  Laser Cooling Experiment 2021, Page 3 of 5  Not logged in ELOG logo
Entry  Fri May 14 04:50:46 2021, Team #Night, General, Scraper Tests Ion / Laser Beam 
laser is 4-6mm below the ion beam.
It could be that the interaction between both beams came only from the interaction between the laser halo with the ion beam ?!
Entry  Fri May 14 01:34:44 2021, Team, General, strange XUV Anode signal Screenshot_(68).png
We see a strange behavior of the anode signal when we bunch the ion beam and electron cooler is on.

peak structure... ---> we play now with the bunching amplitude 
Entry  Fri May 14 01:28:04 2021, Sebastian, General, "new" laser wavelength 
Minor changes in electron cooler voltage (~+13V, now 66903V measured by DMM) leads to that we had to shift the laser wavelength to:

1028,965nm 
Entry  Thu May 13 23:42:37 2021, Ken Ueberholz, General, What was done Schottky1.jpegSchottky2.jpegSchottky3.jpegSchottky4.jpeg
In this shift a number of successful Schottky measurements were done:
With fixed laser wavelength, while varying the wavelength, with different bunching and more (see logfile 1 for more info: line 53 to at least 107).
The detector software sometimes files to change the current of the power supplies, if this happens a simple restart of the GUI fixes the problem.
Entry  Thu May 13 21:00:48 2021, Benedikt, General, New reprate of the UV laser 
The lasersystem now operates at a reparte of 9.038946 MHz. This is 7 times f_rev (see previous post).

In the future, the laser-bunch-timing can be adjusted.
Entry  Thu May 13 20:18:10 2021, Benedikt, General, New f_rev 
The ions were changed to a different speed today at 2 PM. The new revolution frequency is now 1.291278 MHz.
Entry  Thu May 13 18:34:54 2021, Ken Ueberholz, General, What happened scince shift change at 4pm 
Ion frequency shifts with laser, both manually and scanned, without bunches: successful
Bunching with 7 and 20 bunches: successful
Tried laser scans with bunches: unsuccessful
Entry  Thu May 13 01:21:30 2021, Sebastian, General, Current schedule ... so far 
1.) check h=2,4,6,7,8,10 .... bunching frequencies with different amplitudes (signalgenerator), Ecooler ON, Laser OFF --> record schottky and "normal" DAQ

2.) Ecooler ON, Bunching ON, Laser ON (wavelength fixed and/or scanned)
    Reply  Thu May 13 03:35:25 2021, Lars, General, Status: Current schedule ... so far 
1.) so far: 
h = 2, 4, 6, 7, 8, 10, 12, 14, 16, 18, 20, 30
Amplitudes: (10, 50, 100, 150, 200, 250) mV
Entry  Thu May 13 02:45:29 2021, Sebastian, Analysis, ESR pressure 8x
 
Entry  Thu May 13 02:42:58 2021, Sebastian, General, Lasershutter ESR Entrance?! IMG_20210513_020027_resized_20210513_024049198.jpg
attached should be the name of the entrance laser shutter. just in case somebody will close it ;)
Entry  Thu May 13 01:55:15 2021, Sebastian, General, ESR amplifier reset / laser check IMG_20210513_014345_resized_20210513_015540959.jpgIMG_20210513_014353_resized_20210513_015541291.jpg
we had to go into the ESR because the amplifiers hooked up. both amplifiers were resetted!

we also checked why we didnt see the laser at the exit window.
Entry  Thu May 13 01:13:06 2021, Sebastian, General, Bunching frequencies 
relating to Danyals ID 25 post are the current bunching frequencies:

h=2      -->     2,5823668 MHz
Entry  Thu May 13 01:05:45 2021, Danyal, DAQ, more stability by bunching 
Because the C3+ part of the ion beam is properly bunched, it is no longer so sensitive to the drifts caused by the e-cooler. 
In the O4+ part of the ion beam these drifts can still be seen. 
Entry  Thu May 13 01:01:27 2021, Danyal, DAQ, bunched ion beam bunched_-_signal.jpgbunched_-_Schottky.jpgzoom_bunched_-_Schottky.jpg
 
Entry  Thu May 13 00:58:53 2021, Danyal, DAQ, unbunched ion beam not_bunched_-_signal.jpgnot_bunched_-_Schottky.jpg
 
Entry  Wed May 12 23:45:23 2021, Ken Ueberholz, General, Laser does not reach the exit window 
High rates on the detector at 50mm positions, laser does not seem to reach the exit window.
Entry  Wed May 12 23:36:18 2021, Ken Ueberholz, DAQ, VI change 
carbon main vi - kopie is now in operation

here, in keysight.vi the input settings for the new impedence for the multimeter are now hopefully correct --> THIS SHOULD BE CHECKED IF THE RING IS OPEN
Entry  Wed May 12 22:57:41 2021, Sebastian, General, Laser Reprate 
laser reprate is seven times the revoolution frequency: 9.038283 MHz
pulse length: 735ps
Entry  Wed May 12 22:48:25 2021, Sebastian, General, DSG Control SCPI Commands 
Open Ultra Sigma
Press LAN
Press Search, after a while the whole rigol devices are shown. Press ok
Entry  Wed May 12 22:35:33 2021, Danyal, General, frev and fb 
Schottky frequency (189th harmonic) = 244.033662 MHz

revolution frequency  frev = 1.2911834 MHz