IDdown Date Author Category Subject Text Attachments
  113   Tue Jun 6 09:33:00 2023 RodolfoLaserFiber couplerCobra's new fiber-coupling unit for wavelength
reading.
 Cobra_FiberCoupler.jpg 
  112   Wed Jan 18 13:02:12 2023 RodolfoLaserTesting WS6 with CobraTesting the WS6 (S.N. 3950) together with
the Cobra. 
 WS6_640-639.8_0.005_18-01-2023_11.23.png 
  111   Fri Jan 13 17:05:22 2023 RodolfoLaserTesting WS6Testing the new Wavemeter (HighFinesse, WS6,
SN3950) with the QRAY laser light @ 532 nm.
Multimode fiber von High Finesse:FC/PC S
 WS6_3950_QRayWavelength_13-01-2022.png 
  110   Thu Jun 30 11:12:21 2022 CarstenAnalysisUpdated Go4 Analysis with small Bugfix (PMTOverWavelength SPectra)Here attached is a more recentversion of the
Go4 Analysis Code with some smaller bugfixes.
For adaequate *.C files please have alook
 208Bi_20220629_fix.tgz 
  109   Fri Jun 3 12:01:17 2022 DanyalDetectorsswitched off XUV detector on 1 June ~17:00 I have switched off the XUV detector on 1
June at about 17:00. 
The high voltages of the MCP (in ESR laser
  
  108   Wed Jun 1 17:20:04 2022 RodolfoLaserHeNe @ WS7   HeNe_WS7_01-06-2022_1.png 
  107   Wed Jun 1 08:39:50 2022 Kristian, KonstantinCalibrationWavemeter readingWe recorded files with high wavemeter readout
rate and saved it at the atplaser network
drive (Q:) - Bismuth - wavemeter folder.
  
  106   Wed Jun 1 00:16:02 2022 Konstantin, SimonDAQTiming 209Bi thick targetTiming for the final measurements on 209Bi
was determined for the new frequency 1.93777MHz.
Peak positions are
 Timing_209Bi_final.png 
  105   Wed Jun 1 00:03:08 2022 Konstantin, Simon, KristianRuns209-Bi runs[TABLE border="1"]
Time | SIS-intensity | ESR-intensity after
orbit change| cooler-HV | cooler current
  
  104   Tue May 31 21:58:55 2022 Max, RodolfoLaserMRC Settings for 209Bi We have change the laser settings for the
spectroscopy of 209Bi. 
 MRC_209Bi_31-05-2022_2157.png 
  103   Tue May 31 21:08:04 2022 Carsten, MaxDetectorsXUV detector automation offWe deactivated the automation of the XUV detector.
It stays out now.
  
  102   Tue May 31 19:59:49 2022 Carsten, DanyalAcceleratorchange in frequency mismatch 208Bi --> 209Bitime = 20:00 

The RF has been adjusted so that it bunches
  
  101   Tue May 31 19:37:30 2022 Carsten, Max, WilfriedDetectorsSASZ and NASZ voltages switched offSASZ and NASZ voltages were switched off bevor
we went back to 209Bi. Laser beam stabilization
turned off.
  
  100   Tue May 31 19:32:56 2022 Carsten, Wilfried, MaxCalibrationelectron cooler calibration voltage - frequency[TABLE border="1"]
SetVoltage (DeltaU) | MeasVoltage | freq
| Current 
  
  99   Tue May 31 17:22:09 2022 Max, Carsten, Danyal, Rodolfo, WilfriedGeneralchange E-cooler current I_e = 50 mA
At 17:15 we changed again the E-cooler current
I_e = 50 mA  
  
  98   Tue May 31 15:19:58 2022 Max, Carsten, DanyalGeneralscans for different E-cool currents
until 15:15 we have measured with I_e = 100
mA (3 loops per file) 
  
  97   Tue May 31 03:18:52 2022 Patrick, KonstantinLaserLaser timingThe final timings are (in bins +-1):

PD NO: 103
  
  96   Mon May 30 23:18:06 2022 Carsten, Rodolfo, Konstantin, Patrick, Ragan, Ken, Kristian, Max, DanyalRunsRuns shifts 31.05.These are the first runs with 208Bi.

[TABLE border="1"]
 2022-05-31_particles.png 
  94   Mon May 30 21:52:08 2022 Wilfried, Danyal, David, RodolfoGeneralPosition of T-ScrapersWe have determined the position of the H-like
208Bi ion beam using the T-Scrapers. The
position actually did not change in comparison
 MRC_208Bi_30-05-2022-10Uhr.png 
  93   Mon May 30 20:58:26 2022 CarstenAcceleratorNew Settings for 208Bi Beam Old SetParameters.C and old SetConditions.C
were saved as SetParameters_209.C and SetConditions_209.C
  