4, 6, 7, 8, 10, 12, 14, 16, 18, 20,
30
|
|
39
|
Thu May 13 18:34:54 2021 |
Ken Ueberholz | General | What happened scince shift change at 4pm | Ion frequency shifts with laser, both manually
and scanned, without bunches: successful
Bunching with 7 and 20 bunches: successful
|
|
40
|
Thu May 13 20:18:10 2021 |
Benedikt | General | New f_rev | The ions were changed to a different speed
today at 2 PM. The new revolution frequency
is now 1.291278 MHz. |
|
41
|
Thu May 13 21:00:48 2021 |
Benedikt | General | New reprate of the UV laser | The lasersystem now operates at a reparte
of 9.038946 MHz. This is 7 times f_rev (see
previous post).
|
|
42
|
Thu May 13 23:42:37 2021 |
Ken Ueberholz | General | What was done | In this shift a number of successful Schottky
measurements were done:
With fixed laser wavelength, while varying |
|
43
|
Fri May 14 01:28:04 2021 |
Sebastian | General | "new" laser wavelength | Minor changes in electron cooler voltage (~+13V,
now 66903V measured by DMM) leads to that
we had to shift the laser wavelength to:
|
|
44
|
Fri May 14 01:34:44 2021 |
Team | General | strange XUV Anode signal | We see a strange behavior of the anode signal
when we bunch the ion beam and electron cooler
is on.
|
|
45
|
Fri May 14 04:50:46 2021 |
Team #Night | General | Scraper Tests Ion / Laser Beam | laser is 4-6mm below the ion beam.
It could be that the interaction between
both beams came only from the interaction |
|
47
|
Fri May 14 06:35:55 2021 |
Team #Night | General | Adjustment of Laser | we increased the height of the laser beam
TEM Settings
|
|
48
|
Fri May 14 07:20:18 2021 |
Team #Night | General | actual bunching frequency | 25,82556 MHz
h = 20 |
|
Draft
|
Fri May 14 07:33:42 2021 |
Team #Night | General | ecooler central frequency shifted relative to bunch central frequency | |
|
50
|
Fri May 14 08:55:53 2021 |
Sebastian | General | ToDO 14.5 ...so far | 1.) ion lasser overlap and scraper test
2.) change bunching frequency to middle of |
|
51
|
Fri May 14 09:00:55 2021 |
Sebastian | General | UNILAC Problems | ~30 min downtime
--> LASER ADJUSTEMENTS! |
|
57
|
Fri May 14 16:37:01 2021 |
Benedikt | General | Status update | Right now, we have to adjust the ion beam
a bit to overlap better with the laser beam.
We keep the laser wavelength at resonance |
|
58
|
Fri May 14 21:43:40 2021 |
Sebastian | General | "problems accelerator" | There are cooling problems of some accelerator
devices
short break, hopefully :)
|
|
61
|
Sat May 15 03:39:16 2021 |
Team | General | actual revolution frequency | frev = 1,2912735 MHz |
|