27
Thu Jun 6 19:47:01 2024
Carsten
DAQ
Exchange of Mesytec CFD/shaper - noise on signal lines from ESR magnets
Jan exchanged the Mesytec CFD/shper since
it could not be "remote controlled" anymore.
The new one has different shaping times and
67
Thu Jun 13 14:56:09 2024
Stefan Schippers
Accelerator
Estimated beam lifetime: About 150 s
Estimate of storage lifetime using my code
'hydrocal':
3
Thu Apr 25 16:34:05 2024
Rodolfo
Laser
Efficiency of Fluorescein27
The figure below shows the efficiency of Fluorescein27
vs. Wavelength. Each point was averaged over
500 laser shots.
28
Thu Jun 6 19:51:11 2024
Carsten
Accelerator
ESR crew left after persisting problems with ESR magnets
No beam today.--.
18
Wed Jun 5 14:17:36 2024
Carsten
Accelerator
Distance Cooler Detector
Calculation from Helmut Weick (copied from
E142)
Distance e-cooler to particle detectors chamber:
76
Fri Jun 14 13:14:29 2024
Konstantin, Bernhard, Peter, Lukas
General
DAQ crashes at :10
10 Minutes past a full hour (XX:10) the windows
PCs (sometimes) loose connection.
This causes the labview server & the laser
10
Sat Jun 1 18:14:01 2024
Carsten
Analysis
DAQ and analysis directories
[U][B]DAQ1 (original):[/B][/U]
-user atplaser
-runs on lxg1297
74
Fri Jun 14 11:44:23 2024
Carsten Brandau
Accelerator
Cooling Time in SC7 increased from 9s to 12s
Cooling Time in SC7 increased from 9s to 12s
68
Thu Jun 13 18:03:36 2024
Afternoon shift
Runs
Continuation: First scans
[TABLE border="1"]
Time | Part. Det. Int | ESR-intensity| cooler-HV
| LMD-DAQ1 Files | LMD-DAQ2 Files | scan
12
Sat Jun 1 19:00:57 2024
Carsten
DAQ
Change of (offline) frequency for common stop (CS) of VUPROMs (and 2nd TDC) and scaling factor
Temporarily, for tests of the second DAQ I
changed the frequency from the frequency
generator and scaling factor that is used
55
Wed Jun 12 22:48:55 2024
Carsten
Beam Halo
The seamingly short live time reported in
[URL=https://elog.gsi.de/esr/E0052/53]entry
53[/URL] is due to a halo from a different
77
Fri Jun 14 14:44:51 2024
Afternoon shift
Runs
Afternoon shift
Pizza shift
[B]the scan direction is from higher wavelength
14
Sun Jun 2 00:01:46 2024
Carsten
DAQ
25ps TDC CAEN V1290N DAQ2 lead to crash in DAQ2 due to a hardware issue
On the CAEN V1290N TDC the piggy board for
the lower 8 channels is not fixed well to
the motherboard.
59
Thu Jun 13 10:32:29 2024
Konstantin
Accelerator
(Proper) Cooler settings
We change the acceleration voltage of the
electron cooler and observe the platform
high voltage and the count rate at the particle
Goto page